Showing results: 2401 - 2415 of 8764 items found.
-
CENTER 110 -
Center Technology Corp.
3-3/4 Digits Display, Autoranging, High Speed Bargraph, Max/Min Function, REL Function, AC/DC 10A Test
-
-
Crest Test Systems Pvt. Ltd.
HV Test, which is also known as Hipot Test – short form of high potential – is used to test the insulation quality of the auxiliary circuit of circuit breakers. The HV Test is useful in finding damaged insulation, stray conductive materials around the conductors, and problems due to terminal spacing and tolerance errors in cables.
-
GPS Prüftechnik GmbH
GPS Prüftechnik offers a wide range of mechanical adapters. These are mostly used for functional tests.
-
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
Cambridge Instruments & Engineering Co.
“CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.
-
UTP 5065 -
NOFFZ Computer Technik GmbH
Radar sensors are core elements to realize autonomous driving. The UTP 5065 radar test system from NOFFZ Technologies has a compact vertical design and contains everything needed to allow State-of-the-Art measurement and sensor calibration. The test bench setup and component selection are tuned to get best possible results for highly accurate and cost-efficient testing in production of automotive radar sensors.
-
NOFFZ Computer Technik GmbH
Increasing customer requirements, shorter product cycles and higher time to market demands dramatically influence the long-term goals in software development. With the Universal Test Platform Software Suite (UTP Suite), we introduce a robust standard that features a great set of tools for configuring, developing, analyzing, debugging and executing test sequences.
-
6900 -
KANOMAX USA, Inc.
Kanomax has developed the most advanced Duct Air Leakage Tester (DALT) for commercial duct systems. It’s designed to be simple to use, accurate, and extremely convenient. The instrument provides step-by-step duct leakage test configuration and automated leakage testing based on the SMACNA HVAC Air Duct Leakage Test Manual, and is accurate to ±2.5% of reading. Though built tough with an on-board, powerful motor, the DALT 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site.
-
DIF-KIT -
KANOMAX USA, Inc.
The Kanomax tracer gas diffuser kit is used in performing tracer gas tests in accordance with ANSI / ASHRAE Standard 110. The diffuser is designed to the specifications of standard drawing #110-83M.
-
RNT-5A -
Neutronics Manufacturing Co.
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
Neutronics Manufacturing Co.
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
-
Neutronics Manufacturing Co.
Nmc's high voltage test sets are manufactured as per the customers requirement ranging from 5kv-100kv ac or dc.
-
Neutronics Manufacturing Co.
We are engaged in manufacturing, supplying and trading an exhaustive range of High Voltage Oil Test Set, which is developed under the constant supervision of our team of experts. This equipment is acknowledged for its optimality in performance and quality.