Filter Results By:

Products

Applications

Manufacturers

Showing results: 1981 - 1995 of 2564 items found.

  • Linear Position Sensors

    Positek Limited

    Positek linear sensors use our own patented inductive sensing technology packaged in very durable housings. With a comprehensive range measuring from 1mm to 800mm and most products available with intrinsically safe approval. Hydraulic and pneumatic cylinder applications can be satisfied either with the P100 style cylinder sensor, the internally mounted P106 linear sensor or any of our other externally mounted linear sensors such as the stand alone P101. For submerged applications we offer IP68 sealing to 10 bar from our S114 and S115 submersible linear sensors and 350bar from our S125. The complete range of linear sensors is very customisable with many mounting, electrical and connection options. Customisation of most of our Linear, Rotary and Rilt sensors is routine given the excellent flexibilty of our sensing technology.

  • Oscilloscopes

    Extech Instruments Corporation

    A Digital Oscilloscope offers a range of capabilities for effective troubleshooting of electronics and electronically controlled electrical systems. With 20 MHz bandwidth and conveniences like auto-set which optimizes the position, range, time base, and triggering to assure a stable display of virtually any waveform, this can be used in field repairs or bench duty. To identify subtle problems, Peak Detect features a fast 50 ns glitch capture. Core functions like XY Mode, FFT function, Trigger Hold off, Waveform Math, Averaging Mode and Persistence Mode all ensure you can confidently troubleshoot problems using a variety of approaches. To start up recurring testing routines, you can store and recall up to 4 waveform screens and setups to save time from job to job.

  • Counter Electrodes

    ALS Co., Ltd

    For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.

  • Inverters FERVE

    FERVE s.a.

    FERVE has a new range of products, pure sine wave inverters. These investors next generation transform 12V DC to AC 220-240V, and being pure sine wave can be used in devices with motor, simple, complex or sensitive electronics. Thus, from a battery making energy available to electrical installations, tools, appliances, etc. All it controlled by microprocessor and with high quality performance.

  • Multifunction Calibrators

    Fluke Calibration

    These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.

  • AMIDA VCSEL Tester

    Amida Technology, Inc.

    AMIDA VCSEL tester can be divided into three parts: LIV measurement system, Near Field measurement system and Far Field measurement system. To achieve the above three measurements, in addition to the necessary optical components and optical instruments, the core technology is to provide fast and stable current pulses to drive the VCSEL laser diode to emit light, and then to test various optical and electrical properties

  • Magnetic Resonance Instruments

    Integrated Dynamics Engineering

    MRI systems represent a significant investment. As magnetic resonance images can be distorted by electromagnetic fields, frequently the location is isolated by passive shielding to somewhat insulate the detectors from image distorting EMI. But for a fraction of the cost of the machine an active EMI compensation can fully protect the image from damaging fields generated by other electrical equipment, passing traffic, elevators or other nearby equipment.

  • Electricity Meter Test Equipment

    Applied Meters, a.s.

    The Reference Standard RS is precision standard meter in single- and three-phase version for electrical power and energy measurement. It is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any true or artificial mode of operation in three phase system and is capable to evaluate individual quantities in any phase

  • AC Load Bank (Resistive)

    K-1000 Resisitive - Kongter Test & Measurement Co., Limited

    The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.

  • Loop Meter

    MZC-310S - Sonel S.A.

    The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.

  • Multi-Operational Surge Tester

    MB Model - PJ Electronics, Inc.

    Bench all-in-one versatile Multi-Operational Surge Tester that you need for all of your electrical insulation testing. The Hi-Pot tester has separate L.E.D. panel meters for direct readout (voltage and leakage current) so that no interpolation on the scopes display is ever needed. This MOST can surge test extremely low inductance windings, DC armatures, etc.

  • PITOT STATIC TESTER

    ADSE 745 - ATEQ Aviation

    The ADSE 745 caters fully for all aircraft types and the different electrical power supplies.It can be used for testing high performance civil and military aircraft, fix and rotary wing. The multi-pressure outlets option can suit the more complex pilot-static-systems. This Pitot Static Tester is designed primarily for flightline use to cover the testing of all barometric and manometric pressure instrument systems.

  • Manual Switch Boxes

    Robson Technologies, Inc.

    RTI's manual switch box is a portable and versatile test solution for quick IC electrical verification tests. RTI's 96-pin manual switch boxes integrate with a variety of test configurations that are customized to your test and device needs. It requires no software and connects directly to an external power supply for bias test, and performs quick comparison tests using an A/B relay box.

  • Non-Contact (Pulse-Voltage Excitation Method) Ultra-Low Sheet Resistance Measurement System

    PVE-80 - NAPSON Corp.

    *No damage measurement by non-contact Pulse-Voltage excitation method*Easy to measure & carry around, Removable stage plate*Easy operation and data processing by PC with Software*Measurement result can shown by 3 types of measurement unit (Sheet resistance[Ohm/Sq], Electric conductivity[S/cm], Electrical conduction[S])*Pulse-Voltage excitation method : Pat. No.5386394 Joint development with Chiba Univ.

  • Micro Ohm Meter 200A

    Micro Centurion II - Raytech AG

    Raytech Digital Micro ohm meter, Micro-Centurion II, was designed for high degree of accuracy to measure very low resistances. This technology was then packed into a portable test system to be used by apparatus manufacturers, rebuild shops, and electrical maintenance crews. This intelligent system has an easy to use operation screen, which allows quick selection of the current level and resistance level to be measured.

Get Help