Showing results: 2401 - 2415 of 6650 items found.
-
PFK-105 -
Prostat Corporation
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
LQ6324T -
Aplab Limited
- Low cost general purpose laboratory bench unit.- Fully protected against overload and short circuit.- Three independent outputs electrically isolated from each other.- 5V/5A with over voltage crowbar protection for digital ICs.- Electrically floating outputs up to 500V DC w.r.t. ground.- Compact modular construction.- Precise regulation, low ripple and noise for both constant voltage and constant current operation.- Quality components and conservating ratings for high reliability and long life.
-
40-131-201 -
Pickering Interfaces Ltd.
These are low cost, general purpose electromechanical relay cards capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.
-
40-131-001 -
Pickering Interfaces Ltd.
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
HSL-DI16DO16-M-NN -
ADLINK Technology Inc.
- Input voltage: ±40 V (Max)- Output switching capacity: Single channel 500 mA; all channels 60 mA at 24 VDC- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ±10 mA (Max) , ±12.5 mA (Peak)- 16-CH digital input and 16-CH digital output. "NN" type for NPN sinking type sensor input or dry contact and NPN sinking type output- Slave ID consumption: 1
-
HSL-DI32-M-N/HSL-DI32-M-P -
ADLINK Technology Inc.
- Slave ID consumption: 2 consecutive from odd- "N" type for NPN sinking type sensor or dry contact; "P" type for PNP sourcing type sensor or wet contact- Photo couple isolation voltage: 2500 Vrms- Input impedance: 4.7 KΩ- Input current: ± 10 mA (Max), ± 12.5 mA (Peak)- Input voltage: ± 40 V (Max)- LED indicator: Power, Link and Input status- Power supply: +10 V to +30 VDC
-
EX-R Series -
Aim-TTi
Single outputs, 35V/5A, 18V/10A, 42V/10A, 20V/20ADual or triple outputs, 35V/4AIndependent digital voltage and current meters for each output with 4 digit resolutionSwitchable local or remote sensingConstant voltage or constant current operationVariable 1.5 - 5.0V auxiliary output at 5A (EX354RT)Compact design uses less bench spaceSilent fan-free cooling (not EX202R/EX4210R)DC output switches, automatic mode indicationRS232 or USB controlled models available (35V/5A single)Multi-mode dual model 2x(75V/2A) or 75V/4A or 150V/2A
-
PL Series -
Aim-TTi
ingle, dual or triple output modelsModels from 6V/8A up to 60V/1.5ALinear regulation - for the best performanceUltra-compact design - uses up less spaceTrue Analogue controls - for ease of useS-Lock function - instantly lock settingsV-Span function - customize the voltage rangeLow current range and current meter averagingDC output switches and "view limits" buttonSelectable remote sense terminalsIndependent, Isolated Tracking, Ratio Tracking and True Parallel modes on dual & triple modelsHigh current low voltage output on triple output model
-
Fairview Microwave Inc.
Fairview’s bi-directional amplifier models are designed for use in both commercial and military applications and will support any signal type and modulation format such as 3G and 4G telecom, WLAN, OFDM, DVB and CW/AM/FM. Fairview’s bi-directional amplifiers offer high power density, efficiency and linearity in small lightweight environmentally sealed packages with SMA connectors. These units also feature a quick-connect circular locking connector for DC and control functions and each design uses a single voltage supply with voltage regulation.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
HP860LED -
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
It is specially used to measure the photoelectric parameters of LED light distribution curve (LED light intensity distribution), beam angle, normal light intensity, forward voltage, reverse current, reverse breakdown voltage and other photoelectric parameters, in line with CIE pub.No. 127 condition A or B. This system achieves high-precision testing of the optical and electrical properties of LEDs, provides LED manufacturers with sufficient LED optical and electrical parameters, and makes the development and production of LEDs more effective and reliable.
-
Regatron AG
The latest multi-level inverter technology for high-resolution voltage / current patterns, allows the Simulator to cover the entire fundamental frequency range from DC up to 1000 Hz and up to 5000 Hz modulation bandwidth. A specialized multi-processor core prepares all relevant voltage / current shapes in real-time to ensure a very stable phase relationship and event timing throughout. A specialized multi-processor prepares all relevant voltage/current shapes in real-time to ensure a very stable phase relationship and event timing.
-
BDS-Pro -
Eagle Eye Power Solutions
Eagle Eye's BDS-Pro Battery Monitoring System is designed to measure the aging status of up to 24 jars (or 24 cells) by measuring and recording: string voltage and current, as well as jar/cell voltage, internal resistance, connection resistance and temperature. The BDS-Pro Battery Monitoring Solution is the most accurate, user-friendly and economic solution for monitoring 24 jars (or 24 cells) systems using 1.0-16V batteries. Although the BDS-Pro is utilized in many industries, it is most frequently used in 24 cell, 48Vdc applications.
-
ITS-7025 -
Innovative Technical Systems
The ITS-7025 Temperature Sensor was developed to monitor the temperature of liquid-cooled klystron amplifiers. The sensor is designed to clamp directly to the cooling pipe and provide an analog voltage output from 0 to 10 VDC corresponding to 0 to 100 degC with 2 degC accuracy. Two analog outputs are provided; one for connection to a remote data acquisition system, and a second for local service monitoring. A single +28 VDC (other voltages available) powers the sensor which draws less than 100 uA.
-
Carl E. Holmes Company
Air Cooled SCR Controlled Power Supply, 50 KW, P/N 6037C1Input: 480 VAC, 60 Amps, 3 PH, 60 HzOutput: 6 to 10 VDC, 5000 Amps maxContactor and overload relay are installed for protectionStart / Stop capabilityEPO capabilityManual voltage control and current limitOutput voltage and current are displayed on the voltmeter and ammeterIndoor enclosure, 68″H x 65″W x 36″DAll input/output connections are inside the enclosuresEstimated weight: 1000 lbs.