Showing results: 3301 - 3315 of 6593 items found.
-
Fiberinthebox
Cable Fault Locator is a device used for short circuit faults, cable cuts, resistive faults, intermittent faults, and sheath faults. Fiberinthebox supply cable fault locator for power cable, optical fiberal cable, etc. Fault Location in Power Cable is designed to locate cable faults, pinpointing the fault location, route tracing, cable identification, voltage withstand test and cable information management. It can locate all kinds of cable faults for all voltage level cables, including open circuit, short circuit, low insulation, high insulation and flashover faults, etc. Most power cables were buried underground, invisible, and out of reach, with modern new power cable fault locater, it can find the fault point quickly, solve problems immediately and restore power supply.
-
-
DCS025 -
Teledyne LeCroy
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
DAS1800 -
B&K Precision Corporation
The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).
-
SL1068B -
Keysight Technologies
The Measurement & Control Module SL1068B is a rack-mount measurement module which provides voltage outputs for analog signaling – useful e.g. for the emulation of temperature sensors or the controlling of regulation vents with voltage input with 8 channels. The module can be used either as a stand-alone device or as extension for a Scienlab Battery Test System.
-
8008 -
VECTOR Electronics and Technology, Inc.
Pad-Per-Hole & Planes 2 Sides. Unique circuit pattern features full voltage & ground planeson both sides with isolated plated-thru holes. 0.080” diameter, isolated solder pad around holes oncomponent side. Plane surfaces solder-coated for user convenience. SMD cap positions for discrete decoupling capacitors.
-
DCP-BTA -
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Weschler Instruments
These switchboard meters and edgewise meters provide a bright, easy to read display of current, voltage, power or other process parameters. Use visible setpoints to quickly show process status. Order optional relay outputs for alarms or control. Models and sizes are available to replace most popular analog instruments. Made in USA.
-
HH2099 -
Colluck Company Limited
3-1/2 digil Large LCD display 2000 count with symbolic signs. CAT II 600V rated. Basic accuracy 0.5%. Auto Ranging High Voltage test up to 600V DC and 600V AC. Higher Current test up to 1000A AC/DC. Measure Resistance up to 20MΩ
-
PeakTech Prüf- und Messtechnik GmbH
A data logger for DC voltages from 0 V to 30 V with terminals on the top of the device. With the included software, all desired parameters can be set before recording, e.g. the desired measurement rate, the start function, the time and date or a password to protect the measured data. The recorded measured values can be evaluated with the PC software.
-
Model 344 -
TREK, INC.
The Trek Model 344 is a precision electrostatic voltmeter for making noncontacting surface voltage measurements in the range of 0 to ±2 kV DC or peak AC. Industrial applications include radiation effect studies, R&D of the electrophotographic processes, and charge accumulation monitoring of the semiconductor production process.
-
CAT-H Series -
Amperis sl
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel
-
Osborne Transformer Corp.
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
HH2102 -
Colluck Company Limited
Basic Accuracy 1.0%. LCD display 2000 count, 12.8mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Signal Injection and Diode test