Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 856 - 870 of 1015 items found.

  • CT/VT Test System

    Eltel Industries

    Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.

  • Primary Current Injection Testers

    Hilkar

    Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.

  • Test Automation Solution

    CONFORMIQ TRANSFORMER - Conformiq Inc

    Conformiq Transformer shortens the path to test automation, simplifies model-based testing (MBT) adoption using existing methods, and automates manual test execution. Along with Conformiq Creator, which generates executable test cases, scripts and documentation from models, it automates and transforms test design, extending the Conformiq 360° Test Automation™ solution for complex system testing at the speed of development.

  • EMF Measurements/EM Measurements/Electromagnetic Radiation

    Holland Shielding Systems B.V.

    Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.

  • MIL-STD-1553 Test & Simulation Interface for PCI

    PCI-C1553 - Avionics Interface Technologies

    Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Real-Time recording and physical bus replay - PCI & PCIx Compatible, 3.3V and 5V OperationApplication interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Aging and Life Test Rack

    SY2036 - Lisun Electronics Inc.

    SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)

  • Analysis via Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS)

    National Technical Systems

    The use of Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS) in the analysis of failure related issues of printed circuit boards (PCBs), assemblies (PCAs), and electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) is a well-established and accepted protocol. As opposed to or simply in addition to normal optical microscopy, SEM/EDS allows for the “inspection” of areas of interest in a much more informative way.

  • µModule Isolated Transceivers

    Analog Devices Inc.

    Analog Devices µModule (micromodule) isolated transceivers provide robust galvanic isolation for digital serial communication interfaces, including SPI, I2C, RS-485/RS-422, RS-232, and USB. Isolation barriers are implemented using Ethernet transformers, coupling capacitors, or embedded inductors. All devices are simple to configure, have very low EMI susceptibility and emissions, and feature high noise immunity to preserve signal integrity.

  • UHF PD Detector

    Megger Group Ltd.

    Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.

  • Rogowski Coil

    Ferrites India

    Rogowski Coils are mainly used to measure high current through the conductor. As opposed to conventional current transformers, Rogowski Coils are liner over wide range of current input. Rogowski Coils along with current meter are suitable for measurement of AC or DC current, up to a few thousand amperes. Ferrites India offers Flexible as well as hard Rogowski Coil which can accomodate wide conductor sizes.

  • MOTORIZED TRANSFORMER/RECTIFIER ASSEMBLY, 0-250 VDC, 200 A OUTPUT

    18534PS1 - Carl E. Holmes Company

    Input power is 380 VAC, 3 PH, 50 Hz, P/N 18534PS1Output is 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDCIndoor enclosure, 50"H x 46"W x 36"DOutput voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure

  • Time Interval Meter

    NEO TELE-TRONIX PVT. LTD

    Highly experienced in this industry, we are a well recognized manufacturer and exporter of Time Interval Meter. Supplied to electrical, power and engineering industry for instrument transformer and switchgear testing, this instrument is available to clients in different technical specifications. We use certified quality raw materials and components, procured from trusted vendor in market. We offer this Time Interval Meter (1 & 3 Channel) to clients at competitive price.

  • Electronics & Power

    Excelitas Technologies Corp.

    Excelitas Technologies offers a wide range of high-performance electronics, power and energetics technologies to drive your most demanding photonic systems. Our Electronics & Power offering includes Capacitor Chargers, Spark Gaps and Transformers, High-Voltage DC Power Supplies and Atomic Frequency Standards. Our Energetics portfolio includes Electronic Safe & Arm devices, Detonators, Ignition Safety devices, and Rocket Motor Initiators.

  • PCI Module

    PCI-1553-DDC-1,2 - ALPHI Technology Corporation

    The PCI-1553-DDC uses Data Device Corporation’s ACE, DDC enhanced mini BU61865G4-290 communication device as its 1553 bus controller, or remote terminal, or monitor terminal. A single controller has two redundant channels. This controller has 64Kx17 word of internal memory and internal transceivers for both channel A and B. The 3U PCI board has on-board transformers. This board has a PCI compliant interface

  • Audio Impedance Testers

    2706 IM - Standard Electric Works Co., Ltd

    ● True measurement of speaker systems actual impedance at 1kHz.● Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operated.● Low battery indication.● Data hold function.● Timer function for continuous hands free operation.● The timer can last about 3-5 minutes when users press.● TEST ON/OFF button.

Get Help