Eltel Industries
Market leaders in India for the manufacture and development of test instruments for electrical power industries and utilities.
- 91 80 22255467
- 91 80 22252733
- marketing@eltelindustries.com
- 311 Embassy Centre
Crescent Road
Bangalore, 560 001
India
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Automatic Instrument Transformer Test Set
-
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
Product
ANSI Potential Transformer Burdens
-
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
Product
Manual Dielectric Constant, Tan Delta & Resistivity Test Set
-
*AC and DC test Voltages switched internally.*Direct digital display of test voltages.*Auto ranging and direct read out of volume resistivity.*Cell constant adjustment and Tan Delta zero correction.*Built-in protection for test sample flash over.
-
Product
Standard CT
800A
-
• High accuracy of 800/5A (0.05%) • multiple ratios • Various Current ratings
-
Product
Automatic Capacitance and Tan Delta Bridge
-
*Automatic Microprocessor controlled Guarded Bridge Circuit.*Suitable for testing at voltages up to 500kV.*Can be used to measure both Grounded and Un-Grounded Specimens.*Automatic guard circuit for three-terminal measurement.*Interface measurement and automatic interference suppression circuitry.*Optional range Extension Transformer for large capacitance values.*Test data storage facility.*RS-232 computer interface and USB printer interface.*Window Interface Software for data transfer.
-
Product
Electronic Potential Divider
-
• Provides many ratios over a wide range • Small ratio and phase errors • Models operating at different voltages are available
-
Product
Standard Capacitor
-
• 3 terminal design • SF-6 Gas filled • 15kV, 33kV & 50kV models available
-
Product
Compensating Reactor
-
The compensating reactors are accessories for the CTS-12KSA/ACTS-12K Capacitance & Tan Delta Test Set. The use of one or more compensating reactors increases the capacitance that the internal power supply can excite to conduct measurements. As the measuring range of the CTS-12KSA / ACTS 12K exceeds the kVA rating of the internal power supply, one way of using the test set over its entire measuring range is to form a resonant circuit with the test sample. The use of one or more compensating reactors forms partial resonating circuit with the test specimen, thereby reducing the power supply requirement.
-
Product
Range Extension Transformer
-
• Range extension transformer to extend the capacitance range upto 2.6 micro Farad (ACTS-12K) and 2.4 micro Farad (CTS-12KSA)
-
Product
High Voltage Capacitance & Tan Delta Test Set
-
*Aesthetically designed Single Unit consisting of Measuring Bridge, Power Supply with in-built Standard Capacitor. Ideal for field /portable applications.*Highly compact & Portable – Approx 66Kgs only.*Advanced Protection Circuitry –specially suitable for 400kV s/s applications.*Successfully passed all required EMI/EMC Tests at SAMEER Chennai IEC 61000-4-2;IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-11;*Improved Plug-in type of “Power In” and “Gnd” connectors.*Preo 2 Stage RF Power line Filters incorporated for 230V Power Input and Bridge Power Input for improved EMI Power line Protection*Improved 2 sets of LV measuring cables.*Improved HV cable outer covering hosepipe for rugged field use.
-
Product
ANSI Metering Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Product
Digital Micro Ohmmeter
-
*For fast and accurate measurements of low resistance on Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds.*100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A*4 1/2 digit display for higher resolution*Wide resistance range of 20µΩ to 200mΩ in 5 ranges*Suitable for operation in energized switchyard conditions*SMPS based- lightweight and portable