Showing results: 6271 - 6285 of 6518 items found.
-
40-615A-013 -
Pickering Interfaces Ltd.
The 40-615A-013 is a 20-bank, 4-channel, 1-pole (SP4T) MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
60-554-028 -
Pickering Interfaces Ltd.
A high-density single pole matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
40-610A-003 -
Pickering Interfaces Ltd.
The 40-610A-003 is a 2-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
40-610A-012 -
Pickering Interfaces Ltd.
The 40-610A-012 is a 1-bank, 64-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
60-553-002 -
Pickering Interfaces Ltd.
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
40-670A-021-99/1 -
Pickering Interfaces Ltd.
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-615A-016 -
Pickering Interfaces Ltd.
The 40-615A-016 is a 4-bank, 20-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
40-610A-008 -
Pickering Interfaces Ltd.
The 40-610A-008 is a 1-bank, 64-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
40-670C-022-5/32 -
Pickering Interfaces Ltd.
The 40-670C-022-5/32 is a 5-channel, 32-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
40-640-022-47/2 -
Pickering Interfaces Ltd.
This series of high density multiplexer modules feature a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector. It may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available for this 1-pole version).
-
40-547-001 -
Pickering Interfaces Ltd.
Model 40-547-001 is a high density single 1-pole 10x8 power matrix module. It is also available in dual 10x4, dual 10x4 or single 20x4 relay formats: Typical applications include power routing in Functional ATE systems, specifically automotive electronics, for example testing of Engine Management Units.
-
40-610-022-8/8/2 -
Pickering Interfaces Ltd.
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
40-615A-006 -
Pickering Interfaces Ltd.
The 40-615A-006 is a 5-bank, 16-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
40-640A-022-47/2 -
Pickering Interfaces Ltd.
The 40-640A-022-47/2 is a 47-channel, 2-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
40-615-022-10/8/2 -
Pickering Interfaces Ltd.
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.