Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 2296 - 2310 of 6609 items found.

  • High Side Current Sense Amp

    QA150 - QuantAsylum

    The QA150 makes ultra-low current measurements of your toughest real-time projects a snap. The QA150 is a high side current to voltage converter. Simply tap into the supply for your various project rails (5V, 3.3V, etc) and the QA150 will convert the currents to voltages that you can then capture on your scope, along with whatever other signals you might need. If you are trying to squeeze every last bit of energy from your batteries, the QA150 is your answer.

  • Power Conditioning

    Measurlogic

    Having a solid power conditioning solution in place before you experience a sag or interruption in power will help you maximize your overall system reliability. Measurlogic provides an array of voltage sag and interruption support solutions for proactive power quality issue prevention. Our DPI and VDC solutions help facilities mitigate future losses due to power quality issues, including lost production time, damaged products, and maintenance after a voltage disruption.

  • Partial Discharge Measuring System

    PD - Shanghai Jiuzhi Electric Co., Ltd.

    Partial discharges (PD), as defined by IEC60270, are localized dielectric discharges in a partial area of a solid or liquid electrical dielectric insulation system under high-voltage field stress. It can be caused by discontinuities or imperfections in the insulation system. PD testing thus gives an indication of deterioration of the insulation and is an indicator of incipient faults. In general PD will occur in systems operating at voltages of 3000 V and above; it should be noted though that in some cases PD can also occur at lower voltages.

  • VAW Meters (Performance Test)

    Premier Electrosystems

    VAW meters indicate the voltage, current, wattage among other parameters that are crucial for testing of any product.Introduction of composite Volt-Amp-Watt Meters by Premier Electrosystems in 1985 has been a runaway success; mainly due to their performance and reliability. Premier Electrosystems have been the pioneers of multi parameter meters i.e. Voltage, Current, Wattage, Kilo Watt hour, Frequency, Power Factor, Run hour, Load hour, 13 level THDs in a single meter

  • Isolation Amplifier

    Dr. Hubert GmbH

    Isolation amplifiers are indispensable components for signal conditioning. There are several reasons that make galvanic potential isolation necessary. Examples for this are personal protection, on the one hand, as required in medical engineering to ensure contact of persons with life-threatening voltages. On the other hand, different safety aspects, such as protection of IT systems may require the use of an isolation amplifiers. If ground loops need to be separated or if a small differential voltage with a high common-mode level must be determined, the isolation amplifier is the device of your choice.

  • Temperature Rise Test Panel

    2000A - SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).

  • Digital RCD/RCCB/GFC/ELCB Tester

    4112 EL - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.

  • Coupling Decoupling Network for Communication Lines

    CDN61000-5C - Lisun Electronics Inc.

    • Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments

  • Gigavac Power Contactors, Switches & Fuses

    Sensata Technologies

    All high power relays, power contactors, and DC disconnect switches are designed and manufactured at our state of the art factory in Carpinteria, California. GIGAVAC’s extensive line also includes compact high voltage relays and high voltage reed relays for specialized DC and RF application requirements. With an engineering staff of thirty plus we can also provide special modifications to meet your every need. Looking for a relay distributor or contactor distributor? GIGAVAC invests in having inventory to provide most products from stock or within a short lead-time. You can purchase high voltage relays, DC contactors, manual disconnect switches, or other GIGAVAC products from one piece to thousands directly from GIGAVAC, your source for Advanced Switching Solutions.

  • Trip Amplifiers

    Datexel

    Datexel manufacture a large range of Trip Amplifiers and Process Limit Alarms that accept universal inputs and provide either relays or NPN or PNP transistor outputs. The DAT5028 is also an isolated signal converter and has a local display with up to 4 relays and is DIP switch programmable. The inputs can be Thermocouples, RTD, mV, mA, Resistance, Potentiometers or Voltage. They can be supplied fully configured set up by PC or DIP switches. The DAT5024 is a trip Amplifier / Temperature limit alarm for RTD's, Thermocouples, Voltage, Resistance and Current with the option of 1 or 2 relay outputs hysteresis and delay timers. The DAT5024 E range is an economical choice with DIP Switch programmable for voltage or current input. Either 1 relay or 2 relays (SPDT) are available with delay timers.

  • High Precision Pointer Multimeter

    KT3201 - Ketai instrument (kunshan) Ltd.

    KT3201 KT3202 KT3203 KT3204 four high-precision multimeters are specially designed for European student watches.It has AC and DC voltage, DC current, resistance, capacitance, continuity, and diode measurement functions.Comply with safety standard CAT III 600V Fuse Φ6x31mm 600VKT3202 is a specially designed AC and DC voltmeter.KT3203 is a specially designed AC and DC ammeter .KT3204 is a specially designed DC low-current, low-voltage meter. The voltage can be measured from 0 to 100mV, and the current can be measured from 0 to 50uA.The pointer "0" is at the median value, and the voltage and current are divided into two sides.This set of four tables has certain practical significance for students' knowledge and understanding of Ohm's law in electrical engineering.This set of meters complies with the CAT III 600V standard.

  • Battery Impedance Meter

    Alpha Lab, Inc.

    Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.

  • Bench Power Supply, Single, Adjustable, 1 Output, 1 V, 60 V, 250 mA, 1.6 A

    72-8340A - Tenma

    The 72-8340A is a 100W switching mode laboratory grade Power Supply with current limiting control, is designed with the objectives of high accuracy, compactness and easy portability. 4 digit display LCD of voltage and current for high precision. The slim tower housing makes it ideal for tight work bench. It is light and conveniently portable with a collapsible handle. The large and illuminated LCD display provides clear and sharp readings even under dim light. The output power on off switch allows safe and handy operations. The tracking OVP (output over voltage protection) ensures a better and tighter protection to voltage sensitive loads. It has good line and load regulations, high efficiency, low ripple and noise that are typical of advanced switching mode power supply.

  • 100W Dual Output Power Supply Two 35V, 1.4A or 60V, 0.8A

    E3649A - Keysight Technologies

    Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)

  • Battery Tester

    CS-3001 - G. Jost -Electronic

    The CS-3001 test system records all block voltages, total voltage and current during a discharge test. The modular design makes it easy to connect most of all battery installations, starting from a single block and ending up with 960 block voltages. Up to four parallel strings can be tested. All measuring modules are electrically isolated (600VDC CAT III, 5000VAC test voltage).

Get Help