Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 5146 - 5160 of 6610 items found.

  • High Resistance Meter

    HR2 - Alpha Lab, Inc.

    The Model HR2 meter measures resistance in nine ranges from 1 ohm to 1.9999 Tera ohms (1.9999x1012 ohms), and conductance in a single range of 0.00 to 199.99 pS (pico siemens, or pico mhos), all at low voltage of < 2 volts across the sample. Basic accuracy is +/- 2% of reading +/- 1 count. For resistance higher than 1.9999 Tera ohms, the conductance range can be used to measure conductance down to 0.01 pS (100 T ohms). The meter has a conductance range because samples with simultaneously high resistance and high capacitance settle faster to their final value on conductance (usually under one second), than on resistance (several seconds), and conductance is also capable of detecting higher resistance than the resistance ranges can. Note that resistance in units of T ohms is the inverse of conductance in pS, so that the resistance can be calculated from the conductance. For example, 100 pS is 0.01 T ohm (10 G ohm), and the highest readable conductance of 199.99 pS is essentially 5 G ohms.

  • PIN Photodiode

    Appointech, Inc.

    PIN photodiode is a kind of photo detector, it can convert optical signals into electrical signals.This technology was invented in the latest of 1950's. There are three regions in this type of diode. There is a p-region an intrinsic region and an n-region. The p-region and n-region are comparatively heavily doped than the p-region and n-region of usual p-n diodes. The width of the intrinsic region should be larger than the space charge width of a normal p-n junction. The PIN photo diode operates with an applied reverse bias voltage and when the reverse bias is applied, the space charge region must cover the intrinsic region completely. Electron hole pairs are generated in the space charge region by photon absorption. The switching speed of frequency response of photo diode is inversely proportional to the life time. The switching speed can be enhanced by a small minority carrier lifetime. For the photo detector applications where the speed of response is important, the depletion region width should be made as large as possible for small minority carrier lifetime as a result the switch speed also increases.

  • PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit

    APCI-3501-8 - TEAM SOLUTIONS, INC.

    *8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated

  • Battery Capacity Testers|Discharge Testers

    IBEKO Power AB

    DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.

  • DC Power Supply

    62000P series - Chroma ATE Inc.

    Chroma's new 62000P Series of programmable DC power supplies offer many unique advantages for ATE integration and testing. These advantage include a constant power operating envelope, precision readback of output current and voltage, output trigger signals as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations.Designed for automated testing DC-DC converters and similar products, the 62000P sets a new standard for high accuracy programmable DC supplies. The 62000P Series includes 12 different models ranging from 600W to 5000W, up to 120A and up to 600V. Due to their constant power operating envelope a single instrument can provide both high voltage/low current AND low voltage/high current thereby reducing the number of supplies needed in typical ATE applications.

  • Bulk Current Monitoring Probe

    MP-50 - FRANKONIA GmbH

    The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.

  • Battery Loading Unit

    BLUe - Scope T&M Pvt, Ltd.

    BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.

  • Electrical Troubleshooting Kit

    Extech CB10-KIT - Extech Instruments Corporation

    The CB10-KIT is an Electrical Troubleshooting Kit that features three tools with 5 functions. The CB10 is an AC Circuit Breaker Finder/Receptacle Tester that locates circuit breakers and tests receptacle wiring. The CB10 allows the user to quickly locate 110 Volt to 125-Volt AC circuit breakers and fuses with audible and visual (LED lights) circuit breaker indication. The product also features a variable sensitivity adjustment to pinpoint correct circuit breaker. The second tool is the CT20, a Continuity Tester/Wire Tracer that tests continuity via bright flashing LED and loud pulsating beeper. The remote probe with LED allows a single user to trace up to three cables. The third tool in this kit is the DV20; an AC Voltage Detector/Flashlight with non-contact detection of AC voltage from 100 VAC to 600 VAC via built-in bright LED flashlight with ON/OFF button built in a rugged double molded housing.

  • Precision I/V Source

    Model 155 - Lake Shore Cryotronics, Inc.

    To reliably characterize developing semiconductor materials and devices, you need high quality current or voltage sources to excite samples. A cleaner (i.e., lower noise) excitation signal enables better measurement of the sample’s response. The MeasureReady™ Model 155 precision I/V sources are ideal for electronic material characterization and other demanding scientific applications requiring a precise, low-noise supply of current or voltage. Supplying 1 W maximum from DC to 100 kHz over a broad output range, these sources provide a solid foundation for I/V curve, Hall effect, and other fundamental measurements. With online software updates, your instrument will always have the most current capabilities. As Lake Shore introduces new options in the future, you can purchase and download them to your instrument. This allows the Model 155 to grow as your measurement needs evolve.

  • Earth Tester

    TAURUS PRECIOHM ET - Taurus Powertronics Systems

    The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.

  • Dry Arc Resistance Tester

    SCR ELEKTRONIKS

    Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to decomposition and erosion.AdvantagesThis Test ensures that your products meet high standards of quality & safety. This product is meant for all Switchgears/ insulator/ Polymer/ electro plastic manufacturers and manufacturers who use insulators in their products e.g. Wiring Accessories, Appliances, HT/LT line insulators etc.

  • IC/BGA Tester

    Focus-2005 - Kyoritsu Testsystem Co., Ltd.

    As a screening checker to detect defective devices(mainly electrostatic destruction)which are returned from fields before failure analysis process of IC/LC in the quality assurance division of semiconductor manufacture.As a screening checker to detect defective devices before acceptance inspection by IC/LSI expensive tester at semiconductor company(trading, manufacture)Short/Open checker for semiconductor sensor device.It is possible to measure two kinds of measurements which are constant voltage biased current measurement and constant current biased voltage measurement. User can set the threshold of 10 ranks. (auto measurement)Only device can be measured. It is also possible to fabricate the test fixture.Various devices can be measured by replacing the socket board.It is no need to generate complex test programs as reference values are calculated from good device.It can be expanded by adding multiplexer boards which are 128pins per one board.(MAX 2048pins)

  • Dual Mobile Comm DC Source w/ Battery Emulation

    66319B - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66319B dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a rack box) and eliminates the need for two separate power supplies.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Digital H.V. Insulation Tester(10kV)

    6310 IN - Standard Electric Works Co., Ltd

    ● 2 Lines × 16 Characters LCD● Microprocessor-controlled● Tests insulation resistance up to 20 TΩ● 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V● AC / DC Voltmeter (30~600V)● Short-circuit current up to 5mA● PI (Polarization Index) indication● DAR (Dielectric Absorption Ratio) indication● Auto-ranging on all insulation ranges● Optical USB to RS-232 data transmission● Well isolated from contact● Well protected from surges● 2 built-in optical LEDs for data transfer● Visual and audio warning of external voltage presence (≥30Vac or ≥30Vdc)● Auto-hold function to freeze reading● Overload protection● Adjustable testing duration: 1~30 minutes● Internal memory for data storage● Displays testing duration for insulation measurement● Auto-off function● 200 measurement results can be saved in memory and recalled on

Get Help