Showing results: 5356 - 5370 of 6609 items found.
-
Greenlee Tools
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
AP033 -
Teledyne LeCroy
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
MI 3100 SE EurotestEASI -
Metrel d.d.
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
SmartMOD UP 6-500 Series -
EverFine-Industrial Co. Ltd.
The high performance ultra-compact fanless embedded box PC. Fanless system, aluminum alloy structure. Wide-range DC voltage input: 9V~32V. Support 6th Intel® Core™ processor, Skylake platform. 6x GbE ethernet. Multi-Display: 1x HDMI/VGA and 1x DP. 2x Mini-PCIe with SIM socket (PCIe+USB+USIM), and 1x Mini-PCIe socket (PCIe+USB).
-
IMV Corporation
A motion is sensed by a displacement detector, a current is fed to the coil to get back the pendulum mass to the original position. This current will be proportional to the acceleration, that is converted to an output voltage. The Servo type accelerometer is for the Earthquake Monitoring or measurements of micro tremor on the Civil Engineering Structures because of its higher sensitivity and stability or more accurate phase responses in the lower frequency range than those of other vibration transducers.
-
Pacific Instruments, Inc.
Series 6800 for laboratory applications is a ready-to-run, high performance measurement system. Enclosures are 3U rack mountable or can be used right on the desktop. 6800 units come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers, BNC for voltage or ICP/IEPE inputs or a 3-wire military grade connector.
-
930A -
Arbiter Systems, Inc.
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
Extech CLT600 -
Extech Instruments Corporation
The CLT600 is a reliable, easy-to-use tool for detecting electrical power cables, telecommunication cables, and wires in building applications. Featuring non-contact voltage technology, worklights, and an ergonomic design, professionals can safely and efficiently locate hidden wires and cables. Combining premium features including coded signals and sound and visual indications, the CLT600 is a complete solution for field troubleshooting, wiring diagnostics, and verification of electrical installations.
-
ficonTEC Service GmbH
An important aspect of the development and manufacture of laser diodes is the so-called laser diode characterization, or laser IV curve. By applying increasing current to the laser diode so it that emits light, the optical output is measured together with the voltage drop across the diode element. The resulting LIV curve reveals important clues about the quality of manufacture and the performance of the laser diode, enabling a pass/fail decision to be met.
-
40-635-105 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
40-635-006 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
40-635-106 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
40-635-005 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
40-635-007 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
40-635-107 -
Pickering Interfaces Ltd.
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.