  • DC Bias Injector

    J2130A - PICOTEST Corp.

    When using the network analyzer to measure impedance, such as the capacitance and ESR or a capacitor, or the DCR of an inductor, etc., it is often necessary to provide a voltage bias to the device being tested. This is true of semiconductor junction capacitances, varactors, and some ceramic capacitors (especially X5R). In these cases the impedance is a function of the DC bias on the device. The Picotest DC bias injector (J2130A) is used for this purpose during impedance measurements.

  • (DCC) Resistance Bridges

    Guildline Instruments Ltd

    Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.

  • DC Current Bias Supply

    DC1000A - Voltech

    To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.

  • DC Electronic Load

    M9822/M9822B - Lisun Electronics Inc.

    M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the minor change of voltage and current, so the instrument has a wider application field and achieves better test results. Meanwhile your operation becomes much more comfortable and easy by equipping the high-light VFD, the simple menu and displayed contents and the operation state indicators on all keys. Otherwise the complete and humanized test functions will greatly improve your productivity.

  • DC Hysteresis Graph

    DX-2012SD - Dexing Magnet Tech. Co., Ltd

    Automatic measurement on basic magnetization curve and magnetic hysteresis loop under static state of soft magnetic material, accurate measurement on static magnetic characteristic parameters such as initial permeability µi, maximum permeability µm, saturation magnetic induction Bs, remanence Br, coercive Hc and hysteresis losses Pu.

  • DC Measurements

    Daqarta

    Standard Windows sound cards do not respond to DC or frequencies lower than a few Hz. (See Why Sound Cards Block DC Signals below for explanation.)There are two general approaches to get true DC response from a standard sound card: Modify the card, or add an external circuit to convert the DC into an AC signal which can be easily measured by an unmodified card.

  • DC Power Supply

    PW-3063R - PINTEK Electronics

    *Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-3063R as high as 0.1v and 0.01A.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.

  • DC Power Supply

    ◎PW-4063R - PINTEK Electronics

    *Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.

  • DC-Resistance Meter

    HopeTech

    High-stability internal resistance of the battery Meter.The main battery internal resistance and battery voltage. This product can simultaneously measure the resistance and voltage and to compare battery internal resistance and open-circuit voltage.The CHT3560 standard RS232C and HANDLER interface automated measurement fast and accurate judgment the battery deterioration of the situation, sorting products suitable for battery assembly line and factory inspection. Low resistance characteristics can be used to characterize the mechanical and electrical components down low current test conditions.

  • DC Resistance or Conductance of Insulating Materials

    ASTM D257 - National Technical Systems

    These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.

  • DC Stable Electrostatic Voltmeter

    Model 370TR - TREK, INC.

    The Trek Model 370TR is a precision electrostatic voltmeter with the unique capability of making noncontacting surface voltage measurements in the range of 0 to ±3 kV DC or peak AC.

  • DC Stable Electrostatic Voltmeter

    Model 370 - TREK, INC.

    The Trek Model 370 is a precision electrostatic voltmeter with the unique capability of making noncontacting surface voltage measurements in the range of 0 to ±3 kV DC or peak AC. 

  • Decade Resistor

    esi / Tegam DB62 - IET Labs

    IET has improved the specifications on esi/Tegam's DB62 decade resistor. These Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy of 0.01%, stability, and low zero resistance are important

  • Decade Resistor

    1433 Series - IET Labs

    The 1433 Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy, stability, and low zero resistance are important. They are convenient resistance standards for checking the accuracy of resistance-measuring devices and are used as components in dc and audio-frequency applications.

  • Decelerometer

    Maschinenbau Haldenwang GmbH & Co. KG.

    National type approval by the PTBPrinter with keyboard and digital displayFast matrix printer with graphic expressionPiezoelectric decelerometersControl and measurement electronicsElectrical equipment adjustment by means of digital displayGyro sensor for automatic compensation of the measurement error by the pitch behavior of the vehicleJacks for pedal force, pressure u. Load indicatorRS-232 interface to PC with data transfer for standard table SoftwareChargerSpare roll of paper approximately 15 mplastic suitcase