Showing results: 5821 - 5835 of 7326 items found.
-
EMM-6 -
Dayton Audio
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
Reef -
Del Mar Photonics, Inc.
The autocorrelation technique is the most common method used to determine laser pulse width characteristics on a femtosecond time scale . Del Mar Photonics autocorrelators have been specifically designed to measure the width of pulses from femtosecond lasers.
-
EASY4 / EASY4MRI -
Schmid & Partner Engineering AG
EASY4 is a complete standalone measurement system that provides high precision, multi-channel electromagnetic field and temperature evaluations.
-
Element -
Onto Innovation
The Element system is the tool of record for wafer suppliers for high speed impurity mapping and epi thickness measurement. It is the only tool on the market with the unique combination of transmission and reflection based technology. This system is the industry standard for dielectric monitoring.
-
KFM2150 System -
Kikusui Electronics Corp.
The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.
-
Spider-80SG -
Crystal instruments
The Spider-80SG is a high precision, general purpose data acquisition device featuring strain gage measurement. This device can be used in a variety of physical and measurement tests. The Spider-80SG can acquire data from a strain gage or a wide range of measurement quantities. A variety of general purpose and strain gage based sensors are supported. The Spider-80SG is built on the proven outstanding performance and reliability of Crystal Instruments’ DSP-based hardware platform. It features the same form factor as other Spider-80X front-ends from Crystal Instruments and can be configured into one measurement system with excellent compatibility and scalability. This gives the Spider-80SG capabilities to reliably acquire data from multiple sensors and for multiple measurement quantities simultaneously.
-
HMS-5500 -
ECOPIA
Variable temp : 80K ~ 350K (model# : AMP55T ) - HMS-5500 can be compatibly used with both low temp magnet kit (model# :AMP55T) and high temp magnet kit (model#: AHT55T5, upto 500dC) - Below image is to show model# HMS-5500 + AMP55T, for low temp.
-
FD-20 -
JFE Advantech Co., Ltd.
This device supports the measurement of rivers, Agricultural water, Sewage systems, Other channels and facilities.
-
MKS Instruments
The Granville-Phillips® Series 835 Vacuum Quality Monitor (VQM™) combines the highest performance gas analysis technology with intelligent functional design that transforms complex measurement into actionable information. The 835 VQM is the world's fastest, lowest power mass spectrometer with full data collection, spectral deconvolution, and data logging at 85 ms capture rates for the full 1-145 amu measurement range or 125 ms for 1-300 amu.
-
yieldWerx Semiconductor
Gauge R&R provides an analysis technique for engineers to determine the amount of variability caused by a measurement system. For semiconductor devices to ensure that specifications can be guaranteed the repeatability and reproducibility of measurements need to be small relative to the measured specification tolerances. Primarily product and test engineers use this to assess test equipment. Yet with advanced design-for-test (DFT) based test methods which rely upon on-die circuitry to take a parametric measurement, design engineers should perform a Gauge R & R analysis to understand their on-die measurement variability.
-
Gamma Scientific Inc.
Our Goniometetric measurement systems are optimized to provide precise measurement of angle dependent spatial radiation properties of LED luminaires, lamps and other light-producing modules. Using a variety of photometric and spectroradiometric detector options, our goniometer systems achieve optical properties as a function of angle with accuracy, precision and speed.
-
Maschinenbau Haldenwang GmbH & Co. KG.
When measuring exhaust gas, the CO concentration or - in diesel vehicles - the smoke gas opacity is measured. In this way it can be determined whether the exhaust system meets the legal requirements and is in perfect condition.
-
MPS2 -
Holding Informtest
The MPS2 module is a mezzanine module designed to form DC resistance in two channels with a four-wire measurement circuit. MPS2 is installed on the mezzanine carrier - the NMU module and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NMU module. The NMU module together with the mezzanines installed on it forms a VXI module of the size C-1 and is used to create information measuring VXI systems.
-
FTN01 -
Hukseflux Thermal Sensors B.V.
The FTN01 Field Thermal Needle System allows performing fast, on-site measurements of the thermal resistivity or conductivity of soils, in particular around the typical depth of burial of high voltage cables. FTN01 is designed with a focus on robustness and saving time, while still offering sufficient accuracy for typical field measurements. The sensor is a Non-Steady-State Probe (NSSP), TP09, which is mounted at the tip of the Lance LN01. The system is operated using a hand-held Control and Readout Unit CRU01.
-
Fluke Corporation
The Fluke Connect system of software and wireless tools help increase productivity, lower costs, and maximize uptime. Identify impending motor failure or chiller trouble or streamline panel studies and isolate intermittents more quickly. So easy, little to no training is needed to gather reliable measurements. See how Fluke Connect helps lower the costs of equipment ownership.