7100 -
Bacharach, Inc.
The Neutronics 7100 Trace Oxygen Analyzer is a compact analyzer designed for trace oxygen gas measurement. This analyzer features a rapid-response mini-zirconia sensor with a measurement range of 0 to 1000 ppm oxygen. Extremely fast response, high accuracy, and no requirement for periodic calibrations make this analyzer a low-maintenance solution that delivers reliable performance for critical process control applications.
-
IBEKO Power AB
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
10A -
Eltel Industries
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
RMO TT Series -
Amperis sl
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
RMO TD Series -
Amperis sl
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
RMO TW Series -
Amperis sl
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
Novo-Haze TX -
Rhopoint Instruments
The Novo-Haze TX Transmission Hazemeter offers fast and accurate measurement of the optical quality of plastic films and other transparent materials. This instrument measures total transmission and haze according to ASTM D1003 (CIE C), the most important standard used in most QA applications.
-
Bunkoukeiki Co., Ltd
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
SICK Sensor Intelligence
Maintaining a clear sightline even when dust concentrations are highTransmittance dust measuring devices transmit light through the entire duct. With this type of measurement, light attenuation indicates the concentration of dust inside the duct. These measuring devices are specially designed for medium to high dust concentrations and large duct diameters. Consequently, they are equally suited to emission and process monitoring as they are to hall monitoring applications.
-
CFP-8000 -
Shimadzu Corp.
The CFP-8000 is pretreatment unit that is used with CGT-7100 or NOA-7100. When performing continuous gas analysis, dust and moisture must be removed from the gas before sending to the analyzer. This essential preprocessing can be performed by this one device, and two lines of cleaned measurement gas can be used simultaneously. Light-weight and compact, the CFP-8000 is the perfect preprocessor for use with portable analyzers.
-
CGT-7100 -
Shimadzu Corp.
The CGT-7100 analyzer measures the concentration of gases in a continuous way, using a ratio photometric non-dispersive infrared absorption (NDIR) method. All pretreatment parts required for measurement, such as the pump, filter, and electric dehumidifier, are built-in. The analyzer can measure three components including CO, CO2, or CH4 (any two of these) and O2, and is compatible with measurement at 100 vol%. The CGT-7100 has wireless communication capability, so measurement values and charts can be displayed on PCs or smart devices. And measurement data can be exported using a USB flash drive.
-
NOA-7100 -
Shimadzu Corp.
The NOA-7100 adopts the normal pressure chemiluminescence method is adopted for NOx measurement, and the zirconia method is adopted for O2 measurement. NOA-7100 is “All-in-one portable analyzer” that incorporates the pretreatment parts needed for measurements. Switching between eight ranges from 25 to 4,000 ppm supports a wide range of NOx measurements. The NOA-7100 has wireless communication capability, so measurement values and charts can be displayed on PCs or smart devices. And measurement data can be exported using a USB flash drive.
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
Triaxial accelerometers are intended for simultaneous measurement of vibration in 3 perpendicular axis. All models have a central drilling for easy screw attachment and convenient axis alignment.
-
SK-8301 -
Kaise Corporation
Accurate measurement by- True RMS- Built-in XYZ triaxial sensorFor 40Hz to 1kHz magnetic field measurement.uT and mG are selectable.MAX/MIN and Average measurements.Compact and easy-to-carry.Easy operation by only 3-keys.
-
DELTA
Two measuring methods are used for measurement of screening efficiency - Transfer impedance, Screening attenuation. EC (European Cabling) Group of DELTA has during the last years supplied many customers with test fixtures for measurement of transfer impedance. The use of the fixture has now been extended to comprise screening attenuation measurement according to the triaxial method.