Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 6166 - 6180 of 6609 items found.

  • Circuit Breaker Test Equipment

    IBEKO Power AB

    DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.

  • Digital Sensors

    PMA-Series - Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Digital Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available to fit any application, including germicidal requirements, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Digital Sensors if you prefer to plug into our PMA-Series Radiometers to read the output of the sensor on the meter’s display. Digital models are typically used as discrete sensors that are portable and located to provide short term information. (By contrast, please select Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information.)

  • Radio Frequency Cable Tester

    RFCT - Textron Systems

    Textron Systems’ Radio Frequency Cable Tester (RFCT) allows for on-site testing and maintenance for radio frequency (RF) transmission paths within a platform. Using preconfigured databases of sweep parameters and pass/fail criteria, the RFCT quickly determines the status of installed RF cables. The RFCT checks each cable’s performance characteristics to include voltage standing wave ratio (VSWR), insertion loss (IL), phase and phase matching. If a cable fails a test, the RFCT automatically determines the distance-to-fault (DTF). With its intuitive touchscreen-based user interface and lightweight, ruggedized packaging, the RFCT is the gold standard for operational-level RF cable testing.

  • Professional Floor Certification Kit

    PFC-252 - Prostat Corporation

    The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within ±5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.

  • Programmable AC Power Source

    Model 8600 Series - Aplab Limited

    - Compact size and light weight, standard 19″ rack construction- Step-less frequency setting from 45 to 450Hz- Very low distortion sine wave output- Output voltage range selectable 135 or 270V AC- Galvanically isolated input/output- Independent on/off switch for input and output- 16×2 vacuum florescent display for parameter display- Complete operation through push switches and a digital rotary encoder- Automatic protection against overload, short circuit and over temp.- Built in PFC to provide 0.99 input power factor and wide input range- Conforms to EN55022, class A, safety standard EN60950

  • 903 Benchtop Three Phase 40A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.

  • Random Access Monochromator

    DeltaRAM X - HORIBA, Ltd.

    The patented DeltaRAM™ X microscope Illuminator is the ideal fluorescence illuminator for quantitative intracellular ion research. It utilizes a galvanometer-based Random Access Monochromator (RAM) that can switch between any wavelength in 2 milliseconds. The DeltaRAM™ X is a complete, self-contained, illuminator that includes a power supply, high intensity xenon light source, DeltaRAM™ X monochromator, TTL shutter and flexible liquid light guide. The wavelength position is a simple analog voltage control. All you need to add is a microscope adapter for your fluorescence microscope and a USB or PCI DAC interface depending on the software you will be using to drive the illuminator.

  • Multifunctional Meter

    CPM-80 - Chuan Sheng Electronics Co., Ltd.

    CPM-80 multifunction power analyzer provide high accuracy single phase and three-phase energy measuring and displaying, energy accumulating, power quality analysis, data logging and data communication. CPM-80 series meters are able to measure bidirectional, four quadrants kWh and kVarh. It provides maximum/minimum records for power usage and power demand parameters. Hardware standard built in a RS485 Modbus communication port , 4 Digital inputs, 2 Relay outputs, LCM and 2MB flash for data-logging. In addition , also provide TOU , voltage and current THD, harmonics up to the 63rd and auto wiring change via software .

  • Dynamic Digital I/O with Per Channel Programmable Logic Levels and PMU PXI Card

    GX5295 - Marvin Test Solutions, Inc.

    The GX5295 offers outstanding digital test capabilities and channel density in a compact 3U PXI form factor. Offering both performance digital and analog test capabilities, the GX5295 provides a cost-effective, tester per pin architecture - making this card the ideal choice for high throughput, mixed-signal component test applications. Each digital channel can be individually programmed for a drive hi, drive lo, sense hi, sense lo, and load value (with commutation voltage level). In addition, each channel offers a parametric measurement unit (PMU) providing users with the capability to perform parallel DC measurements on the DUT (device under test).

