Filter Results By:

Products

Applications

Manufacturers

Showing results: 1786 - 1800 of 2560 items found.

  • Ringwave Generators

    Hilo Test

    Ring wave or oscillatory wave are pulsed onset, damped oscillatory waves as it can be but triggered in low-, medium- and high-voltage systems in data networks as a noise voltage by switching operations, lightning strikes and insulation breakthroughs in cable runs. The Ringwave Immunity tests for electrical equipment are described in the basic EMC standards.

  • Tan Delta and Capacitance Tester

    TDC3100L - VA Technology Co. Ltd.

    Tan Delta and Capacitance Tester TDC3100L is fully automatic 12 kV insulation power factor/dissipation factor (tan∂) test set designed for evaluating the nature and quality of electrical insulation materials and high voltage systems such as transformers, bushings, circuit breakers, cables and windings of rotating machines etc..

  • Selenium Surge Suppressor

    Carl E. Holmes Company

    Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.

  • Replacement Selenium Surge Suppressor Specialists

    Carl E. Holmes Company

    Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.

  • 160W Switching Power Supply - Single Output Continuous Switching Power Supply with USB

    Extech DCP42 - Extech Instruments Corporation

    DCP42 is a 160W Switching Power Supply. Single Output Continuous Switching Power Supply with USB offers high efficiency electrical power conversion for greater energy conservation and lighter weight. Complete with power cord, software, and USB cable. Software includes DC ramp and waveform generator.

  • Custom Assembly Automation

    PrimeTest Automation

    Our team of experienced mechanical, electrical, and software engineers fabricate all types of assembly systems, ranging from complicated multi-step assemblies to simple single step assemblies. We have a full machine shop to manufacture systems from materials such as plastic, aluminum, steel, and stainless steel. All our systems are expandable and allow for future enhancements with modular components. They are available with a variety of options, including human machine interfaces, welding, marking, packaging, and test equipment. Additional features include emergency stop safety circuitry and hard guarding. All fabricated systems are provided with the necessary pneumatic and electrical system layouts in addition to the associated documentation. Our services also include onsite setup, training, and support operations.

  • 3-Phase AC Voltage Transducer

    ENVIROMUX-PT3-600 - Network Technologies Inc

    Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.

  • 30A True RMS AC/DC Mini Clamp Meter

    Extech 380942 - Extech Instruments Corporation

    The compact Extech 380942 is a 30 Amp mini AC/DC clamp meter. The clamp meter has a remarkable 0.1mA resolution (AC), very low-current sensitivity, and a small diameter jaw designed to reach into small areas. The 30 Amp range with 0.1mA (AC) and 1mA (DC) resolution is optimized for finding problems where very low current variances would be missed by standard clamp meters. This mini clamp meter is useful for troubleshooting tasks in plant maintenance, electrical, HVAC, and telecom work, as well as residential electrical, fleet maintenance, marine, and motorcycle repairs. This CAT III-rated True RMS mini clamp meter comes with test leads, 2 AAA batteries, soft carrying case, and user manual.

  • EPON OLT ( Optical Line Termination )

    OLT-1840 - Hangzhou Huatai Optic Tech. Co., Ltd.

    OLT-1840's Optical Line Terminal (OLT) adopts GiGA Ethernet Passive Optical Network (EPON) technology. It is a compact chassis with L2/L3 GiGA switching and routing function. All the functional components are modularized design and it supports hot-plugging with plugging and playing. 1~8 pieces of GiGA optical port or electrical port are optional in the uplink port, which provides a direct optical interface for the Ethernet/IP network core. 40 pieces of EPON optical port are optional in the down link port. Through a passive optical Network (PON), an optical Network unit link (ONU),it can provide final transmission with bandwidth up to 1Gbps for the user.

  • Mechanical Test Head Housing

    esmo AG

    a result of more than 10 years' experienceavailable with integrated manipulatorfully integrated docking and board lockingtest housing mechanics design as per customer specificationssuitable for individual and high-volume productionstandard and customized dimensionsno limitation in size and electrical power capacitiesquick and easy locking and unlocking process for board changelarge application space load boardoptional number of channel boards as per customer specificationsfamily/DUT board connection achieved by high-end double-ended spring probes - 50 Ohmhigh-end cooling fansfacilitated adaptation with all available manipulator solutionsdocking design in compliance with customer internal docking standards/dimensionsdocking force as per customer specificationscenter of gravity fully compensated

  • SY018 Voltage To Current Converter

    Synectic Electronics

    The SY018 DIN rail Voltage to 4-20mA signal converter is used to communicate analogue signals over long distances where electrical interference may be a problem. This solution is often used in the process control industry to collect the analogue values from a wide array of remote sensors. The converter is valuable because current signals are much less susceptible to noise than voltage signals. A voltage signal can be converted to current and broadcast over a long distance.  4-20 mA transmitters are common in the industry and used with high-quality sensors. The resulting signals can be use in controlling drives or to trigger instruments that have settable thresholds and limits.

  • Vital Sign Sensing

    ams AG

    The biometric sensors product family features first-of-its-kind integrated optical sensor modules which include algorithms for heart-rate measurement, photoplethysmography (PPG) and electrocardiography (ECG). The modules are ideal for a wide range of end products including wearable devices, medical monitors, industrial equipment and mobile devices. Biometric sensors from ams are able to achieve the highest accuracy ratings in the industry because of a combination of a low-noise analog and optical front-end and custom ams software and algorithms. Drawing on expertise in optical sensing in mobile devices, ams provides OEMs with electrical, mechanical and optical design guidelines to enable designers to quickly realize a successful

  • Waveguide Twists

    Fairview Microwave Inc.

    Fairview Microwave’s precision waveguide twists operate from 18 to 110 GHz across seven frequency bands with waveguide sizes ranging from WR-42 (18 GHz) to WR-10 (110 GHz). Our portfolio of waveguide twists feature gold plated brass construction that offers excellent electrical performance with VSWR as low as 1.02:1 and insertion loss as low as 0.2 dB. Both 45° and 90° waveguide twists are available from stock, with the 45° versions being available in both right hand and left hand twist configurations. All of our waveguide twists are in-stock and ready to ship today!

  • Advanced Thermal Imaging Camera

    FLIR E96 - Teledyne FLIR

    The FLIR E96 is our first pistol-grip camera with 640 × 480 thermal resolution so inspectors can survey high-voltage, hazardous targets safely and quickly diagnose electrical and mechanical failures. Interchangeable AutoCal™ lenses offer complete coverage of near and distant targets, with the laser distance meter ensuring the crisp focus needed for accurate temperature measurement. The onboard FLIR Inspection Route runs pre-planned routes to help inspectors stay organized when surveying large or multiple locations. FLIR Ignite provides automatic uploading of E96 images directly from the camera to the cloud for easy, secure storage and sharing.

  • Standing Loss Test System/ Star Rating Calculator for Geyser

    Premier Electrosystems

    Premier Electrosystems' Standing Loss System is used to calculate the energy consumption measurement of a filled water heater, after steady state conditions have been reached when connected to electrical supply and when no water is drawn for a minimum of 48 hours.The star rating for the electric geysers is given based on the standing losses. Standing loss or heat/energy loss of a water heater to the surrounding in 48 hours is an important factor used by BEE (Bureau of Energy Efficiency) to decide on star rating of a water heater. The unit of Standing Loss is Energy consumed per 24 hrs for a difference of 45 ° C (kWh/24 hrs/ 45 ° C).

Get Help