Showing results: 1186 - 1200 of 2564 items found.
-
CPCI-ISC8 -
ALPHI Technology Corporation
The CPCI-ISC8 is an intelligent DSP based serial communication board. This 3U board is based on the CPCIIPC product and has been modified to remove the IPinterface and to support additional I/O features. The CPCIISC8 provides mechanical support and the electrical interfaces for an I/O mezzanine board. Multiple CPCI-ISC8 boards may be installed in a single system.
-
ETL-35 -
Kharkovenergopribor Ltd.
ETL-35 is a cable test van designed for testing electrical substation equipment.Apart from cable insulation withstand testing with DC (rectified) voltage up to 60 kV and ability to measure very small leakage currents, the system can be used for testing various objects with small electrical capacitance with AC voltage of up to 100 kV and measuring dielectric dissipation factor (Tan Delta) at industrial frequency.
-
Viola -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR viola. The portable and powerful viola high-voltage testing and diagnostics device is used for cable and cable sheath testing of medium-voltage cables up to 35 kV and electrical equipment. Another function is insulation testing on electrical equipment.* High performance and compact* Precise and non-destructive determination of the cable condition* Easy and quick test setup* Automatic testing and diagnostic sequences
-
ASTM D257 -
National Technical Systems
These test methods cover direct-current procedures for the measurement of dc insulation resistance,volume resistance, and surface resistance. From such measurements and the geometric dimensions of specimen and electrodes, both volume and surface resistivity of electrical insulating materials can be calculated, as well as the corresponding conductances and conductivities. These test methods are not suitable for use in measuring the electrical resistance/conductance of moderately conductive materials. Use Test Method D4496 to evaluate such materials. This standard describes several general alternative methodologies for measuring resistance (or conductance). Specific materials can be tested most appropriately by using standard ASTM test methods applicable to the specific material that define both voltage stress limits and finite electrification times as well as specimen configuration and electrode geometry. These individual specific test methodologies would be better able to define the precision and bias for the determination.
-
GAO Tek Inc.
GAOTek provides state of the art, professional grade Ohmmeters for sale to the United States, Canada and Globally. GAOTek Ohmmeters are portable instruments that accurately measure electrical resistance between two points on a circuit. The Ohmmeters have their own power supply through their own battery, and are needed when the two probes (red: positive side of circuit, black: negative side of circuit) are connected to the two points in the circuit where the desired measurement is to take place. The circuit is turned off, which is when the ohmmeter sends its own current through the circuit. Units of Ohms, symbolized by the Greek letter Ω (Omega), are used as a unit of measure when measuring electrical resistance. In accordance with Ohm’s law, when the current is passing through a circuit is at its maximum, the resistance is said to be the smallest.
-
Keystone Compliance
An EMI site survey is an independent assessment of the potential Electromagnetic Interference (EMI) risks that might interfere with an implantable electrical device such as a pacemaker or defibrillator. The assessment should be completed by a qualified and accredited independent test lab such as Keystone Compliance and in collaboration with the employer, manufacturer of the device, patient and physician. A site survey is conducted by taking various electromagnetic measurements throughout the facility. Keystone Compliance uses a broad range of industry-accepted standards and specifications to determine which electromagnetic fields exist. Following completion of the on-site survey, Keystone Compliance provides the customers with a detailed site survey report that will help identify EMI sources and zones with the potential to interact with an implantable electrical device. This information should then be shared with the physician and employer to develop an action plan to reduce potential negative effects to the patient’s health.
-
TRACER 1.0 -
Tweddle Group
TRACER creates vehicle- and fault-specific diagrams on the fly. It can diagnose the probable cause of failure in a network of wiring harnesses and modules and lets technicians choose a CAD view of the wiring layout to find the precise failure location (down to a specific pin), so they can correct the issue efficiently. Tracer saves labor costs, overhead costs and helps avoid collateral damage. TRACER streamlines ELT and dealership repair. It's helpful for all vehicles, particularly new models, where technicians lack the familiarity to assess and resolve electrical issues in a timely manner. TRACER also makes aberrant anomalies a thing of the past—when a vehicle rolls down the line with a never-before-seen combination of electrical failures, resolution becomes a matter of routine. TRACER dramatically reduces effort and increases efficiency.
-
National Technical Systems
Surface Insulation Resistance (SIR), as defined by IPC, is the electrical resistance of an insulating material between a pair of contacts, conductors, or grounding devices that is determined under specified environmental and electrical conditions.In respect to the world of printed circuit boards (PCBs) and printed circuit assemblies (PCAs), SIR testing—also commonly referred to as Temperature Humidity Bias (THB) testing—is used to evaluate a product’s or a process’ ability to resist “failure” by means of current leakage or an electrical short (i.e., dendritic growth). SIR testing is typically performed under elevated temperature and humidity conditions—such as 85°C/85% RH and 40°C/90%—with periodic insulation resistance (IR) measurements obtained.
-
Vishay Intertechnology, Inc.
A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.
-
NEPTUNE -
HT Italia Srl
NEPTUNE is a mix of technology including an instrument for electrical safety testing (insulation up to 1000V and continuity with 200mA), a Harmonics analyzer and a TRMS multimeter.
-
NEO TELE-TRONIX PVT. LTD
This testing set is an automated instrument, widely used for measuring electrical characteristics of insulating liquids, transformer oil and other insulating material samples.
-
1673 -
Peaceful Thriving Enterprise Co Ltd
Check on 6-12V systems. Safely test standard primary automotive circuit and on-board computer controlled electrical system without damaging the micro-processor.
-
72-9170 -
Tenma
Quickly identify wires and tests continuityFits in any pocket or tool kit Invaluable in all audio, video, network, telecom and electrical installations
-
EPM 2000 -
GE Digital Energy
The EPM 2000 meter measures more than 40 electrical power parameters providing a low-cost, multifunction monitoring solution for industrial and power generation applications. EPM 2000 can easily be mounted in a panel for generator monitoring, substation automation and more. Meter can also provide data to RTUs, PLCs and other control devices.
-
#TFT100 -
NSI Industries
Stop guessing about circuit breaker tripping issues. See why, when and where a circuit breaker trips. For the first time, you can detect the type of fault, and locate the position of an electrical “event” that causes intermittent and persistent circuit breaker trips, and No Fault Found (NFF) conditions. The critical information needed to reduce […]