  • One, Two, or Four Dual Redundant Interface MIL-STD-1553A/B Test & Simulation Module for PXI Express

    PXIe-1553 - Avionics Interface Technologies

    1, 2, or 4 dual redundant MIL-STD-1553 bus interfaces Concurrent BC, multiple RT (31), and BM operations Full error injection and detection • Data capture filtering, 100% bus recording, and physical bus replay Multi-level Trigger for Capture/Filtering IRIG-B Time Encoder/Decoder Real-Time Recording and Physical Bus Replay Application interfaces supporting C, C++, C#, and .NET development Device Driver Support for: Windows, Linux, and LabVIEW Real Time (others provided on request) 10 high voltage (up to 30V) programmable DIO lines Flight Simulyzer GUI Analyzer software

  • 64-bit PXI Extension Card

    52906 - Chroma ATE Inc.

    The function of PXI extension card is to extend the PXI backplane signal outside of the chassis. Inserting the PXI card to extension card can easily check or measure the PXI card's signal under power on condition, which resolves the problems of inconvenient inspection due to the PXI card inside the chassis for RD or maintenance personnel. PXI extension card is able to isolate the voltage and signals sent to the PXI card for hot swap when the system is powered on. Every time the extension card activates it can supply the power required for PXI initialization. It eliminates the need for rebooting PC when users read and re-write the configuration files.

  • AC Source

    AFV-P - Intepro Systems

    Intepro’s AFV-P Series is a programmable AC/DC output power source with precision measurement and control. This compact power source comes in four power levels, 600VA, 1250VA, 2500VA and 5000VA, providing clean power with distortion less than 0.3% at 40-100Hz. The AFV-P series delivers output voltage from 0 to 310VAC and frequency from 40 to 500Hz or 15 to 1000Hz with the high frequency option. It is ideal for commercial, defense and aerospace test applications from design verification, quality assurance, ATEs. The AFV-P Graphical Users Interface software makes it easy to setup complex testing of the AC input to the UUT.

  • DC Electronic Load

    63600 series - Chroma ATE Inc.

    Chroma's 63600 series DC electronic loads are designed for testing multi-output AC/DC power supplies, DC/DC converters, chargers, batteries, server power supplies, and power electronic components. They are excellent for research, development, produc t ion, and incoming inspection applications. The 63600's state of the art design uses DSP technology to simulate non-linear loads using a unique CZ operation mode allowing realistic loading behavior. The 63600 series can draw its rated current under very low voltage (0.4V typical). This unique feature guarantees the best loading performance for modern Point-of-Load conditions and fuel cells.

  • Dual Nav/Comm Test Panel

    TA-155 - Tech-Aid Products

    The Best Dual Nav/Comm Test Panel on the market today. This panel is designed to test the KX155/155A and KX165/165A radios specifically as well as others and will allow by the book testing of these units. The panel includes specific switching for testing the intercom features, providing unit configuration and audio isolation as required. This panel also incudes basic provisions to run a second Nav/Comm using the long time standard 8 pin octal connector. Monitoring of either current or voltage to either radio is also provided. Integrated or stand alone testing of your OBS or converter indicators is provided as well as the required test jacks. Click on picture for larger view.

  • Materials Lab XM

    Ametek Scientific Instruments

    The Materials Lab XM product provides a fully integrated reference grade time domain and AC measurement platform. No need to switch sample connections between techniques. Time domain measurements include I-V (current voltage) characterization as well as fast pulse techniques. AC testing techniques include everything from single-sine analysis, to multisine / Fast Fourier Transform for faster low frequency analysis, to harmonics and intermodulation for testing linearity and breakdown of materials. Measurements of electrical impedance spectroscopy (EIS), admittance, permittivity and capacitance are all provided from the XM-studio MTS software platform, together with integrated equivalent circuit analysis functionality.

Get Help