Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 6046 - 6060 of 6622 items found.

  • Multi-Channel Gas Detection Controller

    MCA - Bacharach, Inc.

    The Neutronics MCA Multi-Channel Controllers are designed to accept up to 8 inputs. Primarily used with gas detector heads, the MCA controllers will also accept individual inputs from various types of monitoring instruments or transducers. A backlit LED display is provided to show the status of each channel, display graphs, and enable configuration of the unit (set alarm levels, program the output relay voting, etc.). The MCA can be programmed on-site by the user using the password protected configuration program. Each monitoring channel provides relay contact outputs along with 4-20mA and voltage outputs.

  • High-Performance Intelligent Pod for Corelis Boundary-Scan Controllers

    ScanTAP 4 & 8 - Corelis, Inc.

    Boundary-scan has proven itself time and again to be a truly versatile interface for structural test, embedded functional test, built-in self-test (BIST), software debug, and in-system programming. Supporting such diverse applications requires equipment with high-performance specifications and extended features.Corelis ScanTAP pods are designed for use with PCI-1149.1/Turbo and PCIe-1149.1 high-speed JTAG controllers. Featuring 4 & 8 independent Test Access Ports (TAPs), up to 80 MHz clock rates, and advanced TAP capabilities such as analog voltage measurement, the ScanTAP family of intelligent pods is the ideal JTAG interface for high-performance environments.

  • Transient Suppression for Corelis JTAG Controllers

    TAP Protection Adapter - Corelis, Inc.

    Transient events such as Electrostatic Discharge (ESD), inductive switching, and lightning can damage electrical equipment, leading to costly repairs and test equipment down-time, reducing production capacity and increasing time-to-market.The Corelis TAP Protection Adapter is designed to enhance protection to any Corelis JTAG controller, shielding against harmful events using a combination of electrical defenses.The compact adapter features series resistors and transient voltage suppressor (TVS) diodes to mitigate damage to the JTAG controller. Protect your investment and enjoy peace-of-mind with the TAP Protection Adapter.

  • Milliohm Meters

    Chroma 16502 - Chroma Systems Solutions, Inc.

    With a basic accuracy of 0.05%, Chroma 16502 offers a 0.001mΩ ~1.9999MΩ wide measurement range. It provides measurement range with 4 1/2 digits resolution. The fast measurement time is 65 ms. It suits component evaluation on production line. Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurement. DC test current output mode is used to fasten measurement speed for inductive DUT. Dry-circuit test current output mode is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 20mV.

  • Bench Multimeters

    TM-8055 - Twintex Electronics Co., Ltd

    ★ 4 1/2 digits, bench type, large LCD of white backlight, easy to read★ With basic DCV, ACV, DCA, ACA, Ω, CAP, Hz, hFE, TEMP, Diode and Continuity measuring functions★ Voltage test range up to 1000V DC or peak-peak value AC, resolution up to 10uV★ Current test range up to 20A, auto polarity shift, data hold★ AC measuring adopts high accuracy true RMS, measuring broadband and AC+DC function

  • Mainframe or -E Expansion Chassis - Preconfigured Single or Two Pole Matrix Systems

    LXB/128-MF - Cytec Corp.

    These Chassis are preconfigured single or two pole matix systems. A single chassis can be a 16x8 matrix, two 16x4 matrices, a single 32x4 or a single 64x2 configuration. Chassis is modular so you may start with a smaller size and increase the configuration as your needs grow. LEDs on the front panel show switch and power status. A thumbwheel manual control is optional. Remote control is from 10/100 LAN, GPIB, RS232, USB or TTL. A variety of relays are available to handle almost any voltage. Connector options are BNC, Screw Terminal or Twinax.

  • 6U PXI Multi-Channel Analog I/O PXI Card

    GX3348 Series - Marvin Test Solutions, Inc.

    The GX3348 is a multi-channel analog I/O 6U PXI card which provides (3) programmable sources, a ground source connection, a pulse / square wave generator (A version only) and a 4 x 48 or 4 x 64 matrix - allowing the user to route the 3 sources, or ground to any of the 48 or 64 I/O channels. In addition, each I/O channel can be connected to a 16-bit A to D converter, providing DC voltage measurement capability for each channel. The module also offers (8) static digital I/O for controlling / monitoring a UUT's digital signals.

  • Static Sensor

    718 - SCS

    Portable Meter for Testing of Electrostatic FieldsMeasures surface voltage and polarity on objects up to ±19.99 kV at a distance of 1 inchSwitch Selectable Measurement RangesProvides readings from 0 to ±1.999 kV and 0 to ±19.99 kVChopper-Stabilized Probe TechnologyAllows for use in ionized environmentsDurable Dissipative Housing Design with Membrane SwitchesProtects meter from physical damage and minimizes wearLED Range FinderRed ranging lights help operator to place the meter at the correct distance from the object being measuredHold ButtonAllows the measurements to be retained for easy reading and extends battery life

  • TE-Metrology

    HIGHVOLT Prüftechnik Dresden GmbH

    The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components

  • Insulation Test Generator

    EMC Partner AG

    Screw connections on top of the generator, enable easy connection to the EUT. The MIG0603 is the ideal voltage insulation tester with a broad application range. The MIG "Modular-Impulse-Generator" is a flexible kit system, ready to quote tailored generators for special test applications. The MIG is a further innovative solution of EMC PARTNER AG to cover customers requests. The basic units are discharge modules (patent pending) which can be configured in serial or parallel, to offer an optimum solution for the customer need. The use of one type of discharge module guarantees a high reliability and a high qualit . Requires TC-MIG24 or CN-MIG24.

  • Gated Short Wave Infrared Camera System

    LIVAR® M506 - Intevac Imaging

    The LIVAR M506 Gated SWIR Camera System is ideal for covert operations and target identification, supporting lasers from 1.0 1.6 m. Cost-effective, compact and lightweight, this range-gated, two-dimensional imaging camera operates in the eye-safe Short Wave Infrared (SWIR) band, provides day and night coverage, and supports mounted and dismounted operations. The camera system includes the camera, High Voltage Power Supply (HVPS) and Thermoelectric Cooler Controller (TECC). An optional high-PRF version is available that allows the use of low-power, high-PRF diode lasers with the camera in accumulation mode.

  • LED Power Supply

    Shanghai Yiya Electronic Instrument Co., Ltd.

    1. High efficiency, low temp. movement(<18℃ in full load, superior stability. 2. Power supplies can be used in dry,damp and wet locations. 3. Built-in EMI filter & low ripple, reduce LED attenuation & increase life span. 4. Aluminum mental housing, easy for heat dissipation & ensure stability. 5. Automatic protection for over voltage, over current 6. 8-hour full load aging test, strict QC before delivery. 7. IP66/67 waterproof rating, suitable for outdoor & indoor application.

  • High-Voltage DC Power Supplies

    Excelitas Technologies Corp.

    Higher-voltage and Higher-power Supplies require more complex design solutions. The heat to be dissipated and installation infrastructure, plus choice of insulation system in a HVPS are driven by the output voltage and output power which ultimately dictates packaging. Typical insulation systems are based on air, dielectric oil, epoxy, RTV Silicone and even Sulfur Hexafluoride (SF6). The method of cooling is a factor as well, the choices often coming down to air, water or oil, depending on the platform design requirements. These applications require Excelitas' detailed understanding to help choose the best design solution.

  • High-voltage Testers

    Kharkovenergopribor Ltd.

    Operational safety and reliability of electrical equipment and cables directly depend on the dielectric strength of the insulation. Portable and mobile high-voltage testers from KharkovenErgoPribor Ltd. are used for acceptance and operational testing of substation equipment and cable lines, as well as for checking the reliability of personal electrical safety equipment. Our testers range is represented by test systems that allow conducting high-voltage tests with DC and AC voltage, testing polymer insulated cables with very low frequency, testing and locating faults in cable sheath, as well as performing the initial burning of insulation on damaged sections of cable lines.

  • Telephone Line Monitor

    AI-5120 - Advent Instruments Inc.

    The AI-5120 is a compact device designed for monitoring and analyzing signals present on the telephone line. By sensing the voltage present on the telephone line it detects and measures ringing, DTMF & pulse dialing, FSK (Bell 202 and V.23) signals, line polarity reversals, and open switching intervals (OSI). Working in conjunction with the TRsSim software on a PC, the AI-5120 becomes a valuable tool in analyzing and debugging Caller ID and SMS (Short Message Service) data transmission. Like an oscilloscope, it can capture and display waveforms showing various signals present on the telephone line.

Get Help