  • 4- Channel PXI Source Measure Unit (SMU)

    GX3104 - Marvin Test Solutions, Inc.

    The GX3104 is a precision 3U PXI module that forces and senses both voltage and current over a range of ±20 V and up to ± 1 A ( channel 1) with channels 2- 4 capable of supplying up to 500 mA. Total available output current from the module is 1A. The four channels are electrically isolated from the PXI power supply and share a common, isolated ground.

  • NI-9485, 8-Channel, SSR Relay, 60 VDC/30 Vrms, 750 mA C Series Relay Output Module

    779600-02 - NI

    The NI-9485 allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices. Each channel provides access to a solid state relay (SSR) for switching voltages up to 60 VDC/30 Vrms with switching current up to 750 mA per channel or up to 1.2 A on four channels. Each channel also features channel-to-channel isolation.

  • NI-9485 , 8-Channel, SSR Relay, 60 VDC/30 Vrms, 750 mA C Series Relay Output Module

    779600-01 - NI

    The NI-9485 allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices. Each channel provides access to a solid state relay (SSR) for switching voltages up to 60 VDC/30 Vrms with switching current up to 750 mA per channel or up to 1.2 A on four channels. Each channel also features channel-to-channel isolation.

  • Multi-Operational Surge Tester

    MB Model - PJ Electronics, Inc.

    Bench all-in-one versatile Multi-Operational Surge Tester that you need for all of your electrical insulation testing. The Hi-Pot tester has separate L.E.D. panel meters for direct readout (voltage and leakage current) so that no interpolation on the scopes display is ever needed. This MOST can surge test extremely low inductance windings, DC armatures, etc.

  • Digital Panel Mount Load Cell Meter

    MODEL DPM-3 - Transducer Techniques, Inc

    The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.

  • Power Quality Analyzer

    PQM-703 - Sonel S.A.

    Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.

  • USB PD Power Supply/Module ATS

    8000 Series - Chroma ATE Inc.

    The USB 3.1 specifications has three major features which are 10Gbit/s transmission speed, USB PD (Power Delivery) with support for 100 watt charging power, and the standard Type-C connector/cable that can be inserted with either side. It is expected to meet all kinds of data / video transfer applications. The advent of USB PD may consolidate the specifications of various power converters and the laptop, monitor, printer or Hub that implements USB PD is no longer a simple power-consuming device but able to supply power to other devices. The USB PD DRP (Dual role port) function allows the built-in USB PD module to deliver a maximum of 100 watts of power through the Type-C interface. To make sure the USB PD Type-C output power does not supply invalid voltage or poor power output characteristics with excessive noise that can damage the power consuming device and cause unsuccessful startup, each USB PD power supply or module has to be fully tested during production to ensure the product features meet the design specifications. This ensures high-quality products are provided to the market to gain acceptance.

  • Arduino CAN Shield

    IFB-10003-INP - Playing With Fusion Inc

    CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!

  • Arduino CAN Shield

    IFB-10003-ANP - Playing With Fusion Inc

    CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!

  • Arduino CAN Shield

    IFB-10003-AWP - Playing With Fusion Inc

    CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!

  • Arduino CAN Shield

    IFB-10003-IWP - Playing With Fusion Inc

    CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!

  • Large Earth Resistance Tester

    WA 180 - Wuhan Sangao Electrical Test Installations Limit Co.

    WA180 Type Large earth resistance tester,To test substation earthing network(4Ω), Hydroelectric and Thermoelectric Power Plant,microwave(10Ω),lighting rod(10Ω)etc.Using new type variable frequency AC power supply, And adopts microcomputer control and signal processing measures, Solved the problem of interference of the testing process, To simplify the test procedure, To improve the precision and accuracy of the test results, reducing test personnel's the labor intensity and the cost of testing.The instrument can be used to test all kinds of power frequency earth resistance,contact voltage,step voltage etc frequency power parameters and soil resistivity. The instrument adopts the different frequency Anti-interference resistance technology, under strong interference environment accurately measured the frequency under 50Hz data.The maximum test current is 5A,it will not cause the earth device potential too high,and it also has strong anti interference ability, so it can be measured in the case of non power.

  • AC and DC Electronic load

    63800 series - Chroma ATE Inc.

    The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing thereby giving reliable and unbiased test results. The 63800's state of the art design uses DSP technology to simulate non-linear rectified loads with its unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability. Comprehensive measurements allow users to monitor the output performance of the UUT. Additionally, voltage & current signals can be routed to an oscilloscope through analog outputs. The instrument's GPIB/RS232 interface options provide remote control & monitor for system integration. Built-in digital outputs may also be used to control external relays for short circuit (crowbar) testing.

  • Automatic Three Phase Transformer Ratio Meter

    ATRM PLUS - Eltel Industries

    *Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.

  • POLAR ENERGY

    4BAAA - Elcontrol Energy Net S.r.l.

    Polar Energy (the successor of the Elcontrol VIP 396 energy analyzer) is a multifunctional panel (96 x 96 mm) mounted tool, ideal for remote measurement, display and remote monitoring of electrical quantities.It features a 128×128 graphic display of great visibility and comfortable frontal buttons for direct consultation and setup. It has a wide range of electrical measurements.Compared to the predecessor VIP396, it adds many functionalities that make Polar Energy a modern and user-friendly tool for the user such as the introduction of cyclic connection verification to make installation easy and secure.The connections to the power cables and to the cables of the voltages and currents are carried out via the 2.5 mm2 terminals in the back of the instrument.For the calibration of the currents, it is necessary to use three TAs with a secondary 5 A.It can be used on single-phase, two-phase, three-phase low and medium voltage networks. Advanced features and included analysis software make it an ideal tool for the most demanding professional needs.