  • Vehicle-Mounted Testing Transformer

    GTU-320KVA/320KV - Wuhan Sangao Electrical Test Installations Limit Co.

    GTU high-voltage testing transformer uses SF6 as the insulating gas to separate the vacuum room from the outside,this equipment reflects the smallness in size, lighter in weight,higher voltage grade for unit,convenience in transportation and operation,It can let the large capacity and high voltage power frequency transformer arrived at the scene for the high-voltage test.

  • High Current Transformers

    Hilkar

    High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.

  • Distribution Transformer Tester

    ADOC-3 - Amperis sl

    The ADOC-3 is an equipment that has been designed to test distribution network transformers from 5 kVA to 3MVA.

  • Distribution Transformer Tester

    NDB-DOC-3™ - ndb Technologies Inc.

    The NDB-DOC-3™ is a test instrument designed for distribution networks transformers from 5kVA to 3MVA. It can determine the presence of short circuits or open circuits in the distribution transformer primary winding & also short circuits on the secondary winding.The NDB-DOC-3™ is designed to be operated without disconnecting the transformer’s secondary windings from their loads.

  • Transformer Insulation Testing

    Megger Group Ltd.

    The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).

  • Automatic Transformer Tester

    SS3250 / SS3252 / SS3302 - Sanshine Electronis Co., Ltd.

    Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.

  • Transformer Capacity Tester

    Weshine Electric Manufacturing Co., Ltd

    In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.

  • Phase Shifting Transformer

    Supreme Instrument Laboratories

    Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.

  • Distribution Transformer Tester

    NDB-DOC™ - ndb Technologies Inc.

    The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.

  • Distribution Transformer Tester

    DOC-2000™ - ndb Technologies Inc.

    The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.

  • Auxiliary Potential Transformers

    Osborne Transformer Corp.

    Osborne Auxiliary Potential Transformers (Aux PT’s) are used in utility and commercial industrial power systems. Osborne works with our clients to identify the safety advantages of using auxiliary potential transformers (Aux PT’s) to establish protection schemes for high voltage equipment. Aux PT’s step the voltage down to safer levels, normally below 600 V AC.

  • Range Extension Transformer

    Eltel Industries

    • Range extension transformer to extend the capacitance range upto 2.6 micro Farad (ACTS-12K) and 2.4 micro Farad (CTS-12KSA)

  • Transformer Vibration Checker

    TC-55 - ECG KOKUSAI Co., Ltd.

    The TC-55, with its small and highly sensitive sensor, is designed to detect vibration and rumbling noise of the transformer and various types of coil.

  • Transformer Test Equipment

    IBEKO Power AB

    DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.

  • High Frequency Transformers

    Osborne Transformer Corp.

    Osborne High Frequency Transformers are isolation transformers and auto-transformers that operate at frequencies higher than 50/60 Hertz. Osborne recommends high frequency operation for certain applications that demand a significant reduction of the physical size of electromagnetic components. Osborne helps our clients take advantage of higher frequency designs by identifying and accommodating (or preventing) high frequency loss characteristics, such as skin-effect losses, proximity effect losses and stray losses.