Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 946 - 960 of 1014 items found.

  • Megohmmeter Insulation Tester

    AMIC-30 - Amperis sl

    The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.

  • 20Hz Generator

    Signals & Systems India Private Limited

    In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.

  • Shielding Solutions

    Aaronia AG

    The highly transparent EMC shielding material Aaronia-Shield® and the high-tech EMC shielding fleece Aaronia X-Dream®, for example, offer very high EMC protection and are especially well equipped for all future high-frequency radiation sources in the high GHz range, which you can easily verify with our EMC Handheld Spectrum Analyzer. For magnetic field shielding, our MagnoShield® series offers unparalleled protection against alternating magnetic fields, such as cables, power distributors, high-voltage lines or transformers and generators.

  • Static Frequency Converter Systems with Built-in Isolation System

    FC3X Series - Aplab Limited

    - VFI independent output as per IEC62040- User friendly controls and indications- Compact design with inbuilt transformer- Rugged and field proven for Industrial and Defence application- Ultra light weight- Higher efficiency of operation means significantly lower running costs- State of the art IGBT based PWM technology, to increase crest factor tolerance & dynamic stability- Continuously delivers full output power at ambient as high as 45ºC- Can feed upto 400% rated current for half cycle- Very high MTBF

  • Precision LCR Meter (20Hz to 1MHz)

    ST2827 - Saluki Technology Inc.

    ST2827 series precision LCR meter has multiple functions and higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. ST2827 series is easy to operate with a 4.3-inch LCD screen as well as English operation interfaces. Integrated transformer test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • UNI-T Series

    Weshine Electric Manufacturing Co., Ltd

    mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.

  • SAE AS5643 Mil-FireWire PXI Express Test & Simulation Instrument

    HSSUB-6120 - Avionics Interface Technologies

    Highest density capability available in an AS5643 3U PXI Express, single slot instrument - Four (4) FireWire nodes, each with three (3) ports - Apps provide high-level (AS5643) and low-level (1394) access, while accommodating end-user customization - S100, S200, S400, S800 transfer rates - Support all Nodes operating concurrently at 800 Mbps - Independent transformer coupling for each port - Eight (8) standard PXI backplane triggers - Industry standard Texas Instruments IEEE 1394b Chipset - ANSI C (typical), C++/C#/LabVIEW

  • Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT

    PDMonitor - Power Monitoring and Diagnostic Technology Ltd.

    The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.

  • Insulation Measuring Instruments

    METRISO Series - GMC-I Messtechnik GmbH

    1) Voltage-free devices and equipment, for rugged service applications and laboratory use2) Voltage-free devices and equipment, and for testing resistance at earthing, protective and equipotential bonding conductors3) Voltage-free electrical devices and equipment, for testing resistance at earthing, protective and equipotential bonding conductors, and for testing devices under test for absence of voltage. - METRISO C only: testing floor coverings for discharge capability and electrostatic charging4) Electrical systems, machines, transformers, cables and equipment used in, for example, locomotives, street cars and ocean going vessels5) Electrical motors, machines, generators and cables

  • TimerBlox

    Analog Devices Inc.

    Analog Devices TimerBlox parts are small, accurate, and simple timing devices designed for six basic operations: voltage controlled oscillation (VCO), low frequency clocking, pulse-width modulation (PWM), one-shot generation and signal delay, and power-on reset (POR). TimerBlox devices combine an accurate programmable oscillator with precision circuitry and logic. No capacitors, no crystals, no microcontroller, and no programming are required. A 20 mA source and sink capability enables the devices to directly drive opto-isolators and transformers for electrical isolation. An ideal solution for space-limited applications, each TimerBlox device can be placed at the point of use.

  • Precision LCR Meter

    TH2827C - Changzhou Tonghui Electronic Co., Ltd.

    TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function  greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage.

  • 1 A DIGITAL MILIOHMMETER

    MO-2Ke - MEGABRAS srl

    The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.

  • Variable Frequency AC Resonant Test System

    HDXZ-162kVA/54kV - HD Power Test Equipment Co.ltd

    HDXZ-162kVA/54kV Variable Frequency AC Resonant Test System is applied for AC dielectric withstand test for electric equipment.The system is mainly composed of following parts:variable frequency control power supply,exciting transformer,reactor and capacitive divider.1. 10kV/300mm2 cable 3km AC withstand voltage test, capacitance ≤1.1265uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.2. 35kV/300mm2 cable 1.5km AC withstand voltage test, capacitance ≤0.2917uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • TE-Metrology

    HIGHVOLT Prüftechnik Dresden GmbH

    The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components

Get Help