Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 4501 - 4515 of 6594 items found.

  • Megohmmeters/Insulation Resistance Testers

    AEMC Instruments

    Full line of megohmmeters with test voltages 50V to 5000V. Capability to measure insulation resistance up to 10T. These rugged, weather resistant meters are accurate, reliable and built to perform. Battery, AC Powered & Hand-cranked models available.

  • DWV/IR Test Systems

    Applied Relay Testing Ltd.

    When used in conjunction with ART's own parametric relay test systems such as the RT290, the RT900 offers high speed AC and DC Hipot (dielectric withstand voltage) and Leakage testing of relays or other multi-pin passive devices.

  • CAT IV 600 A TRMS Navigator Clamp Meter

    ACD-50NAV - Amprobe Test Tools

    ACD-50NAV clamp-on power meter offers AC current measurements to 600 A, AC/DC voltage to 1000 V, and wide jaws to accommodate large conductors. This clamp-on multimeter is ideal for industrial power monitoring and verifying system conditions.

  • Environmental Control System (ECS) Tester

    H301 - Howell Instruments, Inc.

    The H301 Environmental Control System (ECS) Tester measures and displays parameters required to test and troubleshoot aircraft heating and air conditioning systems. These parameters include temperatures, pressures, AC and DC voltages, DC currents, and resistances.

  • Rail Traction Inverter Test System

    Electromechanica, Inc.

    The rail inverter test system uses a pulse test methodology to verify proper operation of the IGBT switching elements in a subway car motor control. The system is designed to verify proper commutation of the switching elements. A large capacitor bank allows testing at DC voltages up to 1kV and peak currents of up to 3kA into reactive loads.The system also integrates self test capabilities and safe-to-turn-on (STTO) diagnostics to ensure no gross faults are present prior to the application of high voltages. Further the system includes dielectric withstand (hi-pot) test capability to ensure electrical safety.

  • EIS Battery Analyzer

    BA8100 - B&K Precision Corporation

    The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.

  • Insulation Resistance Measurement

    MD 10KVR - Scope T&M Pvt, Ltd.

    The digital insulation tester model MD-10KVR is Megabras' cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market. A powerful software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 10 TΩ, with 4 pre-selected test voltages, 500 V - 5 kV - 10 kV - 15 kV. Other test voltages may be selected in steps of 25 V, 100 V or 500 V.

  • Insulation Resistance Measurement

    MD 15KVR - Scope T&M Pvt, Ltd.

    The digital insulation tester model MD-15KVR is Megabras' cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market. A powerful software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 15 TΩ, with 4 pre-selected test voltages, 500 V - 5 kV - 10 kV - 15 kV. Other test voltages may be selected in steps of 25 V, 100 V or 500 V.

  • Insulation Resistance Measurement

    MD 5KVr - Scope T&M Pvt, Ltd.

    The digital insulation tester model MD5KVR is TENTECH's cutting edge insulation analyzer equipment and it is one of the most complete and sophisticated available in the international market. A software allows for further analysis of tests results, including features such as graphical representation and automatic report generation. Its proven technology provides safe, reliable and accurate measurements of insulation resistances up to 5 TΩ, with 4 preselected test voltages, 500 V -1 kV - 2,5 kV - 5 kV. Other test voltages, from 50 V to 5 kV, can be selected in 25 V or 500 V steps.

  • 60A True RMS AC Clamp Meter + NCV

    Extech MA61 - Extech Instruments Corporation

    The MA61 is an AC current clamp with NCV voltage detector and full overload protection. Manual ranging clamp meter with three Current ranges and AC/DC voltage to 600V. The 6000mA range allows for low current measurements that may be used in the automotive industry. Unique VFC (variable frequency control) mode helps troubleshoot and diagnose HVAC applications that are variable frequency driven. The MA61 also features resistance, capacitance, frequency, diode and continuity measurements as well as data hold low battery indicator, and auto power off functions. Complete with test leads, carrying case, and two AAA batteries.

  • 60A True RMS AC/DC Clamp Meter + NCV

    Extech MA63 - Extech Instruments Corporation

    The MA63 is an AC/DC current clamp with NCV voltage detector and full overload protection. Manual ranging clamp meter with three Current ranges and AC/DC voltage to 600V. The 6000mA range allows for low current measurements that may be used in the automotive industry. Unique VFC (variable frequency control) mode helps troubleshoot and diagnose HVAC applications that are variable frequency driven. The MA63 also features resistance, capacitance, frequency, diode and continuity measurements as well as data hold low battery indicator, and auto power off functions. Complete with test leads, carrying case, and two AAA batteries.

  • Single-Functional Testers

    3122 - Metrel d.d.

    The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains integrated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS / FAIL lights and help screens for each measurement make the handling of the instrument easy and clear. All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing.

  • HV Power & Transient Isolators

    B-1020-C - ROSS ENGINEERING CORPORATION

    These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.

  • Fiber Optic Transmission Systems

    B-1020-B - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation has developed a HV compact analog fiber optic transmitting and receiving system, with optional over-voltage limiting, designed to drive instrumentation from a DC to 1MHz signal source. The system is available with optional multiple input and output ranges of ±0-1V PK, 0-5V PK to 0-10V PK. It will also operate in conjunction with Ross Engineering Corporation’s high accuracy high voltage wideband voltage dividers, which are useful from DC to over 10MHz up to 1,000,000V PK at 0.01% to 3% accuracy. Transmitters and receivers can be powered by either AC or DC.

  • Battery Discharge and Capacity Testers

    HD Power Test Equipment Co.ltd

    HDFD Battery Discharge Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current. When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.This tester system is simple, safe and accurate for monitoring voltage of cells adopting wireless connection.

Get Help