Showing results: 976 - 990 of 2551 items found.
-
Chroma Systems Solutions, Inc.
The purpose of safety testing medical electronic equipment is to be sure that a device is safe from electrical hazards to the patient and caregivers. There are a number of UL, European and Canadian standards that serve as the ruling body on how medical products will be tested, one in particular, IEC60601 (the International Electrical Safety Standard for medical electronic equipment) is experiencing “global harmonization,” meaning it has been accepted and implemented around the world. The IEC60601 standard is mainly intended for product development where safety considerations must be taken into account early in the design phase of a product, however much of it is applied to production line testing since it is the only way for a manufacturer to be sure they are shipping safe product.
-
3010HP, 3025HP & 3050HP -
Jabbals
The DC Hi-Pot test is an important part and parcel of the electrical safety tests mandated by standards organization world-wide. More than 80 per cent of faults in electrical and electronic systems are due to weak insulation caused by environmental factors such as dirt, grease, temperature stress, humidity, etc that affect the dielectric strength of the insulation material.
-
SCR ELEKTRONIKS
The Ball Pressure Apparatus is designed to perform test specified in IS Standard where resistance of insulating material to elevated operating temperature is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaries, motors, connectors, etc. It is a precision engineered test instrument for use by safety and compliance testing laboratories.
-
SE -
Xitron Technologies Inc.
Safety First! Vitrek’s SE Series of high voltage safety enclosures are designed to prevent the potential of electrical shock when performing electrical tests. The enclosure comes standard with a magnetic safety interlock switch and chassis ground connection that must be wired from the safety tester to the safety enclosure by the end customer for safe operation.
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
A non-contact voltage tester is the safest way to make sure the power is off without touching any wires. Before you open an electrical box, you should: - cut off power to the outlet at the main electrical panel - confirm you turned off the right circuit This is where the non-contact voltage tester comes in handy.
-
LTX-510 -
Scitec Instruments Ltd
The LTX-510 Electrical to Optical Converter is a convenient device that is intended to transmit analogue or digital signals to a remote location via a multi-mode fibre optic cable. The main applications are situations in which the signal of interest has a high common mode voltage with respect to the measuring equipment.
-
ELETOM -
PASI srl
ELETOM is a software that performs complete 2D inversion (and not the simple iterative deconvolution of the pseudo-sections) of surface electrical surveys with any measurement array (Wenner, dipole-dipole, pole-dipole, pole-pole, user defined arrays, mixed arrays) with a maximum of 64 electrode positions that can be added by the user as required.
-
HPRS Series -
IET Labs
The HPRS Series resistance decade boxes employ state-of-the-art precision resistors of various types for high accuracy, high stability, and low temperature and power coefficients of- resistance. High-power resistors within the unit are made available without sacrificing other electrical properties.
-
AMIC-10 -
Amperis sl
The AMIC-10 digital insulation resistance meter is used for direct measurements of the insulation resistance of electrical equipment working with voltage up to 1 kV. In addition, this meter makes it possible to measure compensation and protective connections, low-voltage resistance measurements and DC and AC voltage measurements.
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Covers all major standard applications in the control cabinet. It is as unique as our well-known high-end products, but much cheaper. Thus, the Basic Line is ideal for all electrical equipment, engineering companies and many other industries where very good just good enough.
-
MODF Rack -
Lifasa - International Capacitors, SA
The MODF-RACK control units include, in a compact form, all the components necessary for the operation of a step of a capacitor bank with filters. MODF-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
MOD Rack -
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
ABB Ltd.
Electrical rotary actuators with rated torque of 100 Nm ... 16000 Nm for the operation of final control elements with preferably 90° rotary movement such as flaps, cocks, dampers, etc.A lever / linkage bar assembly transfers the torque or the actuator is directly coupled to the cock flange.
-
STA-2 -
Malcom Co.,Ltd.
Necessity for on-site lead-free solder management.Applicable for RoHS Directive. (WEEE: Directional on Waste from Electrical and Electronic Equipment, Pb mixed rate under 0.1%) Lead measurement accuracy is +/-150 PPM. Manage increases and decreases of Pb and Cu in your lead-free solder.
-
Acces I/O Products, Inc.
Relay is the name for a switch that is operated electro-mechanically or electronically. Their main task is to make and break connections to control the flow of current in electrical circuits. They’re used for various purposes ranging from validating semiconductors to interfacing low power computers or microcontrollers with high power machinery.