Showing results: 1246 - 1260 of 6609 items found.
-
DTS Series -
High Voltage Inc.
The DTS Series provides repeatable and accurate measurements of the breakdown voltage of insulating oils used in electrical equipment. The DTS-60D & DTS-100D offer 60 kV AC and 100 kV AC output respectively. They include three user-selectable, automatic voltage rates-of-rise, and automatic voltage shutdown with the meter indicating the flashover voltage. Various test cells are available.
-
Greenlee Tools
*Adjustable to safely detect power and low voltage*Safely detects AC voltage without touching the bare conductor*Adjustable for use on power wiring plus lighting, thermostats and other low voltage circuits*Use to detect voltage in outlets, lighting fixtures, wires and cables*Finds breaks in wires*Identifies hot and neutral conductors*Low battery indication
-
SG7601/7602 -
Shanghai Jiuzhi Electric Co., Ltd.
SG7601/SG7602 Digital Recurrent Surge Generator is the first digital and most big range recurrent surge generator, it is a low voltage equivalent, with one stage only, it has wide range of applications includes the testing of models, the study of voltage distribution in high voltage windings during impulse voltage stresses and the predetermination of the impulse circuit parameters of the test plants.
-
AD8488 -
Analog Devices Inc.
Analog Devices’ charge integrator amplifiers convert the charge acquired by X-ray or photodiode detectors to a voltage. The channels are composed of CMOS transistors, using typical high input impedance CMOS gates. The integrators generate charge dependent voltages using a range of selectable capacitance values that accommodate a broad range of input charge values. The integrators are followed by single-ended input to differential output voltage amplifiers where offset and low frequency noise voltages are subtracted from the input voltages.
-
LSP-500VAS -
Lisun Electronics Inc.
AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCUProtection for over hot, thundering voltage and currentTotal voltage distortion: ≤0.6%; Voltage stability: ≤0.1%/30minDownloadOutput voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400HzInput Power: single phase 220V and 50/60Hz (other input spec can be option)Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
R.R.Transformers & Equipments
RR Enterprises provides all type of transformersSingle Phase and Three Phase upto 100 KVA.The transformers can be→ Air Cooled→ Epoxy Cast→ Oil CooledWe provide transformers in high voltage and low voltage. These are used for various industrial and research purposes.→ High voltage transformers for corona and static elimination.→ High voltage transformers for plasma welding.→ Special purpose high voltage transformers.→ High current transformers for metalissing plants.→ Special purpose high current transformers.
-
72-7295 -
Tenma
The 72-7295 is a 40VDC Laboratory Grade Switching DC Power Supply with precision coarse and fine output voltage and current limiting controls. The output Overvoltage protection protects voltage sensitive load by instantly shutting down the supply when the output voltage goes beyond the set voltage due o line surge or otherwise. Current limiting control with automatic cross over of constant voltage and constant current modes makes this unit ideal for R&D work in laboratory situations.
-
Gardner Bender
Clamp meters test AC/DC voltage, DC voltage, resistance and continuity. Measure conductors at any point in the wire or cable.
-
B-1012-B -
ROSS ENGINEERING CORPORATION
High Voltage Probes for Very Low Current Power Supply Voltage Measurementto 120kV, such as Electrostatic Paint Spray Applications...
-
5310(0~500Vrms/1KVA) -
PRODIGIT Electronics Co, Ltd.
Voltage output has totally six ranges,maximum up to 500V,convenient for 300V above the voltage regulation test
-
-
Foresight Electronics Co., Ltd.
At present, Iead acid storage battery’s maintenance is applied for the check of Float voltage of battery at home, it has been found that Voltage is irrelevance with Capacity of battery, because Voltage is only to show battery’s basic parameters.Internationally, Resistance test is widely applied in daily battery maintenance instead of Voltage check, because Resistance is reflection to internal parameters of battery with high precision worldwide.
-
Hypres, Inc.
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
MRC ltd.
Oscilloscopes test voltage signals as waveforms, visual representations of the variation of voltage over time.There are two types of oscilloscope; analog and digital
-
KT-12 -
Ketai instrument (kunshan) Ltd.
● AC voltage 90~1000V ● Sound and light alarm when voltage is detected ● CAT IV1000V ● Self-check function, program control