  • 60A True RMS AC Clamp Meter + NCV

    Extech MA61 - Extech Instruments Corporation

    The MA61 is an AC current clamp with NCV voltage detector and full overload protection. Manual ranging clamp meter with three Current ranges and AC/DC voltage to 600V. The 6000mA range allows for low current measurements that may be used in the automotive industry. Unique VFC (variable frequency control) mode helps troubleshoot and diagnose HVAC applications that are variable frequency driven. The MA61 also features resistance, capacitance, frequency, diode and continuity measurements as well as data hold low battery indicator, and auto power off functions. Complete with test leads, carrying case, and two AAA batteries.

  • 60A True RMS AC/DC Clamp Meter + NCV

    Extech MA63 - Extech Instruments Corporation

    The MA63 is an AC/DC current clamp with NCV voltage detector and full overload protection. Manual ranging clamp meter with three Current ranges and AC/DC voltage to 600V. The 6000mA range allows for low current measurements that may be used in the automotive industry. Unique VFC (variable frequency control) mode helps troubleshoot and diagnose HVAC applications that are variable frequency driven. The MA63 also features resistance, capacitance, frequency, diode and continuity measurements as well as data hold low battery indicator, and auto power off functions. Complete with test leads, carrying case, and two AAA batteries.

  • Single-Functional Testers

    3122 - Metrel d.d.

    The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains integrated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS / FAIL lights and help screens for each measurement make the handling of the instrument easy and clear. All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Fiber Optic Transmission Systems

    B-1020-B - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation has developed a HV compact analog fiber optic transmitting and receiving system, with optional over-voltage limiting, designed to drive instrumentation from a DC to 1MHz signal source. The system is available with optional multiple input and output ranges of ±0-1V PK, 0-5V PK to 0-10V PK. It will also operate in conjunction with Ross Engineering Corporation’s high accuracy high voltage wideband voltage dividers, which are useful from DC to over 10MHz up to 1,000,000V PK at 0.01% to 3% accuracy. Transmitters and receivers can be powered by either AC or DC.

  • Battery Discharge and Capacity Testers

    HD Power Test Equipment Co.ltd

    HDFD Battery Discharge Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current. When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.This tester system is simple, safe and accurate for monitoring voltage of cells adopting wireless connection.

  • Current-Voltage Measurement System

    Sciencetech, Inc.

    Sciencetech''s IV Testers are electrical current-voltage measurement systems used to characterize photovoltaic cell performance. This current-voltage tester works by sampling various current versus voltage combinations of the photovoltaic cell with a variable impedence load.This IV Test system can measure electrical power from photovoltaic cells up to 20W. The voltage envelope is limited to 20V and the current to 1A. A higher power version, up to 60W, is available. In general, the limitation on this model is the 1A current limit: if your solar cell generates more than 1A, we recommend upgrading to the 60W version.

  • 8 Function True RMS Multimeter

    Extech EX360 - Extech Instruments Corporation

    The EX360 is a Compact Electrical True RMS MultiMeter with a Built in Non Contact Voltage Detector. Featuring highly accurate True RMS measurements, LoZ for the prevention of false readings caused by ghost voltages, .5% basic accuracy, a 1000V AC/DC volt range, resistance up to 40MΩ, continuity beeper with visual alert, smart data hold, peak hold, auto power off with disable, relative mode for capacitance zero and offset adjustment. Additionally, the EX360 excels in frequency and capacitance measurement. Complete with test leads, 9V battery, holster with tilt stand and built-in magnet.

  • Three Phase Power Analyzer

    Model TFT780 - Gopal Electronics

    Three Phase Power Analyzer PA700TFT is multi-range power Analyzer with basic 0.05% R+R accuracy. 8 range of voltage, 8 range of current and total 64 range of power and power factor gives more accurate result at low power factor. It has waveform mode to check the waveform of voltage and current. As well it has B/H curve mode where user can check live b/h curve of the transformer under test. The gap less four-quadrant power measurement technique gives better accuracy at distorted waveforms or AC drive (VFD) operated power supply.

  • IVTS In-Vehicle Test Set

    LXinstruments GmbH

    The in-vehicle test set was developed to successively measure several active RF amplifiers installed in the vehicle as well as different antenna structures. It offers the possibility to connect 12 DUTs. The DUTs can be connected to an external spectrum analyser via a 1 to 12 RF multiplexer. Each DUT can be individually switched and supplied with an adjustable voltage via a bias-tee integrated in the system. The individual bias voltages and currents are recorded by the IVTS and can be called up on an interactive control panel or via Ethernet and SCPI commands. The complete system can be powered by rechargeable battery and can be operated either via Ethernet, fibre optics or WLAN.

  • PXIe-4339, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    783531-01 - NI

    25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4339 is a universal bridge input module ideal for test cell installations requiring both accuracy and flexibility. Completely configurable through software, each channel can take bridge-based measurements and direct voltage measurements. Eight input ranges in ratiometric mode and four in voltage mode accommodate a wide variety of sensor types for your changing application needs. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, programmable excitation, Transducer Electronic Data Sheet (TEDS) support, and digital filtering.

  • PXIe-4322, 16-Bit, 8-Channel, 250 kS/s Ch-Ch Isolated PXIe Analog Output Module

    782878-01 - NI

    16-Bit, 8-Channel, 250 kS/s Ch-Ch Isolated PXIe Analog Output Module—The PXIe‑4322 is a channel‑to‑channel isolated analog output module with integrated signal conditioning. The device provides accurate, simultaneous dynamic voltage and current outputs. By combining signal conditioning and D/A converters on the same device, the PXIe‑4322 isolated analog output module delivers a smaller footprint and higher measurement performance. In current mode, the module operates in all four quadrants, so you can both sink and source current. Isolation and higher voltage and current outputs make this module ideal for automotive applications.

  • Digital Insulation Mult-Meter

    8010 IN - Standard Electric Works Co., Ltd

    ● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1

  • Portable Test Systems

    ZERA GmbH

    We refer to test meters with an integrated source as test systems. Test systems are particularly useful when you need custom current and voltage values ​​when testing meter installations, but only want to use a single device.

  • Data Acquisition Recorders & Loggers

    B&K Precision Corporation

    B&K Precision offers a full range of data acquisition recorders & loggers for measuring parameters such as voltage, temperature, current, resistance, frequency, and pulse. From high speed recording with deep memory, to long battery life for portability.