Showing product results. 1 - 15 of 62 products found.
-
CMP-401 - Sonel S.A.
DC current measurement and AC current.AC/DC voltage measurement up to 600V.Resistance measurement and continuity test: * continuity test with acoustic signalling (beeper) for resistance below 50.Temperature measurement (Fahrenheit and Celsius units).
-
CMP-400 - Sonel S.A.
The CMP-400 meter is a small portable instrument for direct measuring of alternate current up to 400 A. The meter, when used with additional measurement cables, enables measuring the AC/DC voltage up to 600V. It can also measure resistance with acoustic continuous signal.
-
CMP-1006 - Sonel S.A.
The CMP-1006 meter is a portable instrument for direct measuring of alternate and direct current up to 1000 A. The meter, when used with additional measurement cables, enables measuring the AC/DC voltage. It can also measure frequence, capacitance and resistance with acoustic continuous signal.
-
CMP-200 - Sonel S.A.
The CMP-200 meter is a small portable instrument for direct measuring of AC/DC current up to 400 A. The meter, when used with additional measurement cables, enables measuring the AC/DC voltage up to 600V. It can also measure resistance with acoustic continuous signal.
-
MRU-21 - Sonel S.A.
* earth resistance measurment with 3-pole method, * measurement of continuity of equipotential bondings and protective conductors with auto-zero function - with current 200mA, * resistance measurement using 2-pole method.
-
MRU-200 - Sonel S.A.
MRU-200 is the only meter in the market which uses all measurement methods.Possible measurements:- earth resistance measurment with 2-pole, 3-pole,4-pole method,- impulse earth resistance measurement, two kinds of measuring impulse 4/10s, 10/350s,- earth resistance measurement without disconnecting measured earths (using clamp),
-
MRU-120 - Sonel S.A.
* earth resistance measurment with 3-pole,4-pole method, * earth resistance measurement without disconnecting measured earths (using clamp), * continuity of equipotential bondings and protecting conductors * two clamps earth resistance measurement without auxiliary test probs, * earth resistivity measurement,
-
CMM-30 - Sonel S.A.
The CMM-30 model is a device from a new generation of industrial multimeters that combines versatility, modernity and extraordinary durability.
-
MPU-1 - Sonel S.A.
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.
-
LXP-10B - Sonel S.A.
The new LXP digital light meter family allows for a very precise measurement of illuminanace. Thanks to very high resolution (resolution 0.01 lx ) allows for escape route emergency light measurement. All of three light meter have built-in memory for measurement result storing, and additional function making work much easier.
-
LXP-10A - Sonel S.A.
The new LXP digital light meter family allows for a very precise measurement of illuminanace. Thanks to very high resolution (resolution 0.001 lx ) allows for escape route emergency light measurement. All of three light meter have built-in memory for measurement result storing, and additional function making work much easier.
-
LXP-2 - Sonel S.A.
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
MZC-304 - Sonel S.A.
# Measurements of impedance in a short circuit loop.- L-PE circuit,- L-N, L-L circuit,- L-PE(RCD) circuit - without tripping the circuit breaker > 30mA.# Low voltage resistance measurement:- continuity measurement - DC current +200mA with wire resistivity reset- low current resistance measurement with accoustic signalling,
-
MMR-6500 - Sonel S.A.
The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
MMR-6700 - Sonel S.A.
The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.