Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 916 - 930 of 1014 items found.

  • Test & Measurement Products

    Cole-Parmer Instrument

    We offer a broad range of test and measurement devices for your scientific, educational, industrial, and process applications. We carry the test and measurements tools you need to analyze, validate, and verify measurements in your electronic and mechanical systems, ensuring compliance to quality assurance and quality control programs. Our selection features portable and bench oscilloscopes, multimeters (DMMs), clamp meters, megohmmeters, stroboscopes and tachometers, power transformers, along with precision meters for humidity, moisture, light, airflow, weather, and vibration.

  • Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase

    SL1201A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase

    SL1202A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Scienlab Regenerative 3‑Phase AC Emulator

    SL1200A Series - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Regenerative AC Emulator, 1200 VAC, 65 A, 90 KVA, 3‑Phase

    SL1213A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Regenerative AC Emulator, 1200 VAC, 32 A, 45 KVA, 3‑Phase

    SL1212A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 90 KW / 135 KVA

    SL1215A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Regenerative AC Emulator, 600 VAC, 125 A, 90 KVA, 3‑Phase

    SL1203A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • Scienlab Dual-Range Regenerative AC / Grid Emulator, 600 / 1200 VAC, 63 / 32.5 A, 45 KW / 66 KVA

    SL1214A - Keysight Technologies

    The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.

  • HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY

    xPS Series - Carl E. Holmes Company

    High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)

  • Military-Style DC Solid-State Relay for High-Current Pulse Load Applications

    Part No. M33-2N - Teledyne Defense Electronics Relays & Coax Switch

    The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;

  • AC Electronic Load

    ET Power Systems Ltd.

    The electronic AC loads cover a wide variety of different voltage, current and power ranges. All the AC loads are programmed with 11 different sine, square and DC waves. With 5 crest factor variations of each, a total of 55 waveforms are available. An external input is also provided to enable the user to amplify signals from a waveform generator.AC Loads allow real world operating conditions to be simulated. Typical applications include circuit breaker, transformer & UPS output testing along with general laboratory and research work.

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • Primary Injection Test Set

    PI-6000 - ETI Precision

    The PI-6000 is a rugged & durable primary injection test set capable of testing circuit breakers up to 6,000 amperes frame size. It incorporates an output transformer with dual primaries to facilitate its use on power sources of 480 VAC as well as 208-240 VAC. The unit also includes dual secondaries to provide optimal impedance matching to a wide range of circuit breaker sizes. An internal voltage sensor automatically configures the AC control power section to be energized only when properly configured for the applied voltage.

  • Portable Moisture in Oil and Dewpoint Analyzer

    DOMINO USS - Doble Engineering

    The Doble DOMINO USS (Ultimate Sampling System) gives you a fast, efficient way to measure water content in oil and/or the dewpoint of a gas.The DOMINO USS is a portable system that connects quickly and easily to transformer valves or other oil-filled electric devices.Operating on AC power supply or with its rechargeable battery, you will have accurate readings in six minutes or less.The DOMINO USS is customizable to your testing requirements, coming with either a moisture-in-oil sensor, a moisture-in-gas (dewpoint) sensor, or both.