Showing results: 2206 - 2220 of 6609 items found.
-
25600 -
Lisle Corp.
Small size allows easy use even in the tightest places. Quickly test low voltage up to 12 volts. Alligator clip grounds tester.
-
BV0023B -
Keysight Technologies
The PathWave BenchVue USB modular SMU pro software configures voltage and current source, range and limit for each SMU channel and log unrestricted data.
-
DAQM903A -
Keysight Technologies
DAQM903A 20 Channel Actuator/GP Switch Module for DAQ970A and DAQ973A. 20 independent single-pole, double-throw (SPDT) relays with switching voltage up to 300 V.
-
SG5201 -
Shanghai Jiuzhi Electric Co., Ltd.
This instrument offers a complete set of functions to measure and detect effectively all parts of current in an insulation system. The instrument can supply an output power of 5W and a test voltage of up to 5000V and therefore measure insulation resistances up to 1TOhm. Additionally step-up voltage measurement, withstand voltage measurement, AC/DC voltage and frequency measurements up to 600V can be performed.
-
M9186A -
Keysight Technologies
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Nanjing ELIKE Meter Co, Ltd.
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
Techimp HQ S.r.L
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
72-8110 -
Tenma
The 72-8110 is a compact switch mode Power Supply features a very compact footprint that makes it an ideal match for portable communications equipment. Its 50% duty cycle surge rating is comes in handy in demanding transmitting situations. It is also perfect for two-way radio (including HF) and audio equipment including auto sound and multimedia systems. This fixed voltage switch mode power supply is designed with high RFI stability and is especially suitable for two-way radio and communications equipment. Constant current circuitry is used for overload, short-circuit and over-temperature protection. Output current and voltage drop to a safe level when any fault occurs. This power supply also has over voltage protection to prevent connected equipment from damage.
-
72-7730A -
Tenma
Digital multimeter is a 20,000 counts and 4-1/2 digits with steady operation. The meter can measure AC voltage and current, DC voltage and current, resistance, capacitance, temperature frequency, diodes, continuity, 4 to 20mA loop, Max/Min, relative mode but also has data store, data recall, AC true RMS, AC+DC, low battery display, double display backlight, automatic power off and full overload protection.
-
Acromag, Inc.
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
LBA Group, Inc
Lighting chokes are used to pass tower lighting voltages across the base insulator of a series-fed tower without appreciably altering the tower impedance. LBA TC-300 general purpose tower lighting chokes are provided for three wire 110/220 VAC circuits. Maximum current is 25 amps. These chokes are rated for peak base voltages to 10,000 volts, and present a typical reactance of +j5000 ohms at 530 kHz. Bypass capacitors are provided on each winding.
-
Pickering Interfaces Ltd.
Programmable RF Attenuators – accurate DC to 3GHz programmable attenuator has a 1dB step resolution, allowing it to adjust signal amplitudes for optimum measurement by other devices.Solid State Programmable RF Attenuators – available in triple or hex formats with bandwidths between 10MHz and 6GHz.High Voltage Attenuators – provide a convenient way of attenuating high voltage low frequency signals to levels that can be captured by other PXI devices without risk of damaging them.
-
YAV91074 -
6TL Engineering
The YAV90074 module contents 48 SPDT Relays independent. Each relays PCB contact track is shielded individually in order to handle very low voltage signals and audio signals with extremely low crosstalk. The build-in power supply includes two extra filters to reduce the DC voltage ripple to the relay coils; the control tracks have been drawn in quadrature with signal ones, reducing the inductive coupling produced by the transient current.
-
DT3 -
North Atlantic Industries
The DT3 module (the enhanced version) feature 4 independent, high current, isolated, programmable channels that can be used for input voltage measurements (±100 V), or as a bi-directional current switch (up to 3 A per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection.
-
3206G -
Radian Research, Inc.
The Model 3206G Meter Warm-Up Station for AMR Modules has been specifically designed for meters that utilize the DCSI TWACS™ power line carrier communications module. Additionally, this versatile unit includes voltage output and voltage input connections that allow you to test additional brands of power line carrier modules when using the manufacturer’s supplied module. The Model 3206G can even be used as a simple meter warm-up station.