Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 961 - 975 of 1014 items found.

  • High Resistance Neutral Grounding Devices

    Hilkar

    HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.

  • NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783107-01 - NI

    250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.

  • Digital Insulation Testers

    Premier Electrosystems

    Premier Electrosystem's Insulation Resistance test (also known as Megger, Mega Ohm Meter, Million Mega Ohm Meter) indicates whether any corrective maintenance or replacement of installed equipment is necessary, to assess if the newly installed equipment can be safely energized, and to trend the gradual deterioration of the equipment over its service life. Insulation Resistance Test is carried out to ensure the healthiness of overall insulation system of electrical equipment. It reflects the presence or absence of harmful contamination, dirt, moisture and gross degradation. Common areas of application are testing of appliances, wires, transformers, harnesses, motors, etc.

  • Enhanced SCR Power Controller

    Thyro-PX DC - Advanced Energy

    The Thyro-PX DC series shapes the future of the growing hydrogen and DC heating markets. The SCR power controller series takes advantage of the existing Thyro-PX controller card architecture and is available as three-phase units, supports up to 1800 amps DC Current, and offers superior interface options. Integrate operating modes and parameters seamlessly with the 2.8-inch, LED Thyro-Touch display and enable efficient system parameters, loading, and storage via an onboard SD-card. The Thyro-PX power controller is ideally suited for your transformer and resistive loads for glass, metal, and ceramic manufacturing. It is optimal for heating elements in electric furnaces.

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • DC High-Voltage Test Device

    PGK 50 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • Partial Discharge Testing Equipment

    PD-Analyser - Scope T&M Pvt, Ltd.

    This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • 50Hz-100kHz LCR Meter

    Chroma 11022/11025 - Chroma Systems Solutions, Inc.

    The Chroma 11022 and 11025 LCR Meters are passive component testers that can give you the most cost effective alternative equivalent to the high priced meters. They are designed for the demanding applications in production test, incoming inspection, component design and evaluation. Programmable test signal level settings are from10mV to 1V in a step of 10mV, and the VM/IM signal level monitor functions allow you to evaluate your devices at the level you specify. Ten test frequencies of 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, and 100kHz, can be used to evaluate passive components and transformers/ LF coils.

  • Couplers, Repeaters, Bus Switches, Connectors, Cables & More

    Excalibur Systems, Inc.

    Accessories for the MIL-STD-1553 data bus are as much of an interface as the communication card. Therefore at Excalibur we provide a full line of accessories for the MIL-STD-1553 data bus that include, Box/Inline Couplers, Repeaters, Bus Switches, break out boxes, connectors, terminators, transformers and custom cable assemblies. Excalibur uses only premier quality parts from known manufacturers. We constantly test our products to meet our higher standards.If you have a need for an accessory product for your card and it is not listed please contact us to see if it is a product we should be supporting.

  • High Voltage System

    HV-2 - International Electro-Magnetics, Inc.

    *Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.

  • IEEE 1394b/AS5643 Mil1394 (FireWire), Triple-Node Multi-Port, Communications

    FW3 - North Atlantic Industries

    The FW3 function module provides IEEE 1394b/AS5643 (Mil1394) support on each of its three nodes, which are configured as 2 nodes with 3-ports and 1 node with 2-ports. AS5643 defined flight ready robustness and active transformer isolation to enable longer cable lengths (20 meter) between nodes. Together these standards provide the deterministic and redundant communications protocol required for Vehicle System (Flight Control) Networks. The FW3 multiple ports per node configuration allows the user to create tree, daisy-chain and looped topologies needed to optimize cable length and weight while creating redundancy.

  • Three Phase Power Analyzer

    Model TFT780 - Gopal Electronics

    Three Phase Power Analyzer PA700TFT is multi-range power Analyzer with basic 0.05% R+R accuracy. 8 range of voltage, 8 range of current and total 64 range of power and power factor gives more accurate result at low power factor. It has waveform mode to check the waveform of voltage and current. As well it has B/H curve mode where user can check live b/h curve of the transformer under test. The gap less four-quadrant power measurement technique gives better accuracy at distorted waveforms or AC drive (VFD) operated power supply.

  • Digital LOOP/PSC/LOAD Tester

    2811 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Displays and sound warning if external voltage present.● Displays mains voltage, scroll trough menus.● Checks wiring integrity (LEDs and display).● Single button operation.● Auto-off/auto-ranging.● Combined prospective short circuit current, PSC and LOOP tester.● Built-in carry case, test leads in separate pouch.● Loop test for L-E and L-N and PSC.● Voltage test L-N and L-E.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for special orders.● 60Hz available on request.

  • 903 Benchtop Three Phase 40A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.

Get Help