  • Hysteresis Brake Dynamometer

    MOTOMEA

    *Uses Hysteresis brake for measurement devicesIn addition to minimizing the magnetic field aperture in which the hysteresis cup rotates, this component minimizes the cup’s moment of inertia, enabling improved torque-control precision and controlling vibrations at high RPMs.*Enables stable measurements from low through high RPMsTorque is detected by the force exerted by the brake stator, enabling stable torque measurements from low through high RPM rages. This component features a maximum speed of 30,000 rpm (depending on torque rating). In addition, optional components can be used to improve speed resolution for use with low-speed motors of 100 rpm or less.*Compatible with broad range of torque ratings from 5mN*m through 50 N*mMeasurements components can be selected to suit motor power to ensure high-precision measurements. Users can select from 14 models of TA/TB torque measurement components, offering differing torque ratings.*Long-lasting non-contact brake Hysteresis brakes are non-contact devices and offer long service life. Except for bearings, hysteresis brakes have virtually no maintenance requirements.*Superior heat resistanceAnother hysteresis brake advantage is its resistance to changes in torque values due to increases in brake temperature or surrounding temperature.

  • Motor Test for Stepping Motors

    MOTOMEA

    *Stable measurement: Since it uses Prony braking, this model provides stable measurement unaffected by moments of inertia and no coupling loss. In addition, the resulting measurements allow data correlation via the traditional double-balance method.*Precision measurement method: This model’s judgment of synchronization loss achieves high stability using algorithms developed by Sugawara Laboratories. Measurement mode can be chosen based on step angle. For pull-in torque, startup can be measured consistently from the holding state. Allows measurement at 1-Hz resolution.*Broad measurement range: This model offers a range of seven available measurement heads, from 0.5 N to 50 N, allowing use for high-precision measurements. Through selection and use of pulleys, this model can also be used to measure small motors of 0.5 mN·m or less or 500 mN·m motors. Pulley diameters and other settings are easily configured using a personal computer running Windows®. Note: Any of the seven available heads may be attached to a single measurement component.*High-visibility measurement data: Motor characteristics are easily ascertained on automatically plotted performance graphs. Measurement data can be overlaid up to four times. In addition, the cursor can be used to read accurate values from measurement points. Hard copies of data displayed on-screen can be printed from a personal computer.*Can be controlled using standard personal computers: Allows control of measurement operations and display and storage of data from a standard personal computer running Windows®. Data is stored in CSV-format files for compatibility with other software applications.

  • Type K/J Single Input Thermometer

    Extech TM100 - Extech Instruments Corporation

    The Extech TM100 Type J/K Single Input Thermometer has a wide temperature range of -328 to 2501°F/-200 to 1372°C for type k and -346 to 2012°F / -210 to 1100°C for type j measurements. It has a high 0.1°/1° resolution and a large backlit LCD display with readouts in °F, °C, or Kelvin. The data hold function freezes the reading on the display and the screen displays the Max/Min/Avg. Readings capture a relative time stamp. Also, the offset key is used for zero function to make relative measurements. Auto power off with a disable feature. This thermometer comes complete with the Type K bead wire temperature probe and one 9V battery.

  • Integrating Spheres

    IP-Series - Lumetronics

    Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.

  • Digital Accelerometer

    ZET 7151 - ZETLAB Company

    The characteristics of the primary transducer are set in the device memory and measurements are performed based on those parameters. Thus, the digital sensors releases the user from setting the measuring channels and data processing. The sensors are fixed on the measurement object while the information transmission units are mounted in electric cabinets. An advantage of the ZETSENSOR units is easy installation and uninstallation as well as indication of feed and signal transmission which, in its turn, facilitates diagnostics of the system at the facility.

  • Air-to-Fuel Ratio Analyzer

    MEXA-730λ - HORIBA, Ltd.

    Previously MEXA-700λII used know-how and ingenuity gathered from HORIBA air-to-fuel ratio measurement technologies used worldwide, to provide the highest level of performance.The MEXA-730λ adopts this performance and adds original design for enhanced visibility and operation.A new sensor coefficient data memory function makes it possible to restore back-up data, providing faster start-up times and saving valuable operation time.This enhanced device will meet your multiple testing requirements covering applications from, lab analysis of air-to-fuel ratio, excess air ratio and oxygen concentration, to on-board real time measurement.

  • Light Meters

    PCE Instruments

    A light meter is a very sensitive electronic measuring device used to help monitor the illumination of any given area. Most light meter devices are small in size, simple to operate and equipped with an easy-to-read lighted screen made of special glass. Typically, a heavy-duty housing protects the light sensor inside the light meter from damage. A light meter is used for measuring brightness in lux (lx), foot candle (fc) or candela per square meter (cd/m²)measuring units. Some light meter devices are equipped with an internal memory or data logger to record and save measurements. The measurement of light intensity with a light meter is becoming increasingly important in the workplace due to safety concerns. Light measurement is also necessary to determine the best location and angle when installing and adjusting solar panels.

