HR25K -
Mirmorax AS
The Mirmorax Oil-in-Water analyzer is based on an ultrasonic measurement technique in which individual acoustic echoes are characterized using advanced signal processing.
-
RTG100 -
Mirmorax AS
The Mirmorax Oil-in-Water analyzer is based on an ultrasonic measurement technique which is a direct measurement on individual acoustic echoes that are characterized using advanced signal processing.
-
Mirmorax AS
The Mirmorax Oil-in-Water analyzer is based on an ultrasonic measurement technique in which individual acoustic echoes are characterized using advanced signal processing.
-
EM-6104-1 | 20 MHz-18 GHz -
Electro-Metrics Corp.
The EM-6104-1 is an omni-directional, dual band, hybrid antenna covering 20 MHz-18 GHz. The antenna features wide frequency coverage making it an excellent choice for a variety of applications such as general purpose measurements as well as wideband security applications. This lightweight antenna is ideal for deployable applications that require wideband coverage in a very small footprint. The antenna’s elements collapse for convenient storage and transport. The antenna is configured to mount on a standard ¼-20 tripod stud. The EM-6104-1 Omni-Directional antenna is supplied with an EM-6089 Battery Pack.
-
AP3203 -
Delta OHM S.r.L.
Omnidirectional hotwire probe with cable for Thermal Comfort measurements. Measuring range: air speed 0.02...5 m/s, temperature 0...+80 °C.
-
OmniPower -
Acoustic Engineering
OmniPower Type 4292-L is an omnidirectional sound source, intended to be used in acoustical measurements for which a uniform spherical sound radiation is required.OmniPower complies to the ISO 3382, ISO 140 and DIN 52210 standards, and is used in both room acoustics and building acoustics applications.
-
DS3 -
NTi Audio AG
The Dodecahedron Speaker Set offers a lightweight, yet powerful signal source for room & building acoustic measurements. The optimized frequency response ensures precise measurements in accordance with the ISO 16283 and the ISO 3382 standards. The set includes the robust omnidirectional DS3 odecahedron Speaker and the remote-controlled PA3 Power Amplifier. Equalized acoustic frequency spectrum from 100 Hz to 8 kHz.
-
BAS001 -
Larson Davis, Inc.
The BAS001 Source is designed to generate omnidirectional sound fields for making standard compliant measurements including: reverberation time (ISO 3382, ASTM E2235), building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-4 ISO 140-3, ASTM E336, ASTM E90, DIN 55 210). The BAS001 is typically used to saturate a room with a uniform acoustic field. The available high-efficiency power amplifier has no fan for cooling, allowing measurements in quiet environments, like those in reverberation time applications.
-
TM1 - TM1 PLUS -
Audix Microphones
The TM1 is a 6 mm pre-polarized condenser microphone used for test and measurement applications. The TM1 is known for its linearity, accurate response, consistency, ease of use and affordability.
-
NIR-6000 Series -
Sensortech Systems, Inc.
The Sensortech NIR-6000 Series are continuous on-line near infrared (NIR) analyzers that deliver reliable non-contact moisture measurements directly in process environments for monitoring and controlling almost any production line. This series is especially suited for high-throughput industrial applications including wood, building materials, pulp and paper, and several other products where moisture content directly impacts product quality.
-
Sensorex
Sensor delivers accurate, reliable measurements of conductivity and total dissolved solids (TDS). Sensor package is built with automatic temperature compensation (ATC) with options for integration to most conductivity meters and transmitters.
-
Zhejiang ULIRvisionTechnology Co., LTD
According to different forms of use, infrared cameras can be divided into online thermal imaging cameras and portable thermal imaging cameras. Here we will discuss the usage and application of online thermal imaging camera compared to portable infrared camera.
-
ON-LINE TOC-VCSH -
Shimadzu Corp.
Combustion catalytic oxidation / NDIR method The functionality for continuous automatic measurement has bee added to the ability of the combustion catalytic oxidation/NDIR TOC-V Series to perform high-performance, high sensitivity measurement of organic substances. The On-line TOC-VCSH can be used for Continuous automatic high-sensitivity monitoring of water samples such as pure water and tap water.
-
Boxray Compact -
Xore AB
For most concentrator plants. The Boxray Compact onstream analyzer has three measurement cells that are mounted on a sled that moves sideways. Two cells are used for sample streams and the third is adapted for a reference sample. Boxray Compact is equipped with a multiplex system that allows up to 16 sample streams, eight streams to each of the two measurement cells. The reference sample is analyzed on a configurable interval.
-
Boxray 24 -
Xore AB
For many concentrator plants. The on-stream analyzer Boxray 24 consists of a carousel equipped with 24 measurement cells. This enables a single analyzer to monitor multiple sample streams and process steps, from ore to concentrate and tailings. As each stream has its own loop and measurement cell, there is no risk that samples will be contaminated by other streams, which can corrupt analysis results.