Showing results: 196 - 210 of 1014 items found.
-
MLS 7100 -
Schuetz Messtechnik GmbH
The MLS 7100 transformer loss measuring bridge was especially designed to greatly simplify the determination of transformer core and copper losses – an ideal choice when working on site. The measuring bridge features open circuit as well as short circuit measuring. Many transformers can be directly connected to the MLS 7100 without needing further transducers.
-
ZERA GmbH
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
DTTS Series -
Shanghai Jiuzhi Electric Co., Ltd.
The DTTS Series Distribution and Traction Transformer Test System are self-contained test sets incorporating all features necessary for testing single and three phase distribution transformer at factory and onsite.
-
WABC -
Wuhan Sangao Electrical Test Installations Limit Co.
Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's site using requirements , make the operation more convenient, complete function, stable and reliable data, the testing speed is greatly improved.To meet the needs of all kinds of small medium and large transformer ratio test.
-
CXBC-901 -
Shenzhen Chuangxin Instruments Co., Ltd.
Transformer Turns Ration Tester is applied to measure the voltage ratio and group testing of the three or single phase transformer. All the test results could be printed by the micro printer or saved in the tester.
-
Eltel Industries
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
-
-
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
YDTW\YDTCW series -
Shanghai Jiuzhi Electric Co., Ltd.
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers). The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
-
NEO TELE-TRONIX PVT. LTD
Fully equipped with latest machines and tools, we are a prominent manufacturer and exporter of Transformer Winding Resistance Meter. The meter is used in electrical, power generation and engineering sector for testing transformers. Available in different models, this testing equipment is in strict tandem with industry standards. We use best grade raw materials to manufacture this Transformer Winding Resistance Meter. We offer this resistance meter to clients at economical price.
-
TMS3000 -
Shanghai Jiuzhi Electric Co., Ltd.
The TMS3000 is a computer controlled high precision measuring system for power transformers. The system has distinguished itself in the rugged environment of the transformer test facility. The design ensures that its control and instrumentation function circuits remain unaffected by interference fields.
-
KATC-V2 -
The Eastern Specialty Company
Knopp’s KATC-V2 is a highly accurate state-of-the-art voltage transformer comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement with additional test set cables to fit in the existing Knopp Voltage Transformer Test Systems.
-
NEO TELE-TRONIX PVT. LTD
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
TTRM 102 -
Scope T&M Pvt, Ltd.
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.