PWR1-3B -
Schuetz Messtechnik GmbH
The RATIOMETER PWR1-3B is constructed to measure the transformation ratio, phase error and magnetizing current of power- and distribution- transformers for all three-phases simultaneously. Voltage and current transformers are single phase, power transformers normally three-phase. Due to the bad quality on industrial lines (phase jitter and shifting, voltage differences between the three phases) all measurements normally are done single phase, even on three phase ratiometers.
-
Technology Products
Condition Monitoring by TP - generator, turbine, and transformer condition monitoring
-
Educated Design & Development, Inc.
As a general purpose dual-voltage isolation transformer for step-up (120 to 240 VAC), step-down (240 to 120 VAC), or straight 1:1 isolation (120 to 120 VAC or 240 to 240 VAC). Models with a suffix "UC" are provided with a safety jack for access to the transformer secondary center tap (connected to the transformer center tap only in the 240 VAC output setting). This connection may be used in conjunction with a Dielectric Voltage Withstand test.
-
doblePRIME DOMINO -
Doble Engineering
The doblePRIME DOMINO provides real time data for moisture in oil, giving indications of relative saturation or absolute ppm levels. This is useful information, especially when a transformer is being loaded in excess of nameplate or when the transformer is undergoing abnormal load cycles.
-
TYPE JF -
Shanghai Jiuzhi Electric Co., Ltd.
TYPE JF Partial Discharge Shielding Room (Factory Building) is suitable for the partial discharge experiment and impact test in different voltage band (110KV, 220KV, 500KV, 750KV,1000KV) of cable, voltage transformer, transformer, switch, and power station etc.
-
-
IEC Burden Sets -
The Eastern Specialty Company
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
-
PCT200i -
Ponovo Power Co., Ltd.
PCT200 series CT test set (CT Analyzer) is a current transformer test equipment specially designed for current transformer characteristic test and with additional PT test functions for reference test. PCT200i owns more test items and higher technical parameters.
-
921A -
Arbiter Systems, Inc.
The Arbiter Systems®, Inc. Model 921A Combustible Gas Meter is a rugged, portable instrument that measures total combustible gases (TCG) in oil-filled transformer nitrogen gas blankets. TCG measurements have been shown to be good indicators of transformer health.
-
600V Class -
AYA-Instruments
These transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. They are designed for line-to-line operation but may also be used in line-to-neutral or line-to-ground configuration at 58% of rated voltage. It is recommended that a 1.6 Amp fuse be used in the secondary to protect the transformer.
-
-
-