Showing results: 451 - 465 of 1019 items found.
-
NeonPro
Design for finding out the total voltage of neon tubes in a circuit, help to Choose correct rating of neon transformer;- Easy to use just like a neon transformer;- With color LED indicators, clearly shows the test result;- With build-in over voltage protection circuit.
-
YD-Series -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication
-
NEO TELE-TRONIX PVT. LTD
Widely used for testing transformer and switchgear, this equipment is available to clients in different capacities.
-
NEO TELE-TRONIX PVT. LTD
Widely used in electrical, power generation and engineering sector, it is used for transformer testing.
-
TEGAM Inc.
Ratio Standards by Tegam including ratio transformers, synchro-resolver bridge, synchro-resolver standard
-
STCS -
Altanova Group
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
Computer Conversions Corporation
The input is transformer isolated and accuracy applies over the operating temperature range and with +/-10% input amplitude and frequency variations. The operational amplifier outputs are not transformer isolated, and can be driven into external power amplifiers and Scott "T" transformers for 3 wire synchro outputs. A typical application of this series is in a conventional positioning servo system as a complex error processor. The use of the solid state CDX makes possible the design of servo systems that can be digitally programmed by direct computer input to the digital input of the SCDX.
-
T 3000 -
Altanova Group
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
MCH Instruments Co.,Ltd.
*coil testing for motor and transformer *judge quality by comparing wave difference *LCD display
-
Carl E. Holmes Company
Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.
-
Carl E. Holmes Company
Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.
-
Shanghai Himalayal Co.
Testing object: S current transformer, normal current transformer, voltage transformer● Testing item: ratio error, phase error, impedance, admittance of the transformer, etc● Rated current:5A,1A ( Customized )● Rated voltage: 100V, 100/√3V, 100/3V, 110V, 110/√3V, 110/3V, 120V, 120/√3V, 120/3V, 220V (or other)● Measurement range: ratio error measurement range : 0.0001%-19.99% phase error measurement range : 0.01 ' -900 '● Error minimum resolution:ratio error:0.0001%; phase error:0.01 ' ● Communication function : provide RS232 serial communication port● Measurement accuracy: ±1%● Consumed power: less than 20VA● Dimension :460×380×160 mm● Weight: 12kg
-
6450 -
The Eastern Specialty Company
The TESCO CT/PT Bus-Bar Safety Protector (Catalog No. 6450) has been developed to assist in the safe disconnect of a hot sequenced current transformer. After service is disconnected, the TESCO CT/PT Bus-Bar Safety Protector is slid over the bus-bar of the load side of the transformer and prevents accidental connection and/or arcing.
-
-