Showing results: 3376 - 3390 of 6590 items found.
-
HH2102A -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 21mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Signal injection and Diode test
-
EB-51 -
Ceibo Inc.
# Emulates 80C51 Microcontrollers and Derivatives# Real-Time Operation up to 40 MHz# 3.3V or 5V Voltage Operation# Source-Level Debugger for C, PLM and Assembler# DOS and MS-Windows Software# Support for ROMless and ROMed Microcontrollers# 64K of Code and 64K of Data Memory# Data Memory with Mapping Capabilities# Performance Analyzer# Real-Time and Conditional Breakpoints
-
HH2202 -
Colluck Company Limited
High Accuracy (Basic Accuracy 1.0%). Jumbo LCD display 4000 count, 21mm figure height. Convenient Auto Ranging. Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 40MΩ. Diode test, audible continuity check
-
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
MPR2 Series -
Entes Elektronik
Dimensions:DIN4 kVArh, Max, Min: available (available)% THD I: none (none) % THD V: none (none)Harmonics 1-51.: RS-485: none (none)Digital Input:Digital Output:Temperature Input:AOV:RLY: Memory:Current Voltage Unbalances: none (none) X5/X1: none (none)Plug & Meter: available (available) 85-300 VAC/DC: available (available)
-
Pickering Interfaces Ltd.
a 32-channel Digital I/O card with high output voltage and current capability and a dual variable threshold input. Each of the 32 channel outputs can be used to drive the output high or low using a high current capacity drive capable of sourcing 0.4A from the high side or 0.5A sink on the low side for each channel.
-
8012e -
Sealevel Systems, Inc.
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
ST150 With Diffractive Lens -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that delivers a very low Temperature Coefficient of Responsivity of -0.04%/C with a high output voltage, 19.5 FOV and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package and has a very short thermal shock response to ambient temperature change.
-
FSWT -
Rohde & Schwarz GmbH & Co. KG
The R&S®FSWT is the right tool for detecting compromising emanations. With two equivalent, switchable RF inputs, up to 500 MHz measurement and analysis bandwidth and two analog outputs for video voltage and demodulators, the R&S®FSWT fits perfectly into typical test setups and easily replaces older instruments.
-
Unitech Scales And Measurements Pvt. Ltd
L.D.R. Trainer comprises of light dependent resistor (LDR) fitted to the shaft, which moves inside the tube where lamp is fitted at the other end. Variable DC voltage source is provided to vary the light intensity. Digital indicator is supplied to measure the light intensity in terms of distance moved between LDR and light source.
-
40-614C-006 -
Pickering Interfaces Ltd.
This 4-bank, 32-channel, 1 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-017 -
Pickering Interfaces Ltd.
This 1-bank, 32-channel, 4 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-009 -
Pickering Interfaces Ltd.
This 4-bank, 4-channel, 8 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-002 -
Pickering Interfaces Ltd.
This 16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
HSL-DO32-DB-N -
ADLINK Technology Inc.
*Slave ID consumption: 2 - N: for 32-CH NPN sinking type outputs*Photo couple isolation voltage: 2500Vrms*Output switching capacity: Single channel 500mA; all channels 60mA at 24VDC*Output response time:ON OFF: 180µs, OFF ON: *1.2µsTerminal Base:HSL-TB64 or HSL-TB32U-DIN