40-527A-001 - Pickering Interfaces Ltd.
The 40-527A, is a PXI single-pole 64x2 matrix and is part of a range of matrices supporting 128 crosspoints. All models use gold-plated contact electromechanical relays.
-
40-137-001 - Pickering Interfaces Ltd.
These PXI Power Relay Modules are suitable for applications requiring power relay switching with high density. This version features 5A current and voltage to 110VDC/250VAC, they are configured as Single Pole Single Throw (SPST). Connections are made via front panel mounted 37 or 78-pin D-Type connector. Along with this 16 x SPST, 5A version, the range also includes a 39 x SPST, 2A version and a 32x SPST version - go to Also in the Range above to learn more. Typical applications will be found in Automotive Test, Aerospace Test and Power Cell Test applications.
-
40-568-107 - Pickering Interfaces Ltd.
The 40-568 PXI Matrix BRIC provides a range of high density matrix modules able to switch up to 2 Amps or 200VDC/140VAC. The 40-568 BRIC modules are available in 2, 4 or 8-slot PXI sizes to suit most high performance PXI Matrix requirements, constructed using high quality electromechanical relays for high switching confidence.
-
40-560A-021-184X4 - Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-110-021 - Pickering Interfaces Ltd.
The 40-110/115 range of switching modules are available in both Changeover (SPDT) and Normally Open (SPST & DPST) configurations. Connections are made via a front panel 96 pin male micro-D connector. General purpose reed relays are used for the construction of small switching networks or for slaving up to larger switches.To simplify inter-relay wiring, interconnection points are built onto the circuit board thus easing the construction of complicated wiring.
-
40-561A-122-120X16 - Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-220A-802 - Pickering Interfaces Ltd.
The 40-220A series of breadboard modules allow the user to construct their own circuit in situations where a suitable PXI module is not available. For example when it is required to integrate a non-switching function into a PXI chassis. Typical applications include: Creating custom circuitry that can be housed in on a 3U board, or to build special one-off switching modules.
-
40-575-001 - Pickering Interfaces Ltd.
The 40-575/576/577/578/579 are a range of high density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
40-560A-121-161X16 - Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-567-107 - Pickering Interfaces Ltd.
The 40-567 PXI Matrix BRIC provides a range of high density matrix modules able to switch up to 2 Amps or 100VDC/70VAC. The 40-567 BRIC modules are available in 2, 4 or 8-slot PXI sizes to suit most high performance PXI Matrix requirements, constructed using high quality electromechanical relays for high switching confidence.
-
40-202-001 - Pickering Interfaces Ltd.
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
40-577-001 - Pickering Interfaces Ltd.
The 40-575/576/577/578/579 are a range of high density matrix modules able to switch up to 2 Amps or 300VDC/250VAC. They are constructed using high quality electro-mechanical relays for high switching confidence.
-
40-565B-102-116X8 - Pickering Interfaces Ltd.
These modules are 2 Amp high-density large PXI matrix modules with the ability to switch up to 2 Amps at 150VDC/100VAC. These 2A switch matrix modules are available in 2, 4 or 8-slot PXI sizes for most high-performance PXI matrix requirements. Constructed using quality electro-mechanical relays for high switching confidence.
-
40-561A-122-60X16 - Pickering Interfaces Ltd.
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
40-562B-121-528X4 - Pickering Interfaces Ltd.
The 40-562B-121-528X4 is a high density BRIC8 matrix module with a size of 528x4 with 1-pole switching. It is part of a range of BRIC matrices available in 2, 4, 8 or 12-slot formats to suit high performance PXI matrix requirements and is constructed using instrumentation quality reed relays.