Showing results: 856 - 870 of 6611 items found.
-
PK-HVA-02 -
Teledyne LeCroy
Replacement Pincer Clips for High Voltage Differential Probe
-
PK-HVA-05 -
Teledyne LeCroy
Replacement Spade Terminals for High Voltage Differential Probe
-
865685-01 -
NI
NI-9220, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9220, cDAQ-9171, and cRIO-9940 includes the NI-9220 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9220 features 16 channels and 16 simultaneous differential analog inputs with 250 Vrms CAT II or 60 VDC CAT I isolation. Additionally, you can use the NI-9220 to generate 3.2 MB/s of data at the maximum sampling rate.
-
-
-
ISL60002 -
Renesas Electronics Corp.
The ISL60002 FGA™ voltage references are very high precision analog voltage references fabricated on Renesas' proprietary Floating Gate Analog technology and feature low supply voltage operation at ultra-low 350nA operating current. Additionally, the ISL60002 family features guaranteed initial accuracy as low as ±1.0mV and 20ppm/°C temperature coefficient. The initial accuracy and temperature stability performance of the ISL60002 family, plus the low supply voltage and 350nA power consumption, eliminates the need to compromise thermal stability for reduced power consumption making it an ideal companion to high resolution, low power data conversion systems.
-
Premier Electrosystems
The typical use of high voltage testing is to confirm performance. The high voltage tests are included in type and routine tests to meet the required IS standards, quality and reliability. Some of them are insulation resistance tests, dielectric type tests, lightning and switching impulse tests, partial discharge measurement, etc. Premier's high voltage tester checks the insulation between line to earth, neutral to earth, primary to earth, secondary to earth and between primary & secondary.
-
YGZQ Series -
Shanghai Jiuzhi Electric Co., Ltd.
Over Voltage Cycle Test System is the type test, repeated over voltage from lowest rated temperature to the ambient temperature to improve the dielectric performance for the shunt capacitor above 10kV. In the recent year, this test is more popular to done in the modern factory.
-
Neutronics Manufacturing Co.
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.
-
SGMF(T) Series -
Shanghai Jiuzhi Electric Co., Ltd.
Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument transformers, GIS, GIL, switchgears and etc after they are installed onsite and for purposes of diagnostics in asset management up to 900kV/10A.
-
KM 6213AIN -
Kusam Electrical Industries Limited
• The KM 6213A IN is the KUSAM-MECO premium model of High Voltage Digital Insulation Resistance Testers.• The KM 6213A IN has new added features with a low consumption High Performance processor.• It displays results much faster and has more advanced features.• The KM 6213A IN has Automatic Polarization Index and Dielectric Absorption Ratio Calculations.• Results are displayed on the new High Contrast LCD. It’s mounting angle makes it more readable for all users, in different working conditions.• The user’s manual reflects the new features and added benefits of this instrument.• It has Auto-Off, Auto-Stop, EnerSave™ and is a non destructive tester.• Once you start the tester, it waits for your selection. You can go up and down in voltage to select the voltage at which you want to test the insulation. Once you have selected that voltage, you need to connect the test leads to the Insulation Tester to measure. Then it measures voltage to ensure there is no voltage present on the equipment under test. If there is a voltage present, it will warn you to disconnect the circuit before proceeding. If it’s free of any voltage, then you can proceed with the testing. This ensures that no damage is done to the Insulation Tester KM 6213AIN.• One of the new innovation on this tester is also the way the new unique calibration process works. It’s fully digital, has no moving parts and does not require expensive and complicated jigs or computers systems to be calibrated. It’s cheaper to maintain than any other Digital HV Insulation tester on the market today. The KM 6213AIN is supplied standard with our Premium test Leads Kit, the AL-50.
-
40-330-003 -
Pickering Interfaces Ltd.
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-
40-330-002 -
Pickering Interfaces Ltd.
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-
40-330-001 -
Pickering Interfaces Ltd.
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-