40-780B-533-E-LA - Pickering Interfaces Ltd.
The 40-780B-533-E-LA (PXI) and 42-780B-533-E-LA (PXIe) are triple latching SPDT 26.5 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
40-533A-022 - Pickering Interfaces Ltd.
Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109 operations to give maximum switching confidence with long life and stable contact resistance.
-
40-331-001 - Pickering Interfaces Ltd.
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
Pickering Interfaces Ltd.
Take advantage of the latest high-performance, low-cost desktop PCs for control of your PXI system.
-
40-553A-011 - Pickering Interfaces Ltd.
The 40-553A-011 is a high current 6x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
40-855-212-M62.5 - Pickering Interfaces Ltd.
Fiber Optic MEMS Switching cards available in many high density formats with a choice of five different connector styles to suit most applications
-
40-855-442 - Pickering Interfaces Ltd.
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
Pickering Interfaces Ltd.
The USB Hub's output ports can be connected or disconnected programmatically to simulate the mechanical connection of a USB device to the module. Additionally, each port has the ability to connect and disconnect the power and data paths separately, enabling the simulation of various connection faults. Take a look at our article, "Bringing USB to the PXI Test Environment" .
-
40-263-102 - Pickering Interfaces Ltd.
The 40-263-102 is a 20-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
40-850-414 - Pickering Interfaces Ltd.
The 40-850-414 4-channel multiplexer is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
40-190B-501 - Pickering Interfaces Ltd.
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-882-003 - Pickering Interfaces Ltd.
A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
41-620-003 - Pickering Interfaces Ltd.
The 41-620 is a compact 3 channel function generator provided in a PXI 3U single slot module. It is capable of generating sine waves to 10MHz with 48-bit frequency resolution referenced to the 10MHz PXI clock or to an external standard. The 41-620 can generate arbitrary waveforms loaded into the internal 256k memory, allowing the function generator to emulate many waveform types, including the typical waveforms of automotive and aerospace sensors.
-
Pickering Interfaces Ltd.
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
40-834-001 - Pickering Interfaces Ltd.
The 40-834-001 is a 75 Ohm 8 to 1 RF MUX with 1 bank in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40-834 minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.