Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 751 - 765 of 1014 items found.

  • SMART MEGOHMMETER

    MD-5060x - MEGABRAS srl

    The Megabras MD-5060x is a smart, microprocessor-controlled, 5 kV insulation tester. Besides the conventional measurement of insulation resistances up to 5 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.

  • SMART MEGOHMMETER

    MD-5060e - MEGABRAS srl

    The Megabras MD-5060e is a smart, microprocessor-controlled, 5 kV insulation tester. Besides the conventional measurement of insulation resistances up to 5 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.

  • SMART MEGOHMMETER

    MD-1035e - MEGABRAS srl

    The Megabras MD-1035e is a smart, microprocessor-controlled, 1 kV insulation tester. Besides the conventional measurement of insulation resistances up to 1 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.

  • Synchro to DC Sine / Cosine Converters

    SD - Computer Conversions Corporation

    This unique series of Synchro to DC Converters makes use of advanced digital circuitry techniques to accomplish high speed conversion with extreme accuracy. Transformer isolation as well as balanced line-to-line input impedance is provided for superior and trouble-free system performance, regardless of the input synchro used.

  • Synchro to DC Converters

    Computer Conversions Corporation

    This unique series of Synchro to DC Converters makes use of advanced digital circuitry techniques to accomplish high speed conversion with extreme accuracy. Transformer isolation as well as balanced line-to-line input impedance is provided for superior and trouble-free system performance, regardless of the input synchro used.

  • High Voltage AC/DC Testing Kits (Hipot Kits)

    Technology Products

    HV Testing Kits are used for testing of Motors, Generators, Switchgears, Cables, Transformers and other electrical equipment. These are used for testing & commissioning of HV electrical equipment. High Voltage AC Testing Kits are available in ratings from 25KV to 300KV AC in various mA and KVA Ratings.

  • Rotary Scale Clamp Meter

    ST-600 - Standard Electric Works Co., Ltd

    ● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • AC/DC Laboratory Power Supplies

    PeakTech Prüf- und Messtechnik GmbH

    This AC / DC laboratory power supply has two separately adjustable outputs which can dispense AC/DC voltages from 0 - 30 V as well as DC/AC current 0 - 6 A. Due to the possibilities offered by this device, it is also suitable for the maintenance of small AC circuits, transformers and lights.

  • Integrated Safety Unit For ATOS

    ISU-R - Raytech AG

    Raytech Integrated Safety Unit is a useful device when creating rack mounted transformer observing systems. It supplies Raytech devices with fused electrical power, manages external Interlocks and provides a single interface for an external warning lamp. The whole system can be turned on and off with a single mains switch.

  • CT Burden Tester

    585 - Radian Research, Inc.

    The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.

  • DC Power Supply

    PW-3063R - PINTEK Electronics

    *Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-3063R as high as 0.1v and 0.01A.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.

  • Power Quality Analyzer

    PQM-702 - Sonel S.A.

    *Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V.*With particular emphasis on measurements at low voltage poles, due to the ease of connection.*Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.*Remote control and data transfer through a built-in GSM modem (GPRS).*Anti-theft feature - SMS notification in the event of position change - built-in GPS receiver.*Real-time clock synchronized to GPS protocol.

  • Autotransformer

    T-1007 - Compact Power Company

    The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.

  • Advanced Primary Injection Test Set

    PI-2500 - ETI Precision

    The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.

Get Help