Showing results: 346 - 360 of 8764 items found.
-
FOD 3106 -
Fiber Optic Devices Ltd.
The FOD Dual LED modules are designed specifically for test instruments application. They allow to have one output for two wavelengths in compact handheld device without couplers. The Module have an original ceramic ferrule that allows to incorporate the module on the front panel of a device and keep the access to the front face of the ferrule for cleaning and polishing.
-
DCOAX -
Andeen-Hagerling, Inc.
Very high precision, three-terminal capacitance measurements can be affected by the self-inductance of the test cables, mainly at higher capacitance values. Magnetically induced noise can also reduce the quality of measurements. The cable now offered by Andeen-Hagerling both minimizes these problems and provides a way to standardize the residual self-inductance.
-
EH118 -
MVG EMC
EH118, a dual-ridge horn antenna that will operate from 1 to 18 GHz. This antenna has a balanced, smooth antenna factor curve that extends all the way to 18 GHz, a reduction of higher order modes on the aperture, and low return loss (SVSWR). The EH118 is applicable for commercial, military and automotive test standards and will include applicable calibrations. The EMC dual-ridge horn antenna offers these key features: single linear polarization, smooth/balanced gain with frequency, low return loss /VSWR, and ultrawide bandwidth (18:1).
-
Walts Co., Ltd
Advanced Dummy Test Wafers/Chips available with over 35 different chip designs and choices of 11 different material configurations as well as kits complete with test vehicles. Custom-make test production of TEG wafer/glass (TEG=Test Element Group). Design and provide custom-make test kit.
-
DVB-T and DVB-T2 -
EDB GmbH
DVB-T and DVB-T2 Coverage Measurement and Drive Test solutionb by using of common RF- and GPS- receiver hardware. The solution turns a laptop into a powerful coverage measurement and drive test device.
-
2527 Series -
Instron
Dynacell is the world's first truly dynamic load cell, designed from the outset for measuring dynamic loads. Dynacell introduces the following advantages: *Reduces dynamic load errors which can be a significant percentage of reading*Increases productivity by allowing higher frequency operation while maintaining test validity *Improvements such as doubling the frequency are common
-
UI-FT11 -
Unuo Instruments
Dynamic Footwear Water Penetration Tester is used to test all kinds of finished shoe water resistance ability in flexing condition.
-
ObserVIEW -
Vibration Research Corporation
View, edit, and analyze waveforms from recorded or live data. This powerful and efficient vibration analysis software package includes specialized modules for waveform recording and test generation.
-
900 Series -
Data Physics Corp.
The new SignalCalc 900 Series software makes the process of defining a test, making measurements, analyzing data and generating high-quality reports easier than ever before. All setup, project, test article, and customer information is saved along with measurement data in a database. Easily search for data from different test runs and test types for analysis and report generation.
-
DS5 1000A -
ipTEST Limited
The M2 DS5 1000A dynamic switch test generator assembly is one of the Mostrak-2 family of test generators from ipTEST. It performs single and double pulse inductive load switching, diode recovery and short-circuit tests on MOS and IGBT discrete power semiconductor devices up to 1200V and 1000A.
-
IGAsorp -
Hiden Isochema Ltd
The IGAsorp is a fully automated compact benchtop DVS analyzer, for fast and accurate vapor sorption measurements using the dynamic flow technique for water and organic solvents. Measured vapor uptake isotherms and kinetics are used to characterize, test and evaluate materials in precisely defined environmental conditions.
-
FPS 2700 | VP 230048 -
Maschinenbau Haldenwang GmbH & Co. KG.
The FPS 2700 roller set is used in test centres and is suitable for vehicles with a single driven axle. It was designed for the exact measurement of the exhaust gas behaviour of vehicles during their transient emission test and permits a driving resistance simulation for the exhaust gas tests ASM-5015 and ASM-2525 (Acceleration Simulation Mode) in accordance with the specifications BAR '97. As a result of the increased tractive force of its eddy current brake, the FPS 2700 is additionally suitable for power measurements at constant speed and constant tractive force.
-
RD-22 Ultra -
Radian Research, Inc.
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
BK2121 -
BaKo Co., Ltd
The BaKo Type BK2121 was developed in response to Apple’s need to maintain quality control in earbuds which contain function controls and an internal microphone, designed to be used with newer IPods. It is a compact, easy to setup, easy to use machine with a short test time that you can use to functionally validate each earbud unit as it comes off the product line.
-
MRU-120 -
Sonel S.A.
* earth resistance measurment with 3-pole,4-pole method, * earth resistance measurement without disconnecting measured earths (using clamp), * continuity of equipotential bondings and protecting conductors * two clamps earth resistance measurement without auxiliary test probs, * earth resistivity measurement,