Showing results: 796 - 810 of 6650 items found.
-
40-320-001 -
Pickering Interfaces Ltd.
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
40-320-101 -
Pickering Interfaces Ltd.
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
Extech PRC30 -
Extech Instruments Corporation
The PRC30 is a Multifunction Process Calibrator. This calibrator provides precision sourcing and measurements for thermocouples (eight types), current (mA), and voltage (mV and V) devices. Featuring 24 volt loop power, five user adjustable calibration presets, and temperature output in Fahrenheit, Celsius, and millivolts. Product includes test leads, alligator clips, thermocouple calibration cable, universal calibration cable, 100-240V AC universal adapter with 4 plugs, AA batteries, hard case, and user manual.
-
TLP-12010A -
High Power Pulse Instruments GmbH
- High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external pulse width extensions from 5 ns to 500 ns using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient software for system control and waveform data management- The software can control automatic probers for fast measurements of complete wafers- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Analog Devices Inc.
Analog Devices is an industry-leading provider of bipolar d/a converter solutions offering exceptional 1 ppm performance and optimized feature sets to ensure quick and easy deployment of bipolar converters across a range of end applications. With a comprehensive portfolio of bipolar DACs fabricated using proprietary iCMOS® process technology, ADI has enabled the development of high performance ICs at high voltage levels while simultaneously reducing package size and power consumption. By bringing together the many benefits of integration, ADI’s bipolar DACs reduce design time and system complexity.
-
4310 IN -
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
4305 IN -
Standard Electric Works Co., Ltd
• Protection class: IP65 (Lid closed)• 2 Lines × 16 Characters LCD• Microprocessor-controlled• Tests insulation resistance up to 1 TΩ • 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V• AC / DC Voltmeter (30~600V)• Short-circuit current up to 5mA• PI (Polarization Index) indication• DAR (Dielectric Absorption Ratio) indication• Auto-ranging on all insulation ranges• Auto-hold function to freeze reading• Overload protection• Adjustable testing duration: 1~30 minutes• Internal memory for data storage• Displays testing duration for insulation measurement • Auto-off function• 200 measurement results can be saved in memory and recalled on display
-
TLP-8010C -
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
F20AD -
FLC Electronics Inc
This unit contains two independent F20A amplifiers that share common ground reference and power supply.
-
A800D -
FLC Electronics Inc
This unit contains two independent A800 amplifiers that share common ground reference and power supply.
-
A400D -
FLC Electronics Inc
This unit contains two independent A400 amplifiers that share common ground reference and power supply.
-
F1020 -
FLC Electronics Inc
This unit contains two independent amplifiers that share common ground reference and power supply. Left channel correspond to the F10A model and right channle corresponds to the F20A model.
-
F10AD -
FLC Electronics Inc
his unit contains two independent F10A amplifiers that share common ground reference and power supply.
-
Volt101A -
MadgeTech, Inc
The Volt101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
-
Hilkar
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.