Showing results: 766 - 780 of 1014 items found.
-
PI-2500 -
ETI Precision
The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.
-
AQUILA -
Altanova Group
A compact and portable Partial Discharge acquisition unit, which allows to detect and analyze partial discharge activities in all electrical assets: from power cables to transformers, rotating machines and switchgears, together with the right combination of sensors and accessories. AQUILA comes with a full range of options, ideal for field testing.
-
SS71XX series -
Sanshine Electronis Co., Ltd.
High voltage withstand and insulation tester (HI-POT tester) is used for testing insulation grade and withstanding voltage capability of electrical equipment, transformers, motor, relays, cables, electronic components, electronic applications, inductors, ignition coils, insulation wires, insulation tapes, valve coils, reactors, contactors, etc.
-
Mess- & Prüfsysteme GmbH
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
T 2000 -
Altanova Group
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
MASTER -
Lifasa - International Capacitors, SA
It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.
-
PCT200i -
Scope T&M Pvt, Ltd.
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
CX-M01 -
Shenzhen Chuangxin Instruments Co., Ltd.
IEC61588 and IEC60065 Mandrel Test Apparatus is designed and manufactured in accordance with the standard requirements of IEC61558 and IEC60065. The IEC61588 and IEC60065 Mandrel Test Apparatus is used for the insulating thin layer of the power transformer and supply unit as well as the similar products to do the spindle test, mechanical strength test and abrasion test.
-
TURNS-TTPT -
Vasavi Electronics
Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns
-
HDLT -
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
1106 IM -
Standard Electric Works Co., Ltd
● Large LCD : 68 × 34mm (2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.
-
1107 IM -
Standard Electric Works Co., Ltd
● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.
-
1826 NA -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
doblePRIME PD-Guard -
Doble Engineering
The doblePRIME PD-Guard continuously monitors partial discharge (PD) in equipment such as transformers, rotating machines, cables and switchgear.The doblePRIME PD-Guard provides local alarms and will communicate data and notifications across standard interface channels and through to networked supervisory systems. It analyzes RF emissions in the HF, VHF and lower UHF ranges.
-
R.R.Transformers & Equipments
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.