  • Digital (1kV up) H.V. Insulation Testers

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines

    SP-RS485-12V-O - Network Technologies Inc

    Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.

  • VME Bus Tester

    VBT100 - Silicon Control Inc.

    The VBT100 has been designed to withstand and measure excessive voltages on both signal and power supply pins. This capability allows it to operate in faulty backplanes that could damage other boards. The tester also detects, measures and identifies which signals have excessive voltages so they can be repaired before boards are loaded into a backplane.

  • Cable Test Van

    BAUR Transcable 4000/S 70-3 - BAUR Prüf- und Messtechnik GmbH

    Transcable 4000/S 70-3. The transcable 4000 70 kV 3/S cable test van varies in comparison with the transcable 32 kV - 3S in the 70 kV voltage level. The system is controlled with the MGS semi-automatic control unit. The high voltage switch unit is 3-phase, air and solid matter insulated and safe to touch.

  • Precision Source / Measure Unit (1 Ch, 100 FA)

    B2901B - Keysight Technologies

    The Keysight B2901B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.

  • Precision Source / Measure Unit, 1-Channel, 10 FA Resolution, 210 V, 3 A DC / 10.5 A Pulse

    B2911B - Keysight Technologies

    The Keysight B2911B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.

  • Precision Source / Measure Unit (2 Ch, 10 FA)

    B2912B - Keysight Technologies

    The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.

  • Precision Source / Measure Unit (2 Ch, 100 FA)

    B2902B - Keysight Technologies

    The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.

  • Standard Digital Multimeter - Auto Ranging

    MM39 - Martindale Electric Co. Ltd

    The MM39 is an auto-ranging multimeter with a large rotary switch for easy selection of the required test, even when wearing gloves. There are two test buttons, one to lock the range and the other to hold the results which are displayed on a 3½ digit LCD screen.

    The main test functions are AC voltage and DC voltage and current and resistance. The MM39 measures both AC and DC voltage between 0.1mV to 600V and AC and DC current between 10mA to 10A. There is a diode test and an audible continuity test which sounds at less than 25Ω.

  • VFD Dual-display 4 1/2-digit Digital Multimeter

    Shenzhen Chuangxin Instruments Co., Ltd.

    Digital multimeter TH1941 4 1/2-digit is voltage/ current /resistance tester with multi functions and  low cost. The  instrument can stably perform measurement at high speed as  several  times  as other instruments  at the same level. It provides excellent  performance, such as maximum reading of  12,000 counts, maximum DC voltage accuracy of 0.02%, and low cost to give you a best choice. Having VFD dual-display with high brightness.  TH1941can synchronously display measurement parameters,  such as AC/DC voltage or current, AC voltage/current and frequency to improve measurement efficiency and display results  clearly.

  • Chroma LCR Meters

    Chroma Systems Solutions, Inc.

    Some of the key features to look for in an LCR meter (also known as an impedance meter) are: accuracy, test frequency, measured parameters, test voltage and test current. Additionally, an easy to understand display of test results and the ability to access and use these results has become increasingly important. Component testing often requires much more than simply a resistance, capacitance or inductance value at a given test frequency and stimulus voltage. An LCR meter or impedance meter must have the flexibility to provide multi-parameters over wide frequency and voltage ranges.

  • High Accuracy Digital Puncture Tester

    KT-5000Pi - Kast Eng Co. LTD.

    This product improves the absurdity that the existing Puncture Tester has many errors between the indicated voltage on its meter and the real output voltage, and also that one cannot check how much current flows during test, and then attaches a voltage meter and a current meter. Its accuracy is high due to Digital method adopting a three point adjustment type. Also, for user's convenience and for making easy to connect with automation line, many input, output functions are added. Now, Puncture Tester also should be accurate and a high-grade product

  • Digital (1kV up) H.V. Insulation Tester

    2803 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.

  • Digital (1kV up) H.V. Insulation Tester

    2804 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.

  • High Performance High Power DC Electronic Load

    IT8900A/E Series - I-TECH Electronic Co., Ltd

    IT8900A/E series high performance high power DC electronic load provides three voltage ranges 150V/600V/1200V, stand-alone power from 2kW to 54kW. IT8900A/E series, with ultra-wide voltage and current range, controlled by an independent master unit. The power expands to 384kW by master-slave paralleling. Ultra-high power density, 6kW is with only 4U height. IT8900A/E series has eight (A series) / four (E series) working modes, faster loop response and current rising and falling speed, as well as dynamic mode, OCP test, OPP test, automatic test and battery test functions. Built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, etc., IT8900A/E series has full protection function, which can be applied to power battery discharge, DC charging station, on-board charger (OBC), power electronics and other power electronics products.