Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
Input Characteristic Analyzer of Electronic Ballast
UI2001
-
• 4 display windows for V (600V), A (2A), W, PF/Hz • THD, 0 to 39th harmonic components • Accuracy: ± (0.4% reading + 0.1% range + 1 digit) • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
Product
Voltage Probe
VOL-PBE
-
• EMI Receiver equipped with voltage probe can test disturbance voltage from load terminals or control terminals
-
Product
Low-Temperature Impact Device
DWC-1
-
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
Product
Integrating Sphere Spectroradiometer System for LED
LPCE-2(LMS-8000)
-
LPCE-2(LMS-8000) is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 127-1997 and IES LM 79-08 standards, it recommends using an array spectroradiometer with integrating sphere and photometer head to test SSL products. LISUN GROUP developed LPCE-2 test system for LED products.
-
Product
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1800BCCD
-
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Pull Out Device
BCL-1
-
This Pull out device BCL-1 is designed and manufactured according to relevant standard requirements of IEC884-1/ GB2099.1-2008 and other electrical accessories standards, Mainly used to test the needed maximum force when the plug pull out from socket and the minimum force when single stage plug pull out from socket, and to inspect whether the socket can withstand the lateral stress imposed by electric plug into the socket. This device is applied to plugs and sockets which rated voltage no more than 250V and rated current no more than 16A.Specifications: • Weights: 36N*1, 5.4N*1, 5N*2, 4N*1, 2.6N*1; • Standard testing plug: each one for Dipolar 10A, tripolar 10A and 16A • Standard test bolt: Each one for 1.5N and 2N • 1 set of clamping device • 1 set of Weights tray • Lateral stress weights 5N*1 • 1 set of lateral stress bar
-
Product
Three Loop Antenna
VVLA-30M
-
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
Product
Compact Goniophotometer
LSG-1200A
-
The compact goniophotometer of LSG-1200A is used to measure the luminous intensity distribution curve, intensity data, spread angle and other parameters for Chip LED, LED Module, LED Spotlight and all other light which beam angle is no more than 180 degree. • Meets the requirements of IEC, CIE and LM-79 standards • Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4 intensity angle and 1/10 intensity angle which meets the special requirements. • Measured data is matched with international standard form (IES) and can be applied for lighting design by other lighting design software such as DiaLux • LSG-1200A has included a dark room, measures the maximum size of lamps: 180mm • Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1 • The distance between the tested lamp and detector is 316mm/1000mm • Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5° • The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90° • Test accuracy of angle: ±0.2° Work with the follow instruments as a System
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
Luminance Colorimeter
XYL-VI
-
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
Product
Electronic Ballast Tester
WT4000
-
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
Product
MOS Transistor Selector
UI9611
-
Measure parameters: Open voltage UGS (th), internal resistance RDS, Transconductance gm, Withstand voltage V (BR) DS• Test range: UGS (th) 0.1-9.9V; RDS 0.001-9.999Ω gm; 0.10-10.00s; V (BR) DS 50-650V• Test current range: 0.1A-5A adjustable, comply with different working situation• Automatic selecting, out of limit alarming, advance the work efficiency• The technique of testing RDS under the big-current, is advanced technique
-
Product
Spring Impact Hammer IK Level Tester
IK01-06
-
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Multi-Functional Selector
UI9600A
-
How to test a transistor with digital transistor selection tool? Please check the belowing Transistor’s Multi-Functional Selector measurement.
-
Product
Digital Oscilloscope
JC2202TA
-
The JC Series Digital Oscilloscope was designed and produced by high accuracy electronic components and modules. The test accuracy is world high class. It is used in all kinds of electronic products testing.