Showing results: 2386 - 2400 of 6622 items found.
-
LX-PDU-03-32A-NA -
LXinstruments GmbH
This means that devices can be supplied with both mains voltage and DC voltage. With the soft-on-off function, the PDU can be controlled remotely via remote buttons and other potential-free contacts. By using the PDU, you simplify the ordering process with only one device required.The device is extremely flexible thanks to its modular configuration. Comprehensive documentation through operating instructions, wiring plans and CE declaration of conformity. Due to the predominantly pluggable connections, integration and installation are extremely easy. Accessories, options and extensions are available.
-
19036 -
Chroma ATE Inc.
Chroma 19036 is the industry's first wound component electrical safety test (EST) analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.
-
SP-Cap™ -
Panasonic Industrial Devices Sales Company of America
Panasonic’s industry leading SP-Cap™ Polymer Aluminum Capacitors, are Surface-Mount (SMT) Capacitors that utilize a conductive polymer as their electrolyte material in a layered aluminum design. SP-Cap Capacitors are primarily used as input and output Capacitors for DC/DC converters due to ultra-low ESR values, high voltage options and the ability to withstand high reflow temperatures. These Capacitors are free from temperature drifts, offering capacitance values up to 560µF and voltage values ranging from 2V to 25V.
-
PFK-105 -
Prostat Corporation
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
LQ6324T -
Aplab Limited
- Low cost general purpose laboratory bench unit.- Fully protected against overload and short circuit.- Three independent outputs electrically isolated from each other.- 5V/5A with over voltage crowbar protection for digital ICs.- Electrically floating outputs up to 500V DC w.r.t. ground.- Compact modular construction.- Precise regulation, low ripple and noise for both constant voltage and constant current operation.- Quality components and conservating ratings for high reliability and long life.
-
40-131-201 -
Pickering Interfaces Ltd.
These are low cost, general purpose electromechanical relay cards capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.
-
40-131-001 -
Pickering Interfaces Ltd.
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
HSL-DI16DO16-M-NN -
ADLINK Technology Inc.
- Input voltage: ±40 V (Max)- Output switching capacity: Single channel 500 mA; all channels 60 mA at 24 VDC- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ±10 mA (Max) , ±12.5 mA (Peak)- 16-CH digital input and 16-CH digital output. "NN" type for NPN sinking type sensor input or dry contact and NPN sinking type output- Slave ID consumption: 1
-
HSL-DI32-M-N/HSL-DI32-M-P -
ADLINK Technology Inc.
- Slave ID consumption: 2 consecutive from odd- "N" type for NPN sinking type sensor or dry contact; "P" type for PNP sourcing type sensor or wet contact- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ± 10 mA (Max), ± 12.5 mA (Peak)- Input voltage: ± 40 V (Max)- LED indicator: Power, Link and Input status- Power supply: +10 V to +30 VDC
-
EX-R Series -
Aim-TTi
Single outputs, 35V/5A, 18V/10A, 42V/10A, 20V/20ADual or triple outputs, 35V/4AIndependent digital voltage and current meters for each output with 4 digit resolutionSwitchable local or remote sensingConstant voltage or constant current operationVariable 1.5 - 5.0V auxiliary output at 5A (EX354RT)Compact design uses less bench spaceSilent fan-free cooling (not EX202R/EX4210R)DC output switches, automatic mode indicationRS232 or USB controlled models available (35V/5A single)Multi-mode dual model 2x(75V/2A) or 75V/4A or 150V/2A
-
PL Series -
Aim-TTi
ingle, dual or triple output modelsModels from 6V/8A up to 60V/1.5ALinear regulation - for the best performanceUltra-compact design - uses up less spaceTrue Analogue controls - for ease of useS-Lock function - instantly lock settingsV-Span function - customize the voltage rangeLow current range and current meter averagingDC output switches and "view limits" buttonSelectable remote sense terminalsIndependent, Isolated Tracking, Ratio Tracking and True Parallel modes on dual & triple modelsHigh current low voltage output on triple output model
-
Fairview Microwave Inc.
Fairview’s bi-directional amplifier models are designed for use in both commercial and military applications and will support any signal type and modulation format such as 3G and 4G telecom, WLAN, OFDM, DVB and CW/AM/FM. Fairview’s bi-directional amplifiers offer high power density, efficiency and linearity in small lightweight environmentally sealed packages with SMA connectors. These units also feature a quick-connect circular locking connector for DC and control functions and each design uses a single voltage supply with voltage regulation.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
HP860LED -
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
It is specially used to measure the photoelectric parameters of LED light distribution curve (LED light intensity distribution), beam angle, normal light intensity, forward voltage, reverse current, reverse breakdown voltage and other photoelectric parameters, in line with CIE pub.No. 127 condition A or B. This system achieves high-precision testing of the optical and electrical properties of LEDs, provides LED manufacturers with sufficient LED optical and electrical parameters, and makes the development and production of LEDs more effective and reliable.
-
Regatron AG
The latest multi-level inverter technology for high-resolution voltage / current patterns, allows the Simulator to cover the entire fundamental frequency range from DC up to 1000 Hz and up to 5000 Hz modulation bandwidth. A specialized multi-processor core prepares all relevant voltage / current shapes in real-time to ensure a very stable phase relationship and event timing throughout. A specialized multi-processor prepares all relevant voltage/current shapes in real-time to ensure a very stable phase relationship and event timing.