Showing results: 3976 - 3990 of 6622 items found.
-
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
Precision Analog Systems Co.
Precision Analog Systems signal conditioning output amplifiers can increase the voltage output drive to +/- 200 Volts at 12 mAmps. Our high current amplifier cards provide 24 Volt output signals with 500 mAmps of output current. PAS offers boards that provide various combinations of output voltage and output current drive capability. Please see below for our current product list.
-
98x -
Vitrek Corporation
The new 981i and 983i Teraohmmeters are designed to tackle the toughest High Resistance measurement applications. Demanding applications that most other IR testers won’t measure up to. So when it’s time to test higher voltage IR values like today’s electric vehicle systems and higher voltage solar arrays — look to Vitrek to deliver the IR tester you need for your production line.
-
ETL-35K -
Kharkovenergopribor Ltd.
ETL-35K system has a multitude of applications in electrical equipment testing and maintenance: testing cable insulation with DC (rectified) voltage up to 60 kV, measuring small leakage current of surge arrestors, high-voltage testing with AC voltage up to 100 kV at industrial frequency, underground utilities tracing, cable fault pre-location and pinpointing, and measuring capacitance and tan delta of various electrical objects at industrial frequency.
-
AUTO DIAGNOSTECH LTD
Our innovative multi-function Electrical Component Testers have advanced functions such as voltage power control feed to activate components like radiator fan, headlights, horn, actuators, etc. and the sensor simulator can provide simulation of voltage signals, frequencies, square waves & duty signals with varying intensity to test the feasibility of good sensor signals in comparison to bad ones when troubleshooting vehicle electrical faults.
-
Meco Instruments Pvt. Ltd.,
High AccuracyRange Selection & Single Person Push Button OperationLCD Back Light Function with Indicator SwitchData Holding Function, Function Icons on DisplayMeasurement of AC Voltage upto 600VACMeasurement of Phase Sequence between (Phase-PhaseVoltage)with LED Indicator Auto Range (Insulation Test)LED Indicator for High VoltageInbuilt Protection Circuit to prevent the harm of reverse voltagesBattery Operated with AC Adaptor3 Ranges of Voltage & Insulation Resistance
-
Hilo Test
Hilo-Test offers a large number of coupling / decoupling networks for single-phase and 3-phase power supply lines and signal data lines and telecommunication lines. In addition to numerous standard versions Hilo-Test also supplies special variants for higher voltages (e.g. 3x690 VAC or up to 1 KV DC) and high currents (up to 200 A or more), as well as for surge voltages up to 12.kV. TheIEC 61000-4-4/5standardsformainlyvalid.
-
72-10415. -
Tenma
*Handheld digital multimeter*Measure AC/DC voltage, AC/DC current, resistance, frequency and capacitance*Diode test and continuity buzzer*Manual function select & auto ranging*Data hold function*Auto power off, low battery indication*Input impedance for DC voltage around 10Mohm*MAX / MIN / Relative Modes*Analog Bar Graph*CAT III 1000V, CAT IV 600V rated
-
MRS-26D -
Hangzhou Huatai Optic Tech. Co., Ltd.
*Ultra low noise push-pull technology *Band width of 2.7 GHz* 46dB CNR (typ.) for NISC with OMI = 4% at –8dBm optical input power @ 1550nm* 20dBmV RF output level (-5dBm,1550nm,OMI=4%)* Very low intermodulations *Low power consumption *Small package with single-mode fiber pigtail *Integrated optical demultiplexer (WDM filer) for RF overlay applications *Monitor voltage output and output disable input
-
PDMT08 -
Pyle Audio Inc.
Double-Molded Plastic HousingHigh-Contrast LCD DisplayCATIII RatedVoltage DC: Max Range 600 V, Accuracy: +/- 0.5%Voltage AC: Max Range 600 V, Accuracy: +/- 1.2%Current DC: Max Range 10 A, Accuracy: +/- 2.5%Resistance: 2 M, Accuracy: 0.8%Diode CheckContinuity TestAccessories Included: Test Leads, 9V BatteryDimensions: 5.91' H x 2.76' W x 1.89' DWeight: 8.99 oz.Sold as : Unit
-
CFAs -
Communications & Power Industries
CPI BMD’s crossed-field amplifiers (CFAs) are broadband, phase-stable microwave amplifiers used in coherent radar chains to efficiently generate very high peak output powers from relatively low input voltages which can be either applied to the cathode or an electrode similar to a TWTs cathode or grid pulsing, and in relatively small, lightweight packages. These characteristics make CFAs particularly well-suited for applications in which the transmitter must be either airborne, transportable, mobile or portable.
-
DPS16 -
APPLICOS
The DPS16 is a dual-channel power supply with very low output noise and no ripple. The output current can be up to 200 mA and has a programmable current limit. The 4 wire capability provides an excellent load regulation. Because the DPS16 is a fully linear design the output noise is exceptionally low while there are no ripple components as usually seen with switched mode designs. The unit has voltage and current read back on both channels with 16-bit resolution.
-
McLAREN Applied Technologies
The output of the fluid level sensor is a voltage which changes in direct proportion to the level of fluid in the probe. The difference in permittivity between air and the fluid being measured changes the capacitance between the probe's two concentric tubes as the level changes. An RS232 connection to a PC allows the user to calibrate the fluid level and thermal drift compensation. The probe is factory replaceable, allowing the electronics to be re-used should the probe become damaged or if a new probe length is required.
-
GPSL09 -
INSTOCK Wireless Components, Inc
GPSL09 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while blocking the DC current path. Max voltage rating at the DC blocked ports is 10 VDC; maximum current rating is 50 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL09 weighs only 21 grams and is suitable for applications requiring low-weight parts.
-
Alliance Support Partners, Inc.
Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.