Showing results: 4786 - 4800 of 7335 items found.
-
NUL-238 -
Neulog
The NeuLog calcium sensor enables measurements of ionic calcium (Ca2+) concentration in aqueous samples. This measurement is very important when evaluating water quality. It can also be used to determine calcium magnesium by EDTA titration.
-
Trimos sa
Analyze surfaces texture with nanometer precision is already a technological challenge, but TR Scan Premium is able to perform this task with unprecedented speed! The TR Scan Premium is used in workshops and laboratories worldwide. It is completely designed and manufactured in Switzerland by TRIMOS. The TR Scan is focusing on Digital Holographic Imaging Technology. Accuracy, speed, ease of use and modular construction make it ideal for all types of surface measurements.
-
A-LINE -
Trimos sa
Trimos A-line portable articulated measuring arms allow an extremely easy and accurate 3D measurement.
-
-
-
DL-HCM-Acc-Kit -
Teledyne LeCroy
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Teledyne LeCroy
High voltage differential probes provide high CMRR over a broad frequency range (up to 400 MHz) to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
-
Alpha Omega Electromagnetics, L.L.C.
At Alpha Omega Electromagnetics, we have over 20 years of world class expertise in the test and measurement of active and passive antennas as well as associated active and passive RF components. We extensively test and characterize our antennas and related RF components to ensure they meet and exceed required performance parameters as well as our customer expectations.
-
CKT1175-15 -
CK Technologies, Inc.
12.5 mV – 2000 VDCIR measurements to 5000 megohmsHipot testingDwell time prog. from 1 ms to 1000s in 1 ms steps
-
B-1015 -
ROSS ENGINEERING CORPORATION
*Spark gaps are enclosed in dust tight transparent enclosures with replaceable non-melting carbon spheres, up to 88kV PK.*Above 88kV, open style with hollow aluminum spheres is standard.*Applications for these units include over-voltage limiting, voltage measurement, capacitor discharge, and pulse forming.*Horizontal unit housings are removable.*Vertical unit housings are not removable.*Micrometer Vernier adjustment is standard for maximum accuracy on most models. Economy units without micrometer Vernier adjustment are available as an option.*Insulation to ground is available at standard and optional levels.*Spark gaps to 370kV, with motor operation available.
-
DL02-HCM -
Teledyne LeCroy
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
DL-HCM-HiTemp -
Teledyne LeCroy
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
DL05-HCM -
Teledyne LeCroy
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
DL10-HCM -
Teledyne LeCroy
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
Teledyne LeCroy
The 60 V Common Mode Differential Probes are the ideal probes for lower voltage GaN power conversion measurement with the highest accuracy, best CMRR, and lowest noise.