Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 5011 - 5025 of 6622 items found.

  • Power Supply 605D-II

    TOMSAD

    reliable and precise power of the output DC stabilization and digital LED displays. The output voltage is adjustable from 0 ~ 15V DC in smoothly with the knobs to control coarse and precise. Output current is regulated (limited) fluent in 0.6A ~ 2A. Securing the power supply protects it against accidental short circuits, and thus against overload and damage. In addition, the power supply has 5 fixed output voltages: 1.5 V, 3.6 V, 4.8 V, 6 V and 7.2 V, specially designed for mobile services, power systems and electronic components, etc. can be used in the design of electronic products, scientific work in laboratories, production lines and in teaching. Power can be used in the design of electronic products, scientific papers, laboratories, production lines and in teaching.

  • VLF Testing and Diagnostics System

    PHG 80 TD/PD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 80 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltage* Compact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • PXI Millivolt Thermocouple Simulator Module - 8 Channel

    41-760-004 - Pickering Interfaces Ltd.

    This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor. For improved accuracy each channel of the Low-Voltage Source carries accurate calibration data stored  on the module. The module also includes a calibration multiplexer for module test and verification purposes.

  • Inductive Sensors

    Bernstein AG

    In general, inductive proximity switches consist of four basic elements: a coil, an oscillator, a threshold switch and an output stage with short-circuit protection.The oscillator generates a high frequency, electromagnetic alternating field which is emitted from the active face of the coil.Eddy currents are induced in a metal object that enters this field. These eddy currents draw energy from both the electromagnetic field and from the oscillator which is consequently attenuated.The more energy taken the closer the metal object moves towards the active face. The threshold switch switches on the output stage at a defined attenuation value.In proximity switches with a DC voltage supply, this switch is designed as an NPN transistor which switches the connected load to the negative pole or as a PNP transistor which switches the load to the positive pole. The output stage is a thyristor or a triac in AC voltage switches.

  • Precision Capacitance and Dissipation Bridge

    SG2008 - Shanghai Jiuzhi Electric Co., Ltd.

    SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

  • ADSL / 2 / 2+ Handheld VoIP Tester

    QuickTest 500 - Vonaq Ltd

    *Rapid Testing. The QuickTest 500 ADSL2+ Tester's automatic Service Verification Test Suite starts as soon as you switch on (results are typically obtained in less than 3 minutes)*Simple to use. Virtually no product training required with QuickTest 500 ADSL Tester*Configurable Pass / Fail Indicators on the LCD display and clearly presented in multi-colour LEDs on the front panel*No need to get a laptop out*Save and name up to 16 test results at any one time*Line Voltage LED indicates poor, missing or excessive Line Voltage*ADSL/2/2+ Test LEDs to indicate if ADSL Showtime achieved*In Service LED indicates problems with PPP or IP layer*LEDs to indicate problems with the Trained Line Rate, poor Noise Margin or excessive Line Attenuation

  • Digital Insulation Multimeter Tester 1 KV

    MIRT-61 - The Motwane Manufacturing Company

    The MOTWANE multipurpose tester Model MIRT-61 is a Versatile, battery operated Digital insulation tester with true RMS industrial grade multimeter features best suited for industrial preventive maintenance. With test voltage range up to 1 KV , highest insulation resistance range of 6G Ohm and multi featured function of RMS multimeter (i.e. AC/DC 1000 V) ; makes it a superior offering for Industry and Service segment. It is designed predominantly for low voltage insulation resistance testing in maintenance and services, which involves the applications like Cables/Wires, Rotating Machines, LT transformers, Switchgears and Industrial installations. It is designed to suit the extreme environment conditions. Save your operating cost and test more with this single box design rather buying two different products.

  • PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module

    779618-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6230, 8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Hybrid, Multifunction I/O

    779616-01 - NI

    8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module

    779620-01 - NI

    16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.

  • Digital Multimeters

    ST-3501 - Standard Electric Works Co., Ltd

    ● Display: 3½ digit liquid crystal display (LCD) with max.    reading of 1999.● Polarity: Automatic, (-) negative polarity indication.● Zero Adjustment: Automatic.● Over Range Indication: Highest digit of (1) or (-1) is displayed.● Low Battery Indication: The (BAT) is displayed when   the battery voltage drops below the operating voltage.● Measurement Rate: 3 measurements per second, nominal.● Operating Temperature: 0°C to ±50°C, 0-70% RH.● Storage Temperature: -20°C to +60°C, 0-80% RH,    with battery removed.● Accuracy: Accuracy specifications at 23±5°C, less than 75% RH.● Power: Single, 006P 9 volt battery● Dimensions: 128(L)×72(W)×33(D)mm.● Weight: Approx .200g

  • 11 Function True RMS Multimeter

    Extech EX363 - Extech Instruments Corporation

    The EX363 is a Compact HVAC True RMS MultiMeter with a Built in Non Contact Voltage Detector. Featuring highly accurate True RMS measurements, LoZ for the prevention of false readings caused by ghost voltages, .5% basic accuracy, a 1000V AC/DC volt range, resistance up to 40MΩ, continuity beeper with visual alert, smart data hold, peak hold, auto power off with disable, relative mode for capacitance zero and offset adjustment. Additionally, the EX363 excels in HVAC flame rod measurements with a µA function, as well as Type K Temperature measurements from -40 to 742°F (-40 to 394°C) and Frequency and Capacitance measurements. Complete with test leads, 9V battery, holster with tilt stand, general purpose bead wire temperature probe and built-in magnet.

  • Earth Contact Resistance Testers

    Premier Electrosystems

    The Earth Contact Resistance Tester is a basic safety test prescribed in many IS standards. The goal is to test samples for the proper connection of earthing wire with the appliance. Premier's ECR tester checks the contact resistance between accessible metal parts of the appliance and the Earth pin by passing a high current and measuring the resultant voltage drop.

  • Secondary Injection Test Set

    PTE-100-C Pro - EUROSMC, S.A.

    The values which are presented in the LCD display are highly accurate, easy to read, and independent of the injection made by the PTE-100-C base unit.The display shows continuously the phase difference between the voltage and the current injected, and can be adjusted during the test with an accuracy of 0.1º. This facilitates the test for directional relays or reclosers and synchronizing relays, etc.

Get Help