Showing results: 2146 - 2160 of 6611 items found.
-
Elcometer 236 -
Elcometer Limited
The Elcometer 236 Holiday Detector provides high voltage porosity testing to detect pits, flaws, holes, etc. in a wide variety of non-metallic coatings.
-
SE-6000/6010 -
IWATSU Electronic Co., Ltd.
Performs waveform measurements with high resolutions and in safe manner under high voltage environment in systems that isolate Input/output terminals through optical insulation
-
PDCheck -
Techimp HQ S.r.L
PDCheck is a compact, stand alone, global diagnostic system for the condition assessment of medium and high voltage electrical systems, based on the detection and analysis of PD
-
Chroma Systems Solutions, Inc.
Delivers pure, instrument grade AC power at very low cost with output voltage from 0 to 300VAC, and frequencies from 15 to 1000Hz
-
KT-2G/MD-2G -
Ketai instrument (kunshan) Ltd.
The large LCD screen displays the measurement response quickly, and the low voltage displays the data retention function. The moisture measurement range is 10%-40%
-
SK-3002/SK-3003/SK-3005 -
Kaise Corporation
250V/500V (SK-3002), 500V/1000V (SK-3003/3005)Drop-proof taut band meter .AC voltage measurement and battery check.Approx. 3 minutes continuous measurement.
-
HM21 -
Jandel Engineering Limited
The Jandel HM21 Test Unit has six constant current settings between 100nA and 10mA, and can be used to measure voltages from 0.01mV to 1250mV.
-
AXS7720 -
VX Instruments GmbH
Extremely low noise with linear output stageVery fast rise and fall timesProgrammable current pulseIntegrated current measurement unitIntegrated voltage measurement unit
-
Megger Group Ltd.
A selection of voltage detectors, proving units, test leads, certificate books and a DVD, which make it that bit safer and easier to get the job done.
-
Osborne Transformer Corp.
Osborne Saturable Reactors are designed to provide a variable output voltage through the use of variable impedance connected in series with a constant impedance load. Each saturable reactor’s impedance is determined by the application of DC power to a control winding. As the level of power supplied to the control winding is increased, the saturable reactor becomes more saturated. This reduces the impedance of the AC gate winding, and increase the amount of the supply voltage that is transferred to the load. Conversely, as the power is reduced to the control winding, the reactor becomes less saturated, the gate winding has more impedance and less of the input voltage is provided to the output impedance. This approach provides excellent quality, reliability, and control when designed to match the requirements of a specific application.
-
72-6628 -
Tenma
The 72-6628 is a Triple Bench Power Supply with adjustable current control and galvanized steel case. The DC regulated power supply is a completely solid state, compact, well regulated, constant voltage power supply suitable for service field, hobby, laboratory and testing use. It provides three different voltages output for different. Overload and short-circuit protection, prevent the unit from overload and short circuit. When the unit is under the condition of overload or short circuit, the output current will be limited. Independent 5V, 12V easy snap-on output terminals to make it easy to use for TTL and CMOS circuit testing. The grounding of the output terminals is independent that the output can be connected in series to make a higher output voltage.
-
MOSTS6 -
Holding Informtest
*MOSTS6 is the first Russian instrument (oscilloscope) with a direct sampling rate (8bit ADC), 5 Gigasemp / s per channel. M-module MOSTs6 is designed to work as a part of information measuring systems based on the VXI bus magister as a digital oscilloscope. The M-module is made in the form of a triple-width mezzanine, is installed on a mezzanine carrier and is connected to it via a local information highway.*MOSTS6 is designed to convert instantaneous voltage values of an electrical signal into a digital code, measure instantaneous voltage values, measure time intervals between two instantaneous voltage values through two independent channels.MOSC6, according to the conditions of use, meets the requirements for measuring instruments of group 3 in accordance with GOST 22261-94.
-
E3640A -
Keysight Technologies
Output ratings (@ 0C to 40C)Range 1: 0 to 8 V / 3 ARange 2: 0 to 20 V / 1.5 AProgramming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHzNormal Mode Voltage: <5 mVpp / 0.5 mVrmsNormal Mode Current: <4 mArmsCommon Mode Current: <1.5 uArmsReadback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
CAEN S.p.A.
- From 12 to 48 independently controllable High Voltage channels- 0 ÷ 500 V output voltage (0 ÷ 250 V, A1519B and A1619 only)- Maximum Current 0.5, 1, 10 mA or 1 mA/100 μA (dual range boards)- Individual Enable (A151x only)- Either DB37, DB25, Radiall Multipin or SHV connectors- Available with either positive, negative or mixed polarity- Up to 20 nA, 100 pA current set / monitor resolution- Up to 10 mV / 1 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mVpp- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Full Floating (A151x, A1612, A1619)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in overcurrent condition- Specific design for double side silicon detector (A151x)
-
Model 19032/19032-P -
Chroma ATE Inc.
Electrical Safety Test (EST) Analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.