  • Stand Alone and Secure Data Acquisition

    LogMessage 5000 - Delphin Technology

    The LogMessage 5000 is equipped with 16 universal analog inputs. The inputs are designed to cope with high voltages between individual channels. The LogMessage 5000 therefore has no problem measuring non-isolated signals.LogMessage 5000 is an independently operating data logger for acquiring, monitoring, computing and storing measurement data. An internal data memory enables uninterrupted storage of up to 60 million measurement values.Delphin customers are especially impressed by the system's intuitive method of configuration and the many options provided by the device.

  • Surface & Volume Resistivity Meter for Nonconductive Materials

    Hiresta UX - OAI

    The new Hiresta-UX is a high performance meter for measuring the surface and volume resistivity of a wide variety of nonconductive materials. With an extended measurement range of 103 ~ 1014Ω, this meter is ideal for Production, Engineering, R&D and Quality Control. The new Hiresta-UX features powerful new algorithms that automatically choose the right voltage, which optimizes the surface and volume resistivity testing. This versatile, high performance resistivity meter includes a built-in switch box that can be mated with a J-Box (meets JIS K 6911 for surface & volume resistivity and is compatible with ASTM D 257) as an option. The Hiresta-UX can store up to 2,000 measurement results, which can be easily exported to a USB memory device.

  • type 1 ios test and measurement microphone

    iprecisionmic - AudioControl Industrial

    iPrecisionMic is the only Type 1 certified microphone that is also an iOS direct-connect Lightning accessory. iPrecisionMic is factory calibrated to +/-0.1dB using a NIST traceable pressure-compensated calibrator. The calibration offsets are store in the microphone's nonvolatile memory, and are transferred automatically to an iOS device running our AudioTools app.

  • Miniature, Battery Powered, Stand Alone Pressure and Temperature Data Logger

    PRTemp101A - MadgeTech, Inc

    The PRTemp101 is a miniature, battery powered, stand alone pressure and temperature data logger. This is an all-in-one compact, portable, easy to use device that will measure and record data for up to 8,191 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged.

  • PXI Device Power Supply - 4 Isolated Channels, 20-bit Measurement Resolution

    52310e series - Chroma ATE Inc.

    Chroma 52310e Series i s a programmabl e PXI-Express DPS (Device Power Supply) Card designed for high-accuracy and reliable output power for device test applications. Its compact size, easy level of integration, and high flexibility make the 52310e Series ideal for multi-channel power supplies. Chroma 52310e Series features 8 selectable control bandwidths to ensure high speed output and stable operation; multiple current measurement ranges with a 20-bit DAC/ADC provide the highest resolution and accuracy with a sampling rate up to 600K S/sec; programmable internal series resistance for battery simulation. Chroma 52310e DPS series has a patented hardware sequence engine that has deterministic t iming to cont rol each DPS channel. The sequencer's on-board memory can store up to 1024 sequencer commands and 32k measurement samples per channel.

  • Wind Meters

    PCE Instruments

    According to the type of application, wind meters are made as hot wire wind-meters or pocket weather wind-meters, all of these wind-meters can measure air velocity and air pressure. Wind meters for the measurement of air velocity and air pressure. The measurement results can be stored in memory of the device (depending on the model). There are a lot of different instruments available in our stores. These wind meters are ideal for taking quick or constant measurements. Wind meters for measuring air velocity and volume flow are available here. The pocket-sized wind meters are implemented as hot-wire wind meters, vane wind meters, cup wind meters or portable, waterproof wind meters depending on the particular application.

  • Lux Meters

    PCE Instruments

    Lux meters are used for measuring brightness in lux, fc or cd/m². Some lux meters are equipped with an internal memory or data logger to record and save measurements. The measurement of light intensity with a lux meter is becoming increasingly important in the workplace due to safety concerns. PCE Instruments' lux meters with data loggers are highly regarded in the industry due to the devices' cosine correction of the angle of incident light.Many lux meters include software for detailed analysis and offer different interfaces for transferring measured data to a computer.

  • 2 Channel IV Analyzer / Source Monitor Unit

    E5263A - Keysight Technologies

    Keysight E5262A and E5263A 2ch IV Analyzers are the low cost solution for current-voltage characterization. The E5262A and E5263A support two channels of SMUs (Source/Monitor Units) for voltage/current sourcing and voltage/current measurement with the best in the class current measurement performance as low as 5 pA. The Easy EXPERT group+ GUI based characterization software is furnished and available on your PC to support all the tasks required in the characterization from the measurement setup to the data analysis. Powerful integration of SMU's versatile measurement capabilities and GUI based characterization software makes the E5262A and E5263A the best solutions for characterization and evaluation of two or three terminal devices such as materials and active/passive components with uncompromised measurement reliability and efficiency.