Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 871 - 885 of 1014 items found.

  • MIL-STD-1553 Test & Simulation Interface for PCI Express

    PCIe-C1553 - Avionics Interface Technologies

    Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Real-Time recording and physical bus replay - x1 Lane PCI Express Host Interface (x4 Physical edge connector) - Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • 904 Benchtop Six Phase 30A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.

  • Automatic Capacitance and Tan Delta Bridge

    Eltel Industries

    *Automatic Microprocessor controlled Guarded Bridge Circuit.*Suitable for testing at voltages up to 500kV.*Can be used to measure both Grounded and Un-Grounded Specimens.*Automatic guard circuit for three-terminal measurement.*Interface measurement and automatic interference suppression circuitry.*Optional range Extension Transformer for large capacitance values.*Test data storage facility.*RS-232 computer interface and USB printer interface.*Window Interface Software for data transfer.

  • Wireless Energy Datalogger

    ELITEpro XC™ Energy Logger - DENT Instruments

    The ELITEpro XC is a complete solution for pinpointing electric usage and recording building performance metrics. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers, or flexible RoCoils (for large loads or large cables and bussbars) to monitor current on each phase.

  • IP67 waterproof outdoor Split core ct

    LZCK-55 200/5A 0.5S - Beijing GFUVE Electronics Co.,Ltd.

    Outdoor waterproof Split Core CTs. Waterproof outdoor split core current transformer 55mm. Outdoor Split-core CTs are designed to meet the growing demand for outdoor installation. The working temperature and humidity is high. Parameters will be measured and compared without power supply cut-off on account of the split core, so it's popular in the energy management system and power factor correction. It can be used along with many kinds of instruments and devices.

  • LCR Meter

    SS10X Series - Sanshine Electronis Co., Ltd.

    LCR Meters are basic passive component testing equipment, can be used in quality management department or production process for quality inspection. Like as: transformer, inductor, resistor, capacitor, relay, motor, generator, electric valve, contactor, cable, wire, etc. This series LCR meter, offering different kind of testing fixtures, can improve testing precision and reduce the difference value of error code, being an economical and useful basic testing instrument.

  • Turns Ratio Meter 3 Phase

    TR-MARK III 250V - Raytech AG

    The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.

  • AC Hysteresis Graph Test System

    DX-2012M - Dexing Magnet Tech. Co., Ltd

    Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

  • Hybrid Wound Component EST Scanner

    19035 - Chroma Systems Solutions, Inc.

    The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.

  • L.V.D.T Products

    Columbia Research Laboratories

    Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.

  • Insulation Tester, Analogue / Digital Megohmmeter, 50V, 100V, 250V, 500V, 1kV, 0.01ohm to 20Gohm

    72-3105 - Tenma

    Insulation Resistance Tester Full function DMM includes AC and DC voltage measurement, plus a wide range of resistance scales designed specifically for insulation resistance measurement. It is ideal for safety and preventative maintenance work on powered tools, motors, transformers and similar devices. Large backlit 6000 count display provides at-a-glance readings via both 3-3/4 digit readout and 45 segment analog bargraph.

  • Turns Ratio Meter

    Model TRM200 - Gopal Electronics

    Turns Ratio Meter Model TRM200 is widely used in transformer industry in manufacturing and repairing service. It directly display the ratio of LT turns & HT turns. It is capable to measure turns ratio till 1:1200. Turns ratio meter is designed to be a rugged and reliable. It is equipped with stable 250mA source. The design is based upon in-house invented & patented technology. TRM200 has also option for 1amp current source on demand.

  • Digital Insulation Testers

    The Motwane Manufacturing Company

    Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.

  • Primary Test Equipment

    LET-1000-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

  • Primary Test Equipment

    LET-400-RD - EUROSMC, S.A.

    It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.

Get Help