Showing results: 6046 - 6060 of 6618 items found.
-
40-610-021-S-2/32/1 -
Pickering Interfaces Ltd.
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
60-553-007 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
60-552-030 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
40-640A-022-94/1 -
Pickering Interfaces Ltd.
The 40-640A-022-94/1 is a 94-channel, 1-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
40-675B-002-24/8 -
Pickering Interfaces Ltd.
The 40-675B-002-24/8 (PXI) and the 42-675B-002-24/8 (PXIe) are 24-channel, 8-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
40-670A-021-10/8 -
Pickering Interfaces Ltd.
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-615-022-2/80/1 -
Pickering Interfaces Ltd.
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration. Connections are made via a front panel 200-pin connector.
-
40-675B-002-49/4 -
Pickering Interfaces Ltd.
The 40-675B-002-49/4 (PXI) and the 42-675B-002-49/4 (PXIe) are 49-channel, 4-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
60-552-922 -
Pickering Interfaces Ltd.
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
40-670C-022-99/2 -
Pickering Interfaces Ltd.
The 40-670C-022-99/2 is a 99-channel, 2-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-610-021-S-1/64/1 -
Pickering Interfaces Ltd.
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
40-610-022-2/32/2 -
Pickering Interfaces Ltd.
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
40-670C-022-10/16 -
Pickering Interfaces Ltd.
The 40-670C-022-10/16 is a 10-channel, 16-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Pickering Interfaces Ltd.
The 40-615A-007 is a 2-bank, 80-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Pickering Interfaces Ltd.
Pickering's LXI Microwave Matrix is a 2U full rack width unit that provides a compact microwave switching solution for automatic text equipment (ATE) systems. The matrix is fully configured to the specified dimensions with no extra cabling needed; saving users the cost and time of creating matrices from individual